{"title":"UniTrend Instruments","description":null,"products":[{"product_id":"ut-p41-dc-100-khz-100a-ac-dc-current-probe","title":"UT-P41 DC-100 kHz 100A AC\/DC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100kHz bandwidth, 100A AC\/DC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P41_User_Manual.pdf\"\u003eUT-P41 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530159355,"sku":"190500100106X","price":595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P41_1_sq.jpg?v=1790709334"},{"product_id":"ute9802-600v-20a-true-rms-ac-dc-digital-power-meter","title":"UTE9802+ 600V\/20A True RMS AC\/DC Digital Power Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE9802+\u003c\/strong\u003e is a compact single-phase digital power meter measuring 3V – 600V \/ 0.5mA – 20A to 1W – 12kW. It measures in AC, DC and AC+DC true-RMS modes, so a single instrument covers rectified, mixed and DC-bus measurement that an AC-only meter cannot.\u003c\/p\u003e\n\u003cp\u003eIt is built for bench and in-rack power measurement on power-supply, converter and appliance-energy work, with RS-232 and RS-485 for datalogging and integration into automated test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE9800+ Series\u003c\/h2\u003e\n\u003cp\u003eThe UTE9800+ name covers three distinct compact power meters. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eWhat Sets It Apart\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eV \/ A Range\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9802+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC \/ DC \/ AC+DC True RMS\u003c\/td\u003e\n\u003ctd\u003eTrue power, V, A, W, PF, Hz\u003c\/td\u003e\n\u003ctd\u003e3V – 600V \/ 0.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9806+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApparent power + V \/ PF alarm limits\u003c\/td\u003e\n\u003ctd\u003eV, A, P, VA, PF, Hz, Vpeak, Apeak\u003c\/td\u003e\n\u003ctd\u003e0.5V – 600V \/ 0.05mA – 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9811+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50th-order harmonic analysis (PLL)\u003c\/td\u003e\n\u003ctd\u003eV, A, W, PF, Hz, THD, CF\u003c\/td\u003e\n\u003ctd\u003e3V – 600V \/ 5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe three UTE9800+ models are not a progression — each is a distinct instrument chosen by what you need to measure: mixed-mode true RMS (9802+), limit\/alarm testing (9806+), or harmonic and distortion analysis (9811+).\u003c\/p\u003e\n\u003cp\u003eFor single-phase high-voltage bench measurement or three-phase work, see the UTE310 Series (600 V \/ 1000 V single-phase) and the UTE323 Series (3-channel three-phase) — distinct higher-tier instrument lines.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eAC \/ DC \/ AC+DC true-RMS measurement modes\u003c\/li\u003e\n\u003cli\u003eTrue power, V, A, W, PF and frequency\u003c\/li\u003e\n\u003cli\u003e3V – 600V \/ 0.5mA – 20A measurement range, to 1W – 12kW\u003c\/li\u003e\n\u003cli\u003eVoltage resolution 0.01V; current resolution 0.1mA\u003c\/li\u003e\n\u003cli\u003eMeasurement bandwidth DC, 40Hz – 400Hz\u003c\/li\u003e\n\u003cli\u003eRS-232 and RS-485 for datalogging and ATE integration\u003c\/li\u003e\n\u003cli\u003e4.3-inch LCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE9802+ Details\u003c\/h2\u003e\n\u003ch3\u003eAC \/ DC \/ AC+DC True-RMS Measurement\u003c\/h3\u003e\n\u003cp\u003eThe UTE9802+ measures in three modes — AC, DC and AC+DC true RMS. A single instrument covers an AC line, a DC bus and a rectified or mixed waveform, where an AC-only meter would mis-read the DC and composite cases.\u003c\/p\u003e\n\u003ch3\u003eRS-232 \/ RS-485 Communication\u003c\/h3\u003e\n\u003cp\u003eBoth RS-232 and RS-485 are standard, with SCPI and Modbus support, for datalogging and integration into multi-drop production-line monitoring or an automated test framework.\u003c\/p\u003e\n\u003ch3\u003eCompact Bench \/ In-Rack Form Factor\u003c\/h3\u003e\n\u003cp\u003eThe compact chassis fits a test bench or an instrument rack and leaves the front-panel reading clear for V, A, W, PF and frequency at a glance during a measurement run.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eMixed-Mode Power Measurement\u003c\/h3\u003e\n\u003cp\u003eAC, DC and AC+DC true-RMS modes measure rectified outputs, DC bus rails and mixed waveforms on converter and power-supply work where an AC-only meter falls short.\u003c\/p\u003e\n\u003ch3\u003ePower-Supply \u0026amp; Converter Bench Test\u003c\/h3\u003e\n\u003cp\u003eTrue power and power factor on SMPS and DC\/DC outputs support efficiency and loading measurement at the bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables and the UTE-M01-US North-American test fixture support safe connection to standard plug loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does the UTE9802+ differ from the other UTE9800+ models?\u003c\/h3\u003e\n\u003cp\u003eEach UTE9800+ model is a distinct instrument: the UTE9802+ adds AC\/DC\/AC+DC true-RMS modes, the UTE9806+ adds apparent power and limit alarms, and the UTE9811+ adds 50th-order harmonic analysis. They are chosen by measurement need, not as a tier progression.\u003c\/p\u003e\n\u003ch3\u003eDoes it have a computer interface?\u003c\/h3\u003e\n\u003cp\u003eYes — RS-232 and RS-485 with SCPI and Modbus support, for datalogging and automated test.\u003c\/p\u003e\n\u003ch3\u003eIs this a three-phase meter?\u003c\/h3\u003e\n\u003cp\u003eNo. The UTE9800+ models are single-phase (1P2W). For three-phase measurement, see the UTE323 Series.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE9802+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3V – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC, 40Hz – 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC \/ DC \/ AC+DC (True RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV, A, W, PF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=64\"\u003eUTE9802+ Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eRS232 Cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530093819,"sku":"182700700014X","price":313.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTE9802_-1.png?v=1790709335"},{"product_id":"ut-p31-100-mhz-100-1-1000-1-differential-oscilloscope-probe","title":"UT-P31 100 MHz 100:1\/1000:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100 MHz differential oscilloscope probe (100:1\/1000:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100:1\/1000:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1500Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P31_User_Manual.pdf\"\u003eUT-P31 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530290427,"sku":"190500300015","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P31_1_sq.jpg?v=1790709334"},{"product_id":"ut-p42-150-khz-200a-ac-dc-current-probe","title":"UT-P42 150 kHz 200A AC\/DC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e150kHz bandwidth, 200A AC\/DC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P42_User_Manual.pdf\"\u003eUT-P42 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601529962747,"sku":"190500100133X","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P42_1_sq.jpg?v=1790709334"},{"product_id":"ut-p21-50-mhz-1000-1-high-voltage-oscilloscope-probe","title":"UT-P21 50 MHz 1000:1 High Voltage Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e50MHz (-3dB) high-voltage passive probe (1000:1 attenuation) for measuring power supply rails, inverters, and high-voltage circuits up to several kV. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz (-3dB) Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC 15kV \/ AC 10kV rms Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eΦ75mm×340mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC 15kV \/ AC 10kV rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 pF-50 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P21_User_Manual.pdf\"\u003eUT-P21 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530323195,"sku":"190500300013","price":430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P21_1_sq.jpg?v=1790709335"},{"product_id":"udp1306c-1ch-192w-32v-6a-programmable-linear-dc-power-supply","title":"UDP1306C 1Ch 192W 32V\/6A Programmable Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UDP1306C is a single-channel programmable linear DC power supply delivering 0–32 V at 0–6 A — 192 W of clean DC from a value-tier instrument. The 32 V ceiling and 6 A current capability cover most service-shop and bench needs (powering boards under repair, driving solenoids and small motors, sourcing test current for relay coils, validating regulated subsystems against their input rails), and the linear topology keeps output ripple under 2 mVrms.\u003c\/p\u003e\n\u003cp\u003eAn auxiliary fixed 5 V \/ 2 A output handles logic-side power on a board under test while the main channel sources the load — useful when characterizing a regulated subsystem against its input rail. SCPI over USB-Device or RS-232 lets the UDP1306C join an automated test setup at the same control reach as the higher-tier UDP3000C three-channel platform; five preset storage groups, shutdown memory, and a Digital I\/O hardware ON\/OFF pin pair round out the workflow set.\u003c\/p\u003e\n\u003cp\u003eFor industrial maintenance, equipment service, single-rail bench work, teaching labs, and DIY\/hobbyist electronics where one programmable rail at 6 A is the right answer, the UDP1306C is the value-tier point in UNI-T's linear PSU lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP1306C_1.jpg\" alt=\"UNI-T UDP1306C 1Ch 192W programmable linear DC power supply, front view\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAcross the Design. Debug. Deploy.™ Lifecycle\u003c\/h2\u003e\n\u003cp\u003eThe UDP1306C fits the workflow we call \u003cstrong\u003eDesign. Debug. Deploy.\u003c\/strong\u003e — the three-act cycle most engineering teams actually run a power supply through. In \u003cstrong\u003eDesign\u003c\/strong\u003e, five preset storage groups and shutdown memory let a planned voltage profile execute repeatably while the rest of the bench attends to capture and analysis. In \u003cstrong\u003eDebug\u003c\/strong\u003e, OVP\/OCP\/OTP protections, the auxiliary 5 V \/ 2 A logic-side rail, and three-window 4-digit V\/I readout make it safe to push a marginal load and see exactly what's happening at the terminals. In \u003cstrong\u003eDeploy\u003c\/strong\u003e, SCPI over USB-Device or RS-232 means the same supply that ran on the design bench can drop into a production rack or service station and be controlled by the same scripts. One instrument, three phases, no relearning.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e0–32 V \/ 0–6 A single-channel main output\u003c\/strong\u003e — 192 W rated. The 32 V ceiling covers automotive and industrial 24 V rails with margin; the 6 A capability handles most single-rail bench work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary fixed 5 V \/ 2 A output\u003c\/strong\u003e — independent rail with its own short-circuit and over-voltage protection. Powers logic-side circuits while the main channel drives the load under test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear topology, ≤2 mVrms ripple\u003c\/strong\u003e — pass-element regulation. Load regulation ≤0.01% + 3 mV in CV mode. Clean for low-noise analog work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI programmable\u003c\/strong\u003e — USB-Device + RS-232 with full SCPI command set, same control reach as the higher-tier UDP3000C platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 mV \/ 1 mA setting resolution\u003c\/strong\u003e — three-window 4-digit V\/I display (set value \/ output value \/ selectable third readout).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVP \/ OCP \/ OTP protection\u003c\/strong\u003e — configurable thresholds plus over-temperature shutdown. Auxiliary 5 V \/ 2 A rail has independent short-circuit and over-voltage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive preset storage groups\u003c\/strong\u003e — save and recall full instrument states for fast bench setup. Shutdown memory restores last settings on power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware output ON\/OFF via Digital I\/O\u003c\/strong\u003e — back-panel pin pair for external interlock circuits, panic buttons, or test-fixture safety integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-panel 5 V \/ 2 A USB-A charging port\u003c\/strong\u003e — independent USB-A receptacle for charging a phone or powering a USB device. Charging only — the SCPI data interfaces are USB-Device and RS-232 on the back panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeypad lock + output setting viewable\u003c\/strong\u003e — lock the front-panel keys to preserve a known-good test condition; view stored setpoints without disturbing the live output.\u003c\/li\u003e\n\u003cli\u003eIntelligent cooling fan — load- and temperature-controlled; quiet at light load.