Milwaukee MI490 Peroxide Photometer for Food and Olive oil Production

ElectrochemicalSKU: MI490

Precio:
$ 811.14

Gastos de envío calculados en la caja

Descripción

The Milwaukee MI490 Photometer features manual zero point calibration and fast operation in a rugged design.

The Milwaukee Photometer is ideal for users in food and olive oil production applications. This meter is also ideal for educators that want their students to learn the basics of olive oil quality analysis to apply in the real world .

The Milwaukee MI490 Photometer offers:

SPEED
The MI490 microprocessor delivers fast results with accuracy of ±0.5 meq O2 / kg and is repeatable.

EASY TO USE AND TOUGHNESS
This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI490 ideal for everyone from educators, quality lab professionals to olive oil producers and growers.

DESIGN FEATURES
Fast easy to read results with large digital LCD readout.
Accurate to ±0.5 meq O2 / kg and a range 0.0 to 25.0 meq O2 / kg.
Lightweight, ergonomic and portable.
Easy measurement: just mix the oil in the vial sample, gently shake, insert the cuvette, zero the meter then mix the reagents and read.
Simple easy reagent vials.
Easy 1-2-3 instruction steps.
Auto shut off after 15 minutes of non-use, 4 x 1.5 volt AA bateries (batteries included).
Adaptation of the CE n. 2568/97 Method.
BUILT IN TIMER
MI490 has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.

CUVETTE CHAMBER
The MI490 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

ERROR MESSAGING
The MI490 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include light high, light low, inverted sample procedure, overrange readings and zero cal error to ensure the user has the most accurate error free readings.

CALIBRATION
The MI490 has a simple to use zero point calibration. Simply insert the Perioxide reagent vial with 1 mL of oil sample into the chamber after shaking, index the cuvette and press the zero button. Your calibration is complete.