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch2\u003eSingle-Channel Linear at the Value Tier\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eLinear pass-element regulation, single adjustable channel, 0–32 V at 0–6 A, 192 W — built for general-purpose bench work, industrial maintenance, equipment service, teaching labs, and DIY\/hobbyist electronics. 6 A on a single rail covers most service-shop power needs (powering boards under repair, driving solenoids and small motors, sourcing test current for relay coils), and the linear topology keeps output ripple under 2 mVrms — clean for low-noise analog work that doesn't need the higher-tier UDP3000C platform.\u003c\/p\u003e\n\u003cp\u003eThree-window 4-digit voltage and current display (set value, output value, and a selectable third readout) keeps the instrument legible across the bench. 10 mV \/ 1 mA setting resolution. Constant-voltage and constant-current modes with automatic crossover. Load regulation ≤0.01% + 3 mV in CV; ≤0.1% + 10 mA in CC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP1306C_3.jpg\" alt=\"UDP1306C front-panel three-window display showing voltage and current readout\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSCPI Control Over USB-Device or RS-232\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP1306C_2.jpg\" alt=\"UDP1306C back panel showing USB-Device, RS-232, and Digital I\/O interfaces\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe UDP1306C carries the same SCPI command interface as the UDP3000C platform: back-panel USB-Device and RS-232 ports, with a Digital I\/O pin pair for hardware ON\/OFF remote control. For test-fixture integration on a service bench, automated burn-in stations, and small-batch production test, SCPI gives the same automation reach as higher-tier UDP3000C-platform supplies.\u003c\/p\u003e\n\u003cp\u003eVoltage and current setpoint, OVP\/OCP threshold, output enable, memory recall, and readback are all accessible from a host script. Five preset storage groups keep frequently used configurations available for fast recall under SCPI. The Digital I\/O ON\/OFF pin pair enables external interlocks and safety circuits without needing software intervention.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAuxiliary 5 V \/ 2 A Output and Front-Panel USB Charging\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UDP1306C carries two fixed-voltage 5 V \/ 2 A outputs in addition to the main adjustable channel — and they're not the same rail.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eauxiliary 5 V \/ 2 A output\u003c\/strong\u003e is a screw-terminal rail on the back panel for wiring into the DUT. It has its own short-circuit and over-voltage protection on the rail itself, so a fault on the logic side won't take down the main bench supply. Use it to power logic-side circuits on a board under test while the main 0–32 V channel sources the regulated rail you're tuning.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003efront-panel 5 V \/ 2 A USB-A charging port\u003c\/strong\u003e is a USB-A receptacle for charging a phone, powering a USB-powered device, or running a USB lamp on the bench. Charging only — no data lines. The SCPI data interfaces are USB-Device and RS-232 on the back panel, distinct from this charging port.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP1306C_4.jpg\" alt=\"UDP1306C front panel detail showing main channel terminals and USB-A charging port\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eOVP \/ OCP \/ OTP Protection\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThree independent protections cover the most common ways a load fails: a short or low-impedance fault drives current up (OCP), a misconfigured DUT pulls voltage out of spec (OVP), or a sustained over-load heats the supply itself (OTP). All three trip the output off and display a fault state on the front panel.\u003c\/p\u003e\n\u003cp\u003eOVP and OCP thresholds are user-configurable via the front-panel keys. OTP is internal and not user-configurable. The auxiliary 5 V \/ 2 A rail has independent short-circuit and over-voltage protection on the rail itself, separate from the main channel's OVP\/OCP — meaning a logic-side fault on the auxiliary rail does not affect the main channel and vice versa.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/UDP1306C_1_sq.jpg\" alt=\"UDP1306C protection display indicators on front panel\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFive Preset Storage Groups and Hardware ON\/OFF\u003c\/h2\u003e\n\u003cp\u003eFive preset storage groups save and recall the full instrument state — voltage setpoint, current setpoint, OVP and OCP thresholds, output enable. Recall is a single front-panel keypress; the SCPI command set exposes the same recall under remote control. \u003cstrong\u003eShutdown memory\u003c\/strong\u003e restores the last operating state on power-up: a clean line-cycle interruption resumes operation at the prior settings, useful when a bench needs to come back online without manual reconfiguration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHardware ON\/OFF via Digital I\/O.\u003c\/strong\u003e The back-panel Digital I\/O pin pair enables external control of the output state — TTL-level input toggles the main channel on or off without needing software involvement. Useful for external interlocks (panic-button kills the output before software can react), test-fixture safety integration (DUT cover open ⇒ output off), and any scenario where output state needs to follow a hardware signal.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eIndustrial Maintenance and Equipment Service\u003c\/h3\u003e\n\u003cp\u003eSingle-channel 0–32 V \/ 6 A covers most service-shop power needs: powering boards under repair, driving solenoids and small motors, sourcing test current for relay coils, validating regulated subsystems. The 32 V ceiling and 6 A current capability handle 24 V-rail equipment with headroom; SCPI integrates the supply into existing test fixtures and burn-in stations. The auxiliary 5 V \/ 2 A output handles logic-side power on a board under repair while the main channel sources the rail being tested.\u003c\/p\u003e\n\u003ch3\u003eDIY Electronics and Hobbyist Workshops\u003c\/h3\u003e\n\u003cp\u003eProgrammable linear supply at the price point hobbyist budgets allow. The auxiliary 5 V \/ 2 A output handles logic-side power on the board you're building while the main channel sources the rail you're tuning. The 32 V ceiling covers higher-voltage prototypes that 30 V supplies clip against. Front-panel USB charging port powers a logic analyzer, multimeter, or any USB-powered bench accessory without needing a separate wall-wart.\u003c\/p\u003e\n\u003ch3\u003eTeaching Labs and Trade Schools\u003c\/h3\u003e\n\u003cp\u003eSingle-channel programmable supply at a per-station cost that lets a teaching lab equip a 20-bench classroom inside budget. Five preset storage groups let a single instrument support multiple lab exercises without manual reconfiguration each session.\u003c\/p\u003e\n\u003ch3\u003eSmall-Batch Production Test\u003c\/h3\u003e\n\u003cp\u003eProgrammable single-rail supply at a price point that allows deploying multiple instances on a small-batch production line. SCPI over USB-Device or RS-232 scripts the test sequence; the auxiliary 5 V \/ 2 A output handles logic-side power on the unit under test while the main rail drives the load. Hardware Digital I\/O ON\/OFF supports panic-button and interlock integration on test fixtures.\u003c\/p\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003cp\u003eEvery UDP1306C ships with the instrument, a region-specific power cord, a USB communication cable, output cables, an English user manual, and a factory calibration certificate.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUDP1306C instrument\u003c\/li\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB communication cable\u003c\/li\u003e\n\u003cli\u003eOutput cables\u003c\/li\u003e\n\u003cli\u003eEnglish user manual\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eShips from authorized US dealer.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eUDP1306C vs UDP6700 \/ UDP6900B — linear vs switching, when to choose which?\u003c\/h3\u003e\n\u003cp\u003eThe UDP1306C is linear; the UDP6700 and UDP6900B series are switching. The choice is mostly about ripple and noise floor versus efficiency and current-rating-per-dollar.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose linear (UDP1306C)\u003c\/strong\u003e when low ripple and clean noise floor matter more than power density — analog circuit work, audio, low-noise sensor characterization, anything where ≤2 mVrms output ripple is worth the trade-off in size and weight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose switching (UDP6700)\u003c\/strong\u003e when you need higher rated power per chassis dollar and the load is digital or insensitive to switching noise — industrial maintenance with mid-current loads, automotive subsystem testing, motor-drive bench work. UDP6700 also offers wide-range power-ratio-3.0 envelopes that linear topologies cannot match.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose UDP6900B\u003c\/strong\u003e when the bench needs LAN with web control, USB-Host, RS-485 with Modbus, slope mode, auto-range, multi-machine daisy-chain, and a built-in DVM in addition to high-current switching output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's the difference between the UDP1306C and the UDP3303C?\u003c\/h3\u003e\n\u003cp\u003eChannel count and form factor. The UDP1306C is a single-channel value-tier instrument (1 main adjustable + 1 fixed 5 V \/ 2 A auxiliary). The UDP3303C is a three-channel UDP3000C-platform supply (CH1 + CH2 adjustable + CH3 logic-rail selector). Choose UDP1306C if you need one programmable rail at this price point; choose UDP3303C if you need the multi-channel CH3 logic-rail flexibility on the higher-tier platform.\u003c\/p\u003e\n\u003ch3\u003eDoes the UDP1306C have LAN?\u003c\/h3\u003e\n\u003cp\u003eNo. The UDP1306C's data interfaces are USB-Device and RS-232 only. The Digital I\/O pin pair on the back panel handles hardware ON\/OFF — useful for external interlocks but not for data communication. For LAN with LXI\/web interface, the UDP3000S series adds it on the higher-tier multi-channel linear platform.\u003c\/p\u003e\n\u003ch3\u003eWhat is the auxiliary 5 V \/ 2 A output for, and how is it different from the front-panel USB charging port?\u003c\/h3\u003e\n\u003cp\u003eThe auxiliary 5 V \/ 2 A output is a fixed-voltage rail on screw terminals at the back panel — for wiring into the DUT to power logic-side circuits while the main 0–32 V \/ 6 A channel sources the rail you're tuning. The auxiliary rail has its own short-circuit and over-voltage protection on the rail itself, so a fault on the logic side won't take down the main bench supply. The front-panel 5 V \/ 2 A USB-A port is a separate, independent receptacle for charging a phone or powering a USB device — charging only, no data lines. They are two different physical outputs at the same nominal voltage.\u003c\/p\u003e\n\u003ch3\u003eCan the UDP1306C run automated voltage sweeps?\u003c\/h3\u003e\n\u003cp\u003eYes — SCPI control over USB-Device or RS-232 supports remote voltage and current setpoint commands plus readbacks. Five preset storage groups keep frequently used configurations available for fast recall. For complex programmable waveform output (list mode and trigger delayer), the UDP3000S series and the switching UDP6700\/UDP6900B series add those capabilities.\u003c\/p\u003e\n\u003ch3\u003eWhy is the rated output power 192 W if 32 V × 6 A = 192 W?\u003c\/h3\u003e\n\u003cp\u003e192 W is the rated output power, which equals the maximum simultaneous voltage × current product the supply can deliver continuously on the main channel. The 32 V ceiling and 6 A ceiling are the individual maxima; the supply can deliver any voltage\/current combination inside the 192 W envelope, including 32 V at lower currents or 6 A at lower voltages. The auxiliary 5 V \/ 2 A rail (10 W) is independent of the main channel's 192 W budget; the front-panel USB charging port (also 5 V \/ 2 A, 10 W) is a third independent output and likewise does not draw from the main channel's budget.\u003c\/p\u003e\n\u003ch3\u003eWhat's included in the box?\u003c\/h3\u003e\n\u003cp\u003eInstrument, region-specific power cord, USB communication cable, output cables, English user manual, factory calibration certificate. Ships from authorized US dealer.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePart of UNI-T's linear DC power supply lineup. See also UDP3303C (multi-channel linear) and all UNI-T DC power supplies.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–32 V \/ 0–6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V \/ 2 A fixed (with short-circuit and over-voltage protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Main-Channel Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront-Panel USB Charging Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V \/ 2 A USB-A (charging only, no data lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProgramming Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetting Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV: 10 mV \/ I: 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetting Accuracy (25 °C ± 5 °C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV: ≤0.5% + 20 mV \/ I: ≤0.5% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eRegulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV: ≤0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI: ≤0.1% + 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Regulation (CV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV: ≤0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Regulation (CC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI: ≤0.1% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (20 Hz–20 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV: ≤2 mVrms \/ I: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤300 ppm\/°C (V\/I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise\/Fall Time Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤100 ms (10% rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay \u0026amp; Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-window 4-digit voltage and current high-precision display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 preset storage groups + shutdown memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOVP, OCP, OTP, keypad lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary 5 V \/ 2 A Rail\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent short-circuit and over-voltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device, RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O hardware ON\/OFF pin pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ 5 V \/ 2 A (front panel, USB-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Input \u0026amp; Cooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 \/ 120 \/ 220 \/ 230 V ±10%, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntelligent fan (load- and temperature-controlled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 × 194 × 327 mm (5.35 × 7.64 × 12.87 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kg (16.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eECCN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3A992.a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=35\"\u003eUDP1306C Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530061051,"sku":"181730080298X","price":282.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UDP1306C_Cables.jpg?v=1790709335"},{"product_id":"ut673pv-solar-pro-mppt-pv-meter","title":"UT673PV Solar Pro MPPT PV Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT673PV is a purpose-built solar diagnostic that finds a panel's maximum power point and reads the numbers that tell you whether it's performing: maximum power from 5 W to 800 W, open-circuit voltage and peak-power voltage from 12 V to 60 V, and short-circuit and peak-power current from 0 A to 35 A. It connects through integrated MC4 connectors and is powered by the panel under test — no batteries to charge.\u003c\/p\u003e\n\u003cp\u003eA manual MPPT test, a data-hold function, and a large color LCD make field readings quick, and built-in protections (reverse polarity, overvoltage, overcurrent, overtemperature, overpower) guard the meter in real installations. The compact 143 × 74 × 25 mm body fits a pocket. It's backed by UNI-T's nearly 40 years of test-meter manufacturing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum power measurement 5 W to 800 W, ±(1.0%+10)\u003c\/li\u003e\n\u003cli\u003eOpen-circuit voltage and peak-power voltage 12 V to 60 V\u003c\/li\u003e\n\u003cli\u003eShort-circuit and peak-power current 0 A to 35 A\u003c\/li\u003e\n\u003cli\u003eManual maximum-power-point (MPPT) test\u003c\/li\u003e\n\u003cli\u003eBattery-free — powered by the panel under test\u003c\/li\u003e\n\u003cli\u003eIntegrated MC4 connectors, no adapters needed\u003c\/li\u003e\n\u003cli\u003eData-hold function; large color LCD\u003c\/li\u003e\n\u003cli\u003eReverse-polarity, over-voltage\/current\/temperature\/power protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT673PV Details\u003c\/h2\u003e\n\u003ch3\u003eMaximum Power Point on the Spot\u003c\/h3\u003e\n\u003cp\u003eThe UT673PV runs a manual MPPT test to find where a panel delivers its most power, reading maximum power from 5 W to 800 W. That single figure tells you quickly whether a panel or string is performing or losing output to shading, soiling, or degradation.\u003c\/p\u003e\n\u003ch3\u003eThe Full PV Picture\u003c\/h3\u003e\n\u003cp\u003eBeyond peak power, the meter reads open-circuit voltage and short-circuit current (12–60 V, 0–35 A) — the values that diagnose a panel against its nameplate and pinpoint why output is low.\u003c\/p\u003e\n\u003ch3\u003eBattery-Free, MC4-Ready\u003c\/h3\u003e\n\u003cp\u003ePowered directly by the panel under test, the UT673PV never needs charging, and integrated MC4 connectors plug straight into standard solar leads without adapters — practical for moving down a string in the field.\u003c\/p\u003e\n\u003ch3\u003eProtected \u0026amp; Pocketable\u003c\/h3\u003e\n\u003cp\u003eReverse-polarity, overvoltage, overcurrent, overtemperature, and overpower protection guard the meter in real installations, and a 143 × 74 × 25 mm body with a data-hold function keeps it quick and portable.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eSolar PV installation commissioning; panel and string performance checks; preventive-maintenance and O\u0026amp;M surveys; and incoming or quality inspection of photovoltaic modules.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eDoes the UT673PV need batteries?\u003c\/h3\u003e\n\u003cp\u003eNo — it is powered directly by the solar panel being tested.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat does it measure?\u003c\/h3\u003e\n\u003cp\u003eMaximum power (5–800 W), open-circuit and peak-power voltage (12–60 V), and short-circuit and peak-power current (0–35 A), plus a manual MPPT test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eHow does it connect to panels?\u003c\/h3\u003e\n\u003cp\u003eThrough integrated MC4 connectors, so it plugs into standard solar leads without adapters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Power (Pmax)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 800 W, ±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax-Power Current (Imp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 35 A, ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax-Power Voltage (Vmp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 60 V, ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen-Circuit Voltage (Voc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 60 V, ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Current (Isc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 35 A, ±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eColor LCD (52 × 66 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBacklight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual MPPT Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Hold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowered by solar panel (no battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e143 × 74 × 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT673PV_datasheet.pdf\"\u003eUT673PV Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT673PV_User_Manual.pdf\"\u003eUT673PV User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530224891,"sku":"182701100002X","price":59.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UNI-T_UT673V_3_sq.jpg?v=1790709335"},{"product_id":"uts5026a-26-5-ghz-performance-series-signal-analyzer","title":"UTS5026A 26.5 GHz Performance-Series Signal Analyzer","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"panel\"\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch1\u003eUNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTS5026A Performance-Series Signal Analyzer\u003c\/strong\u003e covers \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e in a single instrument, with \u003cstrong\u003e-163 dBm\/Hz displayed average noise level\u003c\/strong\u003e (typical, with the UTS5000A-P26 preamp option) and \u003cstrong\u003e-107 dBc\/Hz typical phase noise\u003c\/strong\u003e at 1 GHz, 10 kHz offset. Total absolute amplitude accuracy is \u003cstrong\u003e±0.40 dB at 50 MHz\u003c\/strong\u003e reference. RBW resolves from \u003cstrong\u003e1 Hz to 8 MHz\u003c\/strong\u003e and the analyzer captures up to \u003cstrong\u003e100,001 sweep points\u003c\/strong\u003e per trace.\u003c\/p\u003e\n\u003cp\u003eUTS5026A is built around three pillars: \u003cstrong\u003efrequency reach\u003c\/strong\u003e through the K-band ceiling at 26.5 GHz, covering all sub-6 GHz cellular and Wi-Fi bands plus 5G mmWave-adjacent spectrum, SATCOM downlinks, and microwave point-to-point links; a \u003cstrong\u003equiet front end\u003c\/strong\u003e with -163 dBm\/Hz typical DANL (P26 option) and -107 dBc\/Hz typical phase noise that resolves low-level spurs and characterizes oscillator skirts cleanly; and a \u003cstrong\u003emodular measurement library\u003c\/strong\u003e covering vector signal demodulation, I\/Q capture, EMI pre-compliance, 5G NR and LTE air-interface decoding, dedicated phase-noise measurement, and analog AM\/FM demodulation — each available as a no-expiration license unlock. Engineered for RF and microwave design teams, EMC pre-compliance benches, cellular and SATCOM development groups, and private-sector test labs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e spectrum measurement — covers sub-6 GHz, K-band, and microwave point-to-point bands in one instrument\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDANL: -163 dBm\/Hz typical\u003c\/strong\u003e (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW); -150 dBm\/Hz typical baseline (preamp off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise: -107 dBc\/Hz typical\u003c\/strong\u003e at 1 GHz, 10 kHz offset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal absolute amplitude accuracy: ±0.40 dB at 50 MHz\u003c\/strong\u003e reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRBW: 1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e, plus 4, 5, 6, 8 MHz wide-band settings; selectivity \u0026lt;4.1 : 1 nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSweep points: up to 100,001\u003c\/strong\u003e per trace; counter resolution 0.001 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrace detectors:\u003c\/strong\u003e Normal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum safe input:\u003c\/strong\u003e +27 dBm average \/ +47 dBm peak (gated)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e15.6-inch 1920×1080 multi-touch HD capacitive display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional licenses:\u003c\/strong\u003e VSA (digital demod), I\/Q analyzer, EMI pre-compliance, 5G NR \/ LTE FDD \/ LTE TDD demod, AMA (analog AM\/FM), PNM (phase noise), AMK (advanced measurement kit), P26 (preamp gain)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e RF input (NMD 2.92 mm), 10 MHz Ext Ref In\/Out (BNC), Ext Trigger In (BNC, TTL), HDMI 1.4, USB-A 3.0 + USB-A 2.0 Host, USB-B 2.0 Device, LAN (VXI11)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree firmware updates\u003c\/strong\u003e and \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTS5026A Detailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e9 kHz to 26.5 GHz Frequency Coverage\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTS5026A spectrum input covers \u003cstrong\u003e9 kHz at the low end and 26.5 GHz at the high end\u003c\/strong\u003e, spanning eleven internal LO frequency bands to maintain calibrated response across the full range. That single-instrument reach removes the need for separate analyzers when work moves between sub-6 GHz cellular spectrum, ISM and Wi-Fi bands, K-band SATCOM downlinks, point-to-point microwave links, and radar IF chains.\u003c\/p\u003e\n\u003cp\u003eFrequency span is selectable from 0 Hz (zero-span time-domain capture) to the full 26.5 GHz range. Sweep time runs \u003cstrong\u003e1 ms to 4,000 s for spans ≥10 Hz\u003c\/strong\u003e, and 1 µs to 6,000 s in zero span for capturing transient events. The 10 MHz internal reference (with ±3×10⁻⁸ temperature stability) ties measurements to a stable timebase, with external 10 MHz reference in\/out on rear-panel BNC for shared-clock instrument racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eSensitivity for Low-Level Signal Detection (DANL -163 dBm\/Hz typ.)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eWeak-signal work — identifying low-level spurs in oscillator output, characterizing leakage from a shielded enclosure, capturing intermittent interference — is rate-limited by how far the analyzer’s own noise floor sits below the signal of interest. UTS5026A reaches \u003cstrong\u003e-163 dBm\/Hz typical DANL\u003c\/strong\u003e in the 20 MHz to 1.5 GHz band \u003cem\u003ewith the UTS5000A-P26 preamp option\u003c\/em\u003e, and \u003cstrong\u003e-160 dBm\/Hz typical\u003c\/strong\u003e across most of the analyzer’s mid-band range with preamp engaged. Without P26, baseline DANL runs \u003cstrong\u003e-145 to -150 dBm\/Hz typical\u003c\/strong\u003e mid-band — competitive for general spectrum work, but P26 is what unlocks the headline number.\u003c\/p\u003e\n\u003cp\u003ePreamp coverage extends from \u003cstrong\u003e100 kHz to 7.5 GHz\u003c\/strong\u003e on the low-frequency band and \u003cstrong\u003e100 kHz to 26.5 GHz\u003c\/strong\u003e on the high band. Maximum safe input is \u003cstrong\u003e+27 dBm average\u003c\/strong\u003e (input attenuation ≥20 dB, preamp on) and \u003cstrong\u003e+47 dBm peak\u003c\/strong\u003e for short-pulse work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003ePhase Noise (-107 dBc\/Hz typ.) for Clean Oscillator Characterization\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe local oscillator’s phase noise is the floor that limits how cleanly the analyzer can resolve close-in spurs, modulation sidebands, and reciprocal mixing artifacts on the device under test. UTS5026A specifies \u003cstrong\u003e-107 dBc\/Hz typical at 10 kHz offset\u003c\/strong\u003e from a 1 GHz carrier, with \u003cstrong\u003e-102 dBc\/Hz at 1 kHz\u003c\/strong\u003e, \u003cstrong\u003e-110 dBc\/Hz at 100 kHz\u003c\/strong\u003e, and \u003cstrong\u003e-132 dBc\/Hz at 1 MHz\u003c\/strong\u003e offset (typical, 1 kHz RBW, 10 Hz VBW, log-average over \u0026gt;50 acquisitions).\u003c\/p\u003e\n\u003cp\u003eFor RF designers characterizing PLL synthesizers, VCOs, and crystal oscillators, that envelope means close-in noise sidebands on the device under test sit above the analyzer’s own contribution rather than buried beneath it. The \u003cstrong\u003eUTS5000A-PNM Phase Noise Measurement option\u003c\/strong\u003e adds a dedicated measurement mode with logarithmic offset axes, jitter calculation, and integration limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRBW Resolution and Selectivity (1 Hz to 8 MHz)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eResolution Bandwidth selects from \u003cstrong\u003e1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e (the standard 10:1 ratio family used across professional spectrum analyzers), plus dedicated \u003cstrong\u003e4, 5, 6, and 8 MHz\u003c\/strong\u003e wide-band settings for fast sweeps over wide spans. Bandwidth accuracy is \u003cstrong\u003e±1.0% (±0.044 dB) nominal\u003c\/strong\u003e from 1 Hz to 750 kHz.\u003c\/p\u003e\n\u003cp\u003eSelectivity (the −60 dB to −3 dB shape factor) measures \u003cstrong\u003e\u0026lt;4.1 : 1 nominal\u003c\/strong\u003e, which lets two adjacent unequal-amplitude carriers resolve cleanly without the smaller signal disappearing into the larger one’s skirt. Video bandwidth tracks the same range, and seven trace detectors cover both general-purpose and standards-specific measurement modes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e100,001 Sweep Points for Fine-Grained Frequency Analysis\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eSweep point count is configurable from \u003cstrong\u003e11 to 100,001 across all spans\u003c\/strong\u003e. At 100,001 points across a 1 GHz span, frequency resolution per trace bin is \u003cstrong\u003e10 kHz\u003c\/strong\u003e — tight enough to localize narrow-band interference, identify specific ITU channel allocations, and walk between adjacent regulatory mask boundaries without interpolation between coarse sweep bins.\u003c\/p\u003e\n\u003cp\u003eMarker resolution scales with the trace span and sweep-point count. A dedicated frequency counter mode tightens uncertainty further, with counter resolution at \u003cstrong\u003e0.001 Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eVector Signal Analysis and I\/Q Capture (UTS5000A-VSA + UTS5000A-I\/Q Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-VSA Digital Demodulation option\u003c\/strong\u003e adds a vector demodulation engine covering \u003cstrong\u003e2 MHz to 26.5 GHz carrier\u003c\/strong\u003e and the major digital modulation formats: \u003cstrong\u003eASK (2-ASK); FSK (2\/4\/8\/16); MSK (GMSK); PSK (BPSK, QPSK, OQPSK, 8PSK); DPSK (DBPSK, DQPSK, D8PSK, π\/4-DQPSK, π\/8-D8PSK); QAM (16, 32, 64, 128, 256)\u003c\/strong\u003e. Symbol rate ranges \u003cstrong\u003e1 ksps to 2.5 Msps\u003c\/strong\u003e, with EVM\/SNR statistics displayed alongside IQ constellation, eye, and time-domain views.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-I\/Q Analyzer option\u003c\/strong\u003e adds direct I\/Q capture and spectrum analysis at \u003cstrong\u003e9 kHz to 25 MHz analysis bandwidth standard (extended to 40 MHz with B40)\u003c\/strong\u003e, with a \u003cstrong\u003e14-bit ADC at 90 MSa\/s\u003c\/strong\u003e capturing up to 4,000,000 IQ sample pairs per acquisition. Window selection covers Flat-top, Uniform, Hanning, Gaussian, Blackman, Blackman-Harris, and Kaiser-Bessel shapes. Together, the two options form the foundation for waveform-level characterization of arbitrary digitally-modulated carriers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Air-Interface Demodulation (UTS5000A-NR \/ FDD-LTE \/ TDD-LTE Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor teams developing 5G New Radio infrastructure, LTE base-station components, or cellular-band devices, three dedicated demodulation licenses extend the analyzer into protocol-aware air-interface measurement: \u003cstrong\u003eUTS5000A-NR for 5G New Radio\u003c\/strong\u003e, \u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e, and \u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e. Each license is a standalone purchase.\u003c\/p\u003e\n\u003cp\u003eCombined with the analyzer’s 26.5 GHz frequency reach, the cellular licenses cover sub-6 GHz LTE and 5G NR FR1 deployments directly, plus 5G NR FR2 mmWave bands at 24.25–26.5 GHz. The instrument’s low phase noise and tight amplitude accuracy translate into clean EVM measurements on the device under test. License unlocks are no-expiration: once added, they remain on the instrument for the life of the unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMI Pre-Compliance to 26.5 GHz (UTS5000A-EMI Option)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-EMI Pre-Compliance Measurement option\u003c\/strong\u003e transforms the analyzer into a CISPR\/EN-class pre-compliance instrument with regulatory limit lines, quasi-peak and average detectors, and band-segmented scan modes. Measurement extends to the analyzer’s full \u003cstrong\u003e26.5 GHz ceiling\u003c\/strong\u003e, covering not just the traditional 30 MHz to 1 GHz radiated-emissions band but also the higher-frequency emissions from 5G transceivers, automotive radar, and microwave data links.\u003c\/p\u003e\n\u003cp\u003eThe companion \u003cstrong\u003eUTS-EMI01 near-field probes kit\u003c\/strong\u003e adds four probe heads spanning 30 MHz to 3 GHz at three resolution scales plus a 5 mm resolution probe to 2 GHz, for localizing radiating components on a populated PCB. Pre-compliance use moves EMI debugging earlier in the development cycle — before the formal test-house chamber visit, when board-level fixes are still cheap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e15.6″ Multi-Touch HD Display and Serviceable Front End\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe front-panel display is a \u003cstrong\u003e15.6-inch 1920×1080 multi-touch capacitive TFT LCD\u003c\/strong\u003e — a deliberate departure from the 7-to-10-inch displays common at this frequency tier. Capacitive multi-touch supports drag-to-pan, pinch-zoom on traces, and gesture-based menu navigation, with the larger display real estate accommodating up to 4-window simultaneous layouts in the VSA and I\/Q modes. The instrument is built for serviceability over the warranty lifetime: a \u003cstrong\u003eremovable dust filter\u003c\/strong\u003e on the air inlet lifts out for cleaning, preventing the dust-accumulation failure mode that limits long-term reliability on cooled bench instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRF and Microwave Design \/ R\u0026amp;D\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor RF and microwave design teams characterizing PLL synthesizers, mixer spurious products, amplifier compression, and front-end module performance, the UTS5026A’s 26.5 GHz reach with -107 dBc\/Hz typical phase noise gives the instrument the headroom to act as the reference measurement on the bench. The 100,001-point sweep resolution, ±0.40 dB amplitude accuracy at 50 MHz, and full SCPI\/LXI remote control make the analyzer a primary fixture in R\u0026amp;D characterization workflows.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Cellular Development\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eWith the UTS5000A-NR, FDD-LTE, and TDD-LTE demodulation licenses, the analyzer covers sub-6 GHz cellular bands plus 5G NR FR2 mmWave allocations in the 24.25 to 26.5 GHz range. Combined with the I\/Q analyzer’s 40 MHz (B40) analysis bandwidth, the instrument supports waveform-level evaluation of base-station transmitters, small-cell units, and cellular-band devices.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMC Pre-Compliance and Production Test Labs\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eProduction characterization labs and EMC pre-compliance benches use the UTS5026A’s combination of 26.5 GHz frequency ceiling, regulatory-grade amplitude accuracy, and the optional UTS5000A-EMI license to run pre-chamber scans across CISPR-band ranges and into 5G transceiver and radar emission bands. Free firmware updates plus no-expiration license unlocks keep the instrument current as standards evolve.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eStandard Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord × 1\u003c\/li\u003e\n\u003cli\u003eUSB cable × 1 (UT-D14)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement option licenses (no-expiration unlock)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-NR\u003c\/strong\u003e — 5G New Radio (NR) demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e — LTE FDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e — LTE TDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-VSA\u003c\/strong\u003e — Digital demodulation (ASK\/FSK\/PSK\/QAM\/MSK\/DPSK) with EVM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-I\/Q\u003c\/strong\u003e — I\/Q analyzer (25 MHz \/ 40 MHz with B40 analysis BW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-EMI\u003c\/strong\u003e — EMI pre-compliance measurement to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMA\u003c\/strong\u003e — Analog AM\/FM demodulation, 2 MHz to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-PNM\u003c\/strong\u003e — Phase Noise Measurement (dedicated mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMK\u003c\/strong\u003e — Advanced Measurement Kit (channel power, ACPR, OBW, T-power, harmonics)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-P26\u003c\/strong\u003e — Preamplifier gain option (unlocks -163 dBm\/Hz typ. DANL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRF cables and connector kits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-CK02 kit\u003c\/strong\u003e — RF cables and connectors: UT-W03-40GHz cable, UT-C04-40GHz adapter, UT-C03-18GHz adapter, UT-W03 SMA-SMB cable, UT-C01 SMA-N adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNear-field probes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS-EMI01 kit\u003c\/strong\u003e — Four near-field probes: NFP-3G-P1 (30 MHz–3 GHz, 10 cm range), NFP-3G-P2 (30 MHz–3 GHz, 3 cm range), NFP-2G-P3 (30 MHz–2 GHz, 5 mm resolution), NFP-3G-P4 (30 MHz–3 GHz, 2 mm resolution)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTS5000A and the UTS3000A series?\u003c\/p\u003e\n\u003cp\u003eThe two analyzers target different work. The \u003cstrong\u003eUTS3000A series\u003c\/strong\u003e covers 9 kHz to 3.6 \/ 6 \/ 8.4 GHz with a \u003cstrong\u003ebuilt-in tracking generator and standard real-time spectrum analysis plus VNA capability (S11 + S21)\u003c\/strong\u003e; it’s the right choice when work involves stimulus-response measurements, real-time transient capture as a standard capability, and characterization below 8.4 GHz.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A (UTS5026A)\u003c\/strong\u003e is a measurement-only analyzer covering \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e with no tracking generator and no VNA. It targets work that needs \u003cstrong\u003efrequency reach above 8.4 GHz\u003c\/strong\u003e — K-band SATCOM, 5G NR FR2 mmWave bands, 24 GHz radar, microwave links — or the deeper option library covering 5G NR \/ LTE demodulation and dedicated phase-noise measurement that the UTS3000A doesn’t offer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich capabilities are standard, and which require optional licenses?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e (included): swept and FFT spectrum analysis from 9 kHz to 26.5 GHz, with all the headline specifications — 1 Hz to 8 MHz RBW, 100,001 sweep points, ±0.40 dB amplitude accuracy at 50 MHz, -107 dBc\/Hz typical phase noise, the full trace-detector set, marker functions, and SCPI\/LAN\/USB remote control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional licenses\u003c\/strong\u003e (each sold separately, no-expiration unlock): UTS5000A-VSA (digital demodulation), UTS5000A-I\/Q (I\/Q analyzer), UTS5000A-EMI (EMI pre-compliance), UTS5000A-NR (5G NR demod), UTS5000A-FDD-LTE and UTS5000A-TDD-LTE (LTE demod), UTS5000A-AMA (analog AM\/FM demod), UTS5000A-PNM (phase-noise measurement), UTS5000A-AMK (advanced measurement kit), and UTS5000A-P26 (preamplifier gain — unlocks the -163 dBm\/Hz typical DANL specification).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTS5026A include a tracking generator or VNA function?\u003c\/p\u003e\n\u003cp\u003eNo. The UTS5026A is a measurement-only signal analyzer — it does not produce stimulus signals. There is no internal tracking generator, no VNA capability, and no S-parameter measurement function. For applications requiring stimulus-response measurements (filter characterization, antenna VSWR, S11 \/ S21), the UTS3000A series provides those capabilities up to 8.4 GHz with a built-in reflection bridge and tracking generator. For frequencies above 8.4 GHz, an external signal generator paired with the UTS5026A in receive-only mode is the typical configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add the UTS5000A-P26 preamplifier option later, after the original purchase?\u003c\/p\u003e\n\u003cp\u003eYes. All UTS5000A optional licenses, including the P26 preamplifier gain option, are \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e that can be added at any time after the original instrument purchase. The hardware to support each option is present in every shipping unit; the license unlocks the firmware functionality. Adding P26 after purchase requires no service-depot return.\u003c\/p\u003e\n\u003cp\u003eThat makes a typical procurement path practical: buy the base instrument, then add P26, VSA, I\/Q, or cellular demod licenses as the project mix evolves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTS5026A remotely programmable?\u003c\/p\u003e\n\u003cp\u003eYes. The UTS5026A supports a complete \u003cstrong\u003eSCPI command set\u003c\/strong\u003e covering every front-panel function, accessible over \u003cstrong\u003eUSB-B 2.0, LAN (VXI-11 over 10\/100\/1000 Base RJ-45)\u003c\/strong\u003e, and through the built-in WebServer interface for browser-based access. The full programming manual ships with the instrument, and the analyzer integrates into ATE racks running NI-VISA, Keysight IO Libraries, or any standards-compliant instrument-control framework, with LXI conventions for network discoverability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 26.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.000000 MHz, ±3×10⁻⁸ stability (20 to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW selectivity (-60 dB \/ -3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4.1 : 1 (-60 dB \/ -3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,001 (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms to 4,000 s (span ≥ 10 Hz); 1 µs to 6,000 s (zero span)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Run, External 1, External 2, Video, Periodic Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp on, with UTS5000A-P26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-163 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp off, baseline)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-150 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (1 GHz, 10 kHz \/ 1 MHz offset)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-107 \/ -132 dBc\/Hz typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal absolute amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.40 dB + frequency response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy at 50 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.40 dB at 50 MHz reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-170 dBm to +30 dBm, 0.01 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 dB, 2 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum safe input (avg \/ peak \/ DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+27 dBm avg \/ +47 dBm peak (gated) \/ +16 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThird-order intercept (TOI, typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+16 dBm typ. (10 MHz to 2 GHz, preamp off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual spurious response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 dBm (200 kHz to 26.5 GHz, swept)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrace detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of traces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 inch, 1920 x 1080, Multi-touch capacitive TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRF input connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 mm male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExt reference in \/ out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz BNC: -5 to +10 dBm in \/ \u0026gt;0 dBm out, 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB \/ LAN \/ HDMI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A 3.0 (front) + USB-A 2.0 (rear) Host; USB-B 2.0 Device; LAN (VXI11) 10\/100\/1000; HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (±10%), 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature \/ humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to +40 °C; ≤90% RH below +35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e445 mm × 311 mm × 195 mm (W × H × D) \/ About 11 kg (24.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications \/ ECCN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus \/ 3A992.a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=93\"\u003eUTS5026A Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUTS5000A-AMA — AM\/FM Analog Demodulation Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-AMK — Advanced Measurement Kit Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-EMI — EMI Pre-Compliance Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-FDD-LTE — FDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-I\/Q — I\/Q Analyzer Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-NR — NR demodulation analysis option for UTS5000A series\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-P26 — Preamplifier Gain Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-PNM — Phase Noise Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-TDD-LTE — TDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-VSA — Digital Demodulation Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530388731,"sku":"181200100024X","price":31499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS5000A-1.png?v=1790709335"},{"product_id":"ut8805e-5-5-digit-performance-series-bench-digital-multimeter","title":"UT8805E 5.5 Digit Performance-Series Bench Digital Multimeter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT8805E Performance-Series Bench Digital Multimeter\u003c\/strong\u003e is a \u003cstrong\u003e5½-digit auto-ranging True-RMS\u003c\/strong\u003e meter with \u003cstrong\u003e0.015% basic DC voltage accuracy\u003c\/strong\u003e, a \u003cstrong\u003e5,000 rdgs\/s\u003c\/strong\u003e maximum reading rate, and a \u003cstrong\u003e199,999-count\u003c\/strong\u003e display on a \u003cstrong\u003e4.3in 480×272 TFT-LCD\u003c\/strong\u003e. SCPI over LAN, RS-232, and USB makes the UT8805E a clean drop-in for automated test setups.\u003c\/p\u003e\n\u003cp\u003eFor R\u0026amp;D measurement and small-lab production test where SCPI automation, \u003cstrong\u003efour-wire (Kelvin) resistance\u003c\/strong\u003e, \u003cstrong\u003edual display\u003c\/strong\u003e, and the full math\/dB\/dBm\/Pass-Fail suite matter, the UT8805E delivers the performance jump from general-purpose bench DMM to instrumented test station. Four display modes (Number, Bar Graph, Trend Graph, Histogram), thermocouple and RTD temperature measurement, and 10,000-reading internal storage are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5½-digit, 199,999-count display\u003c\/strong\u003e — 0.015% basic DC voltage accuracy at the tier price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC measurement\u003c\/strong\u003e — accurate readings on non-sinusoidal waveforms (switching supplies, motor drives, PWM, dimmed loads).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-ranging\u003c\/strong\u003e — across voltage, current, resistance, and capacitance functions, reducing operator workflow friction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5,000 rdgs\/s maximum reading rate\u003c\/strong\u003e — fast acquisition for high-throughput automated test and noise-reduction averaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple and RTD temperature measurement\u003c\/strong\u003e — range -270°C to 1820°C, with built-in cold-end compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-wire (Kelvin) resistance measurement\u003c\/strong\u003e — eliminates lead and contact resistance from low-resistance readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual display\u003c\/strong\u003e — simultaneous viewing of two parameters (e.g., voltage + frequency) without menu toggling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMath, statistics, and Pass\/Fail\u003c\/strong\u003e — max\/min\/average, standard deviation, dB\/dBm, relative, configurable limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour display modes\u003c\/strong\u003e — Number, Bar Graph, Trend Graph, and Histogram.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, RS-232, USB-Host, USB-Device\u003c\/strong\u003e — SCPI command set, VXI-11, USBTMC for full remote-control automation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10,000 readings internal storage\u003c\/strong\u003e — measurement files, instrument setups, and SCPI logs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UT8805E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5½-Digit Display and 0.015% Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe UT8805E delivers a \u003cstrong\u003e5½-digit 199,999-count\u003c\/strong\u003e display with \u003cstrong\u003e0.015% basic DC voltage accuracy\u003c\/strong\u003e. DC voltage resolution reaches \u003cstrong\u003e1μV\u003c\/strong\u003e and DC current resolution reaches \u003cstrong\u003e1nA\u003c\/strong\u003e — meeting the spec floor required for low-signal R\u0026amp;D measurement, transducer-output characterization, and reference-source verification. Resistance measurement resolution is \u003cstrong\u003e0.1mΩ\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/span\u003e\n\n\u003ch3\u003eMeasurement Function Coverage\u003c\/h3\u003e\n\u003cp\u003eMeasurement coverage includes AC\/DC voltage, AC\/DC current, resistance, four-wire resistance, capacitance, diode, continuity, frequency, duty cycle, temperature (thermocouple), period. Capacitance measurement extends to \u003cstrong\u003e2 mF\u003c\/strong\u003e. Frequency counter range is \u003cstrong\u003e20 Hz – 1 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS AC Measurement\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS AC measurement delivers correct readings on distorted, non-sinusoidal waveforms — switching-mode power supply outputs, motor-drive currents, dimmed lighting loads, PWM signals — where an average-responding meter would read low. AC voltage and AC current measurements are both True-RMS.\u003c\/p\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Dual.png\" alt=\"Dual display showing voltage and frequency simultaneously\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDual display showing voltage and frequency simultaneously\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDual Display\u003c\/h3\u003e\n\u003cp\u003eDual display shows two parameters at once — voltage with frequency, current with frequency, or any compatible primary\/secondary pairing — without toggling between menus. For diagnostics on AC sources, switching supplies, and motor drives, this lets you watch the primary measurement and its frequency simultaneously.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Dual.png\" alt=\"Dual display showing voltage and frequency simultaneously\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDual display showing voltage and frequency simultaneously\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMath, Statistics, and Pass\/Fail\u003c\/h3\u003e\n\u003cp\u003eBuilt-in math includes max\/min\/average tracking, standard deviation, relative measurement (REL), dB and dBm operations, and configurable limits. Pass\/Fail comparison automatically flags out-of-tolerance readings and sounds an alarm. All math operations apply across voltage, current, resistance, capacitance, frequency, and temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Math.png\" alt=\"Built-in math: statistics, limits, dB, dBm, and relative operations\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in math: statistics, limits, dB, dBm, and relative operations\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Math.png\" alt=\"Built-in math: statistics, limits, dB, dBm, and relative operations\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in math: statistics, limits, dB, dBm, and relative operations\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Modes.png\" alt=\"Four display modes: Number, Bar Graph, Trend Graph, and Histogram\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour display modes: Number, Bar Graph, Trend Graph, and Histogram\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFour Display Modes\u003c\/h3\u003e\n\u003cp\u003eFour display modes adapt the on-screen presentation to the measurement task: \u003cstrong\u003eNumber\u003c\/strong\u003e for a clean primary reading, \u003cstrong\u003eBar Graph\u003c\/strong\u003e for quick visual go\/no-go interpretation, \u003cstrong\u003eTrend Graph\u003c\/strong\u003e for time-series behavior, and \u003cstrong\u003eHistogram\u003c\/strong\u003e for distribution visualization on repeated samples. Switching is a single-key operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Modes.png\" alt=\"Four display modes: Number, Bar Graph, Trend Graph, and Histogram\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour display modes: Number, Bar Graph, Trend Graph, and Histogram\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e4.3-inch TFT-LCD with 480×272 Resolution\u003c\/h3\u003e\n\u003cp\u003eThe 4.3-inch TFT-LCD displays the full 199,999-count primary reading with secondary parameter and unit annotations at high legibility from typical bench viewing distance. The digitized analog bar graph beneath the primary reading supports rapid trend interpretation when the measurement is changing slowly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8805E-Display.png\" alt=\"4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4.3-inch TFT-LCD with 199,999-count 5½-digit resolution\u003c\/span\u003e\n\n\u003ch3\u003e5,000 rdgs\/s Maximum Reading Rate\u003c\/h3\u003e\n\u003cp\u003eMaximum reading rate is \u003cstrong\u003e5,000 rdgs\/s\u003c\/strong\u003e on the UT8805E. For automated test sequences this means short loop times when stepping through measurement steps under SCPI control. For high-resolution characterization, the same reading rate supports averaging-based noise reduction without slowing the test cadence.\u003c\/p\u003e\n\u003ch3\u003eFour-Wire Resistance\u003c\/h3\u003e\n\u003cp\u003eFour-wire (Kelvin) resistance measurement eliminates lead and contact resistance from low-resistance readings. For shunt resistors, motor windings, contactor coils, PCB-trace resistance, and any measurement below approximately 100 Ω where lead resistance distorts the result, the four-wire path delivers the accuracy the digit count promises.\u003c\/p\u003e\n\u003ch3\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp\u003eTemperature measurement supports thermocouple sensors over the range \u003cstrong\u003e-270°C to 1820°C\u003c\/strong\u003e with \u003cstrong\u003e0.5°C accuracy\u003c\/strong\u003e, plus RTD (thermal-resistance) sensor input for higher-accuracy laboratory measurements. A built-in cold-end compensator is standard, so external reference junctions are not required.\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Remote Control\u003c\/h3\u003e\n\u003cp\u003eFour host interfaces: \u003cstrong\u003eLAN\u003c\/strong\u003e, \u003cstrong\u003eRS-232\u003c\/strong\u003e, \u003cstrong\u003eUSB-Host\u003c\/strong\u003e, and \u003cstrong\u003eUSB-Device\u003c\/strong\u003e. LAN supports VXI-11 for SCPI-over-Ethernet; USB-Device supports USBTMC; RS-232 supports established automated-test scripts and embedded controllers that don't have an Ethernet path. USB-Host accepts a USB flash drive for file import\/export. SCPI command set is IEEE-488.2-style and compatible with the mainstream multimeter command set, easing migration from existing test code.\u003c\/p\u003e\n\u003ch3\u003eSCPI Command Set and Automation\u003c\/h3\u003e\n\u003cp\u003eThe UT8805E accepts SCPI commands compatible with the mainstream multimeter command set, easing migration from existing test scripts. Configuration and triggering via SCPI is supported across all measurement functions. Firmware updates are free over the product's lifetime. Measurement results return as ASCII or numeric blocks per SCPI conventions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Measurement and Characterization\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-resolution DC voltage and current measurement on bench power rails, sensor outputs, and reference circuits.\u003c\/li\u003e\n\u003cli\u003eComponent characterization across voltage, resistance, capacitance, and temperature within a single bench session.\u003c\/li\u003e\n\u003cli\u003eLong-term drift studies with timestamped recording to internal storage and post-test export over USB or LAN.\u003c\/li\u003e\n\u003cli\u003eFour-wire resistance measurement of low-value shunts, PCB traces, and contact resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Automated Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI-driven automated test sequences with reading rates that keep loop times short on multi-DUT lines.\u003c\/li\u003e\n\u003cli\u003ePass\/Fail comparison automatically flagging out-of-tolerance units with audible alarm.\u003c\/li\u003e\n\u003cli\u003eIncoming-inspection batch testing with statistical summary reporting (max, min, average, standard deviation).\u003c\/li\u003e\n\u003cli\u003eIntegration into existing rack-and-stack production environments via LAN (VXI-11) or USB (USBTMC).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalibration and Metrology Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerification of bench instruments against reference standards using the meter's high resolution and accuracy.\u003c\/li\u003e\n\u003cli\u003ePeriodic in-house verification of secondary standards between formal calibration cycles.\u003c\/li\u003e\n\u003cli\u003eRTD- and thermocouple-based thermal characterization with cold-end compensation built in.\u003c\/li\u003e\n\u003cli\u003eLong-duration logging of environmental and reference-source drift for trend analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT8805E benchtop digital multimeter\u003c\/li\u003e\n\u003cli\u003eStandard test lead set\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eUSB-Device cable for PC connection\u003c\/li\u003e\n\u003cli\u003ePC software (included; downloadable from uni-trend.com)\u003c\/li\u003e\n\u003cli\u003eUser manual and factory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-wire test lead set\u003c\/strong\u003e — Kelvin-style test leads for low-resistance measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType-K thermocouple probe\u003c\/strong\u003e — for temperature measurement across the supported range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 19-inch rack mount kit\u003c\/strong\u003e — for rack-integration in production-test and ATE installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8802E\u003c\/strong\u003e — Value-tier 4½-digit manual-range bench DMM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8803E\u003c\/strong\u003e — Classic-tier 3⅚-digit auto-ranging bench DMM with inductance and D\/Q.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8804E\u003c\/strong\u003e — Advanced-tier 4⅚-digit bench DMM with data recording and Pass\/Fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8805E\u003c\/strong\u003e — Performance-tier 5½-digit SCPI bench DMM with four-wire resistance and math. \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806E\u003c\/strong\u003e — Performance-tier 6½-digit SCPI bench DMM (LAN\/RS-232\/USB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806EG\u003c\/strong\u003e — Performance-tier 6½-digit bench DMM with IEEE-488.2 GPIB (substitutes for RS-232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UT8805E compare to other models in the UT8800E series?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E is the entry of the Performance cohort: 5½-digit precision, 5,000 rdgs\/s maximum reading rate, full SCPI automation over LAN\/RS-232\/USB, four-wire resistance, dual display, math\/statistics, and 10,000-reading internal storage. For higher resolution (6½-digit), faster reading rate (10,000 rdgs\/s), and larger storage (32 Gb NAND Flash), step up to the UT8806E. For GPIB connectivity, see the UT8806EG.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat instrument-control libraries does this multimeter support?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E responds to a SCPI command set compatible with the mainstream multimeter command set, with VXI-11 over LAN and USBTMC over USB-Device. It works with pyvisa, industry-standard VISA implementations, LabVIEW Instrument Control, MATLAB Instrument Control Toolbox, and equivalent controllers. RS-232 is also available for established automated-test scripts or embedded controllers without an Ethernet path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UT8805E factory-calibrated, and how often does it need recalibration?\u003c\/p\u003e\n\u003cp\u003eYes — every UT8805E ships with a factory calibration certificate. The recommended recalibration interval is once per year for metrology-traceable measurement applications. For routine workbench use where the meter is being used for relative comparisons or go\/no-go checks against known references, longer intervals are acceptable. Recalibration is performed through Uni-Trend or an accredited third-party calibration laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat probes and accessories ship with the UT8805E?\u003c\/p\u003e\n\u003cp\u003eThe UT8805E ships with the standard probe and lead set appropriate to its measurement range, a power cord, the USB-Device cable for PC connection, the included software disc or download link, a user manual, and the factory calibration certificate. For four-wire (Kelvin) resistance measurement, dedicated four-wire test leads are recommended for low-resistance accuracy and are available as an accessory. Verify the included contents against the packing list on delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Digits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5½ (5.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e199,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic DC Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1nA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Reading Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000 rdgs\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Range (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Hz – 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-270°C to 1820°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFour-Wire Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDual Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath Operations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatistics, Limits, Pass\/Fail, dB, dBm, Relative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480×272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLAN \/ RS-232 \/ USB-Host \/ USB-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Command Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI (VXI-11, USBTMC, IEEE-488.2-style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=27\"\u003eUT8805E Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n  \u003cli\u003eUT8800 series safety instructions attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601529929979,"sku":"180908080072X","price":489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT8805E_Probes.jpg?v=1790709334"},{"product_id":"ut-p35-50-mhz-50-1-500-1-differential-oscilloscope-probe","title":"UT-P35 50 MHz 50:1\/500:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e50 MHz differential oscilloscope probe (50:1\/500:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50:1\/500:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e130VDC+PeackAC \/ 1300VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 1000 V \/ CAT II 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50:1, 500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/50); ≤ 1mVrms (1\/500)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P35_UT-P36_User_Manual.pdf\"\u003eUT-P35 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530421499,"sku":"190500100119X","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P35_1_sq.jpg?v=1790709335"},{"product_id":"utp3305-ii-3ch-335w-32v-5a-linear-dc-power-supply","title":"UTP3305-II 3Ch 335W 32V\/5A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305-II is the precision-grade refresh of UNI-T's UTP3305 platform — the same 335W three-channel linear topology, with a four-digit LED display reading 10 mV \/ 1 mA, tighter regulation specs, and a temperature-controlled cooling fan. Two adjustable channels deliver 0–32V at 0–5A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and a front panel that doesn't require a manual to operate.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms with no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 10A). Load regulation tightens to CV \u0026lt;0.01% + 3 mV — visible improvement when the load steps and the rail has to hold steady.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 335W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–5A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour-Digit LED Display, 10 mV \/ 1 mA Resolution\u003c\/strong\u003e — Per-channel voltage and current readouts that read down to 10 mV and 1 mA — fine enough to actually see what the load is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTighter Regulation\u003c\/strong\u003e — Load regulation CV \u0026lt;0.01% + 3 mV \/ CC \u0026lt;0.2% + 3 mA. Tracking accuracy ±(0.1% of reading + 30 mV).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover\u003c\/strong\u003e — Automatic transition between constant-voltage and constant-current operation when the load steps, with current limit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 10A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature-Controlled Cooling Fan\u003c\/strong\u003e — Fan speed scales with internal temperature. Quiet at light loads, full airflow when the supply is working hard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eThe Precision Upgrade That Costs Almost Nothing\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305-II keeps the operational simplicity of the UTP3305 — knobs, banana jacks, output ON\/OFF — and tightens the parts that matter when your circuit actually responds to the supply. Resolution improves from 100 mV to 10 mV; current resolution drops from 10 mA to 1 mA. Load regulation moves from CV ≤1×10⁻⁴ + 3 mV to CV \u0026lt;0.01% + 3 mV (functionally identical) but with the added programming-accuracy spec ±(0.1% of reading + 30 mV) that the original UTP3305 doesn't publish.\u003c\/p\u003e\n\u003cp\u003eThe temperature-controlled cooling fan is a quality-of-life upgrade that matters in classrooms and small-team R\u0026amp;D rooms: the supply is genuinely quiet at moderate loads, and only spins up when you're actually running it hard. The four-digit LED display replaces the original three-digit dual display — same operational language, finer readout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget, with the precision display students actually need to see what's happening on the rail. Quiet fan operation makes a 30-station lab livable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003e10 mV \/ 1 mA resolution shows the small effects that 100 mV \/ 10 mA hides — supply load lines, sensor bias drift, op-amp quiescent current. Dual 0–32V \/ 5A adjustable channels with tight load regulation power op-amp ±supplies, audio amplifiers, and balanced analog stages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable bench supply for board-level service work with the resolution to set rails accurately and the current capability to drive higher-power loads. CV\/CC auto crossover handles unknown loads safely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMixed-Signal Prototyping\u003c\/h3\u003e\n\u003cp\u003eTwo adjustable rails with master-slave-style behavior in tracking, plus a fixed 5V CH3 for logic, covers most prototyping needs in a single instrument. Linear output stays clean across the full range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3305-II have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. UNI-T's HQ ordering description literally lists this model as \"Non-Programmable Linear DC Power Supply\" — there is no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3305 and UTP3305-II?\u003c\/p\u003e\n\u003cp\u003eThe \"-II\" is the precision-grade refresh of the same 335W \/ 3-channel linear platform: voltage and current resolution improve from 100 mV \/ 10 mA to 10 mV \/ 1 mA, the display moves from 3-digit to 4-digit per channel, and the supply gains a temperature-controlled cooling fan and a published programming-accuracy spec. Output ratings, ripple, and feature set are otherwise comparable. Choose -II for finer readout and quieter operation; choose the original UTP3305 if pricing is the dominant factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3305-II?\u003c\/p\u003e\n\u003cp\u003eThe UTP3305-II ships with the instrument, a power cord conforming to the destination country, test output line, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3305-II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–5A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV \u0026lt;0.01% + 3 mV\u003cbr\u003eCC \u0026lt;0.2% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.1% of reading + 30 mV)\u003cbr\u003eCC ±(0.3% of reading + 5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit LED, voltage and current per channel (4 windows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature-controlled fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e319 × 146 × 226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=36\"\u003eUTP3305-II Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"181730080312X","offer_id":67601530028283,"sku":"181730080312X","price":262.0,"currency_code":"USD","in_stock":true},{"title":"181400100742X","offer_id":68312849055995,"sku":"181400100742X","price":262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTP3305-II-1.png?v=1790709334"},{"product_id":"mso5104hd-1-ghz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5104HD 1 GHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5104HD is a 1 GHz, 4-channel mixed signal oscilloscope built on UNI-T’s R12™ native 12-bit ADC architecture, with a 5 GSa\/s real-time sample rate (interleave mode), 500 Mpts standard memory depth, and a calculated rise time of ≤0.35 ns. The 12-bit resolution holds at the full 1 GHz bandwidth with no ERES averaging step or sample-rate trade-off, and Ultra Phosphor 3.0 acquisition delivers up to 800,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor full-bandwidth GaN\/SiC half-bridge and full-bridge characterization, four-channel power-converter validation at the highest switching frequencies, and small-lab consolidation across signal-integrity and power-electronics workloads, the MSO5104HD is the family flagship: 1 GHz of bandwidth headroom on the 50 Ω path (500 MHz on the 1 MΩ path), 75 µVrms background noise at full bandwidth, and the same nine-instrument workhorse platform that integrates spectrum analyzer, AWG, Bode plot, protocol analyzer, and power analysis into one bench instrument. Calculated rise time of ≤0.35 ns — matched to the 1 GHz analog front end — captures the fast edges of next-generation switching silicon without rounding.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 GHz Bandwidth, 4 Channels\u003c\/strong\u003e — 4-channel analog capture with 5 GSa\/s sample rate and 12-bit native vertical resolution, scaling to 16-bit with ERES.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Deep memory for extended captures without sample-rate trade-off; navigation and search across the full memory window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 wfms\/s Standard, 1.5 M in Sequential Mode\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display with 256 grayscale levels for rare-event hunting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical levels at full bandwidth, sixteen times the resolution of a conventional 8-bit oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Protocols Standard, Nine Optional\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, LIN included; CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 2.5 GHz Spectrum Analyzer\u003c\/strong\u003e — Enhanced FFT up to 4 Mpts, four traces and four detections, waterfall display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Built-in arbitrary waveform generator pairs with the optional Bode plot analyzer for closed-loop frequency-response measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Power Analysis Suite\u003c\/strong\u003e — Switching loss, harmonic analysis, SOA, R\u003csub\u003eDS(on)\u003c\/sub\u003e, modulation, slew rate, ripple analysis, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels with UT-M15\u003c\/strong\u003e — Add the UT-M15 logic probe pod for time-correlated mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements with Histogram and Trend\u003c\/strong\u003e — 27 measurements simultaneously displayed; 39-item single-channel parameter snapshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280×800 HD multi-touch with gesture support; full-SCPI WebServer for browser-based remote control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 1 GHz bandwidth and 5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to get there. ERES (enhanced resolution) extends effective vertical resolution up to 16-bit when bandwidth headroom is available, but the baseline 12-bit performance is the front-end’s native characteristic, not a software boost. For low-amplitude signal work — switching ripple riding on a busy DC rail, sensor-bridge outputs into a noisy ADC, jitter analysis on a clock line — the difference between 8-bit quantization steps showing through the measurement and 12-bit fidelity disappearing them is the difference between a usable capture and a noisy one. At 75 µVrms background noise on the full 1 GHz bandwidth, the 12-bit ADC reaches the front-end’s noise floor without quantization steps showing up in low-amplitude signal analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 800,000 wfms\/s, 1.5 M in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is up to 800,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window without missing them between screen redraws. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 400,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being an analysis-after-capture exercise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For small-lab consolidation and education-track lab benches, the integration replaces three to five separate instruments with one instrument footprint, one calibration chain, and one operator-training surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts\u003c\/h3\u003e\n\u003cp\u003e500 Mpts of acquisition memory standard, with adjustable depths from Auto (5 Mpts) through 25 kpts, 250 kpts, 500 kpts, 5 Mpts, 50 Mpts, 100 Mpts, and 500 Mpts. Deep memory matters when the acquisition window is long — minutes-long captures looking for an intermittent fault, multi-frame protocol traces across a power-on sequence, or extended ripple analysis across a load-step transient — because the sample rate stays at 5 GSa\/s for far longer than a shallow-memory scope before forcing a sample-rate trade-off. Combined with the navigation-and-search function (event, time, and marker navigation modes), the deep memory is searchable: zoom into a specific glitch in a 500 Mpt capture without scrolling through the rest.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Probe Pod (Optional)\u003c\/h3\u003e\n\u003cp\u003eMixed-signal capability is hardware-standard in the MSO5000HD chassis — the 16-digital-channel logic-analyzer front end is built in. Adding the digital channels requires the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit connections and connects directly to 8×2 square pins (2.54 mm) for fast attachment to development boards. Maximum digital sample rate is 1.25 GSa\/s with a minimum detectable pulse width of 800 ps, and threshold selection covers TTL, 5.0 V\/3.3 V\/2.5 V\/1.8 V CMOS, ECL, PECL, LVDS, and a custom level — covering essentially every common digital interface voltage on modern hardware. Digital and analog channels share the same time base, the same trigger system, and the same display, so a falling SPI clock edge and the analog-domain crosstalk it causes show up in the same frame.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Protocol Decoders — 6 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eSix protocols decode standard with the MSO5000HD: RS-232\/422\/485\/UART, I²C, SPI, CAN, and LIN. Nine additional protocols are available as separately licensed options: CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C. The decoder runs on dedicated decode hardware, not a software post-processing path, so decode results display in real time during acquisition rather than after-the-fact on saved data — the difference between “debug a protocol stack interactively” and “capture, save, transfer, open in a separate tool, decode.” Trigger-and-decode operates pause-and-record modes for both interactive bring-up and unattended logging, and the event list plus search function lets you jump to a specific framed event across a 500 Mpt capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD’s built-in spectrum analyzer leverages the 5 GSa\/s sample rate for a 0–2.5 GHz frequency range — useful for characterizing wideband signals, identifying spurious emissions, and verifying clock harmonics at frequencies beyond what 2.5 GSa\/s instruments can analyze. Enhanced FFT supports up to 4 Mpts with 4-channel parallel signal analysis, four traces and four detections, auto\/manual\/threshold marker types, marker point lists, and a waterfall-curve display mode for time-evolving spectra. For pre-compliance EMI screening, switching-supply noise hunting, and clock-quality verification, the integrated spectrum analyzer means one instrument covers both time-domain and frequency-domain measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional Multi-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds nine classes of power-electronics measurement to the MSO5000HD: power quality, surge current, safe operating area (SOA), harmonic analysis, R\u003csub\u003eDS(on)\u003c\/sub\u003e measurement, modulation analysis, switching-loss analysis, slew rate, and ripple analysis — with transient-response and power-efficiency measurements added in firmware updates. For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input. Connect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument — no post-processing workflow, no separate software tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time, useful for signal-integrity work where the parameter distribution matters as much as a single instantaneous value. The new top-and-bottom amplitude calculation strategy and the burst-region measurement function add capability for non-stationary signals where the measurement window has to be localized to a specific event rather than averaged across the full capture. Twenty-seven simultaneous on-screen parameters cover the full converter-cycle measurement set (vIN, vOUT, IL, vGS) without paging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTiming Analyzer — Bus Timing Conformance Testing\u003c\/h3\u003e\n\u003cp\u003eThe timing analyzer function performs conformance-grade timing measurements on serial bus signals: pulse width, amplitude, edge characteristics, setup time, and hold time on I²C, SPI, CAN, and I²S buses. For consumer-electronics manufacturing — mobile phones, smart wearables, home appliances, multimedia audio-video equipment, and automotive electronics — bus-timing consistency is the difference between a board that passes audit and one that fails customer qualification. The MSO5000HD generates exportable conformance test reports, turning the scope into a documentation tool for design verification and test-lab compliance work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive multi-touch display anchors the front-panel experience — touch, drag, pinch-to-zoom, and rectangle-drawing gestures for common waveform operations — while preserving the traditional knob-and-key controls that bench engineers want for fine adjustment. Mouse and keyboard are supported as additional input methods. For automation, the built-in WebServer provides browser-based instrument control over the network — SCPI commands, waveform export, and online user-manual access — from PC or mobile devices, and full SCPI compliance over LAN or USB Device enables programmatic control from LabVIEW, Python, or any SCPI-aware test framework. UNI-T’s free instrument manager runs on the PC side for graphical control without writing custom automation code.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Validation\u003c\/h3\u003e\n\u003cp\u003eFor high-speed digital design and signal-integrity validation, the MSO5104HD’s 1 GHz bandwidth, ≤0.35 ns rise time, and 75 µVrms full-bandwidth noise floor capture eye-diagram detail, jitter histograms, and protocol decode on PCIe Gen2 reference clocks, USB 3.0 high-speed lanes, and DDR4 timing windows — with 16 digital channels available via the UT-M15 logic probe pod.\u003c\/p\u003e\n\u003ch3\u003ePower Electronics Design and Validation\u003c\/h3\u003e\n\u003cp\u003eFor full-bandwidth wide-bandgap power-electronics validation, the MSO5104HD captures GaN and SiC gate-drive transitions, ringing, and overshoot at the rise-time edge of today’s switching silicon — with the optional power-analysis suite running switching-loss and harmonic measurement on the same instrument as the waveform capture.\u003c\/p\u003e\n\u003ch3\u003eTest Laboratory and Consultancy Work\u003c\/h3\u003e\n\u003cp\u003eFor test-lab work spanning customer-DUT compliance pre-screen and internal characterization, the MSO5104HD’s 1 GHz bandwidth, hardware-accelerated template testing, and built-in 2.5 GHz spectrum analyzer collapse three-instrument bench setups (scope + spectrum + AWG) into one footprint.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eProbe set: passive 10:1 voltage probes (4×) sized for the bandwidth of the analog front end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M15 Logic Probe Pod — adds 16 digital channels with high\/low 8-bit connectors and direct 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003eActive probes — for 50 Ω high-bandwidth signal-integrity work where a passive 10x probe limits visibility.\u003c\/li\u003e\n\u003cli\u003eCurrent probe(s) — for power-electronics work paired with the optional power-analysis suite; voltage and current probe simultaneously for switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003eAWG license — activates the dual-channel 50 MHz arbitrary waveform generator hardware in the chassis.\u003c\/li\u003e\n\u003cli\u003eBode plot license — pairs with the AWG for closed-loop frequency-response sweep on amplifiers, filters, and power-supply control loops.\u003c\/li\u003e\n\u003cli\u003ePower analysis license — activates the multi-class power-electronics measurement suite.\u003c\/li\u003e\n\u003cli\u003eProtocol decoder licenses — CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C, available individually.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/p\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/p\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/p\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/p\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the 50 Ω and 1 MΩ analog bandwidths on this 1 GHz model?\u003c\/p\u003e\n\u003cp\u003eOn the MSO5104HD, the 50 Ω coupling path delivers the full 1 GHz analog bandwidth, while the 1 MΩ coupling path tops out at 500 MHz. Use 50 Ω with active probes, RF-grade passive probes, and high-speed signal-integrity work where source impedance matters; use 1 MΩ with standard 10x passive probes for general-purpose lab measurement up to 500 MHz. The vertical scale and offset ranges differ between paths — check the “Vertical System” section of the detailed specifications below for the per-path breakdown.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO5000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup, or explore the broader UNI-T oscilloscope catalog.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.35 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=108\"\u003eMSO5104HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530126587,"sku":"181100300117X","price":5354.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/MSO5000HD-1.png?v=1790709335"},{"product_id":"utg1022x-pa-20-mhz-2ch-arbitrary-waveform-generator-with-4w-pa","title":"UTG1022X-PA 20 MHz 2Ch Arbitrary Waveform Generator with 4W PA","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTG1022X-PA\u003c\/strong\u003e is a 20 MHz dual-channel arbitrary waveform generator built around a 16-bit DAC and 200 MSa\/s sample rate, with a built-in 4 W power amplifier integrated into the chassis. The power amplifier output is a dedicated front-panel BNC that drives transducers, coils, audio loads, and other inputs directly — without the workspace impact, signal-chain complexity, or cost of a separate external power amplifier.\u003c\/p\u003e\n\u003cp\u003eGenerator specifications are identical to the standard UTG1022X: 7 modulation types (AM, FM, PM, ASK, FSK, PSK, PWM), linear and logarithmic sweep, three pulse-burst modes, 200 built-in arbitrary waveforms, a 7-digit frequency counter (100 mHz to 200 MHz), and USB-Device + USB-Host connectivity. The PA option is for engineers and educators who frequently drive low-impedance or current-hungry loads and want one instrument rather than two on the bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 4 W power amplifier\u003c\/strong\u003e — integrated into the chassis with dedicated front-panel BNC output. 1 µHz to 100 kHz frequency range, \u0026gt; 18 V\/µs slew rate (typical). Drives transducers, coils, and audio loads directly without an external amp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 MHz sine \/ 10 MHz square \u0026amp; pulse\u003c\/strong\u003e — dual-channel generator output with 1 µHz frequency resolution, 20 Vpp maximum amplitude (high-Z).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-bit vertical resolution\u003c\/strong\u003e — 65,536 amplitude levels. 4× the resolution of typical 14-bit Essential-tier generators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MSa\/s sample rate\u003c\/strong\u003e — 10 sample points per cycle at maximum sine frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 built-in arbitrary waveforms\u003c\/strong\u003e — comprehensive library; 4 kpts arbitrary waveform length for custom shapes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7 modulation types — AM, FM, PM, ASK, FSK, PSK, PWM\u003c\/strong\u003e — internal and external source.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse burst function\u003c\/strong\u003e — three modes (N-cycle, gated, infinite) with internal or external trigger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 7-bit frequency counter\u003c\/strong\u003e — 100 mHz to 200 MHz input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device and USB-Host\u003c\/strong\u003e — PC SCPI control plus direct thumb-drive arbitrary waveform upload.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTG1022X-PA Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In 4 W Power Amplifier\u003c\/h3\u003e\n\u003cp\u003eA 4 W power amplifier is integrated into the UTG1022X-PA chassis, with output on a dedicated front-panel BNC. Frequency range covers 1 µHz to 100 kHz, with typical slew rate \u0026gt; 18 V\/µs. The PA accepts the standard generator output internally and amplifies it for direct drive of low-impedance or current-hungry loads — piezoelectric transducers, small audio loads, magnetic coils, vibration drivers, and similar inputs where the standard 50 Ω generator output's current capacity is insufficient. For applications that previously required generator-plus-amplifier as a two-instrument signal chain, the UTG1022X-PA collapses the bench footprint to a single unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Power.png\" alt=\"UTG1022X-PA built-in 4W power amplifier output\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eA 4 W power amplifier is integrated into the UTG1022X-PA chassis, with output on a dedicated front-panel BNC. Frequency range covers 1 µHz to 100 kHz, with typical slew rate \u0026gt; 18 V\/µs. The PA accepts the standard generator output internally and amplifies it for direct drive of low-impedance or current-hungry loads — piezoelectric transducers, small audio loads, magnetic coils, vibration drivers, and similar inputs where the standard 50 Ω generator output's current capacity is insufficient. For applications that previously required generator-plus-amplifier as a two-instrument signal chain, the UTG1022X-PA collapses the bench footprint to a single unit.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Digital-Sampling.png\" alt=\"UTG1022X-PA 16-bit DAC sampling\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eA 16-bit DAC provides 65,536 amplitude levels — 4× the resolution of typical 14-bit Essential-tier generators. This reduces quantization-noise floor and produces measurably cleaner output, particularly on low-amplitude signals. The PA output inherits the DAC's resolution and frequency precision for clean amplified stimulus.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e16-Bit Vertical Resolution\u003c\/h3\u003e\n\u003cp\u003eA 16-bit DAC provides 65,536 amplitude levels — 4× the resolution of typical 14-bit Essential-tier generators. This reduces quantization-noise floor and produces measurably cleaner output, particularly on low-amplitude signals. The PA output inherits the DAC's resolution and frequency precision for clean amplified stimulus.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eDual-Channel Output with Same Function\u003c\/h3\u003e\n\u003cp\u003eBoth channels deliver the full feature set independently, in addition to the PA output. The full 20 Vpp output amplitude (high-Z) is maintained on both standard channels at 10 MHz. The PA output is sourced from one of the two channels (selectable), and the unused channel remains available for triggering, reference, or synchronized stimulus.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Dual.png\" alt=\"UTG1022X-PA dual-channel output capability\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBoth channels deliver the full feature set independently, in addition to the PA output. The full 20 Vpp output amplitude (high-Z) is maintained on both standard channels at 10 MHz. The PA output is sourced from one of the two channels (selectable), and the unused channel remains available for triggering, reference, or synchronized stimulus.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Modulations.png\" alt=\"UTG1022X-PA modulation menu showing 7 types\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eAM, FM, PM, ASK, FSK, PSK, and PWM with internal and external source. All modulation types are available on both standard channels and through the PA output (within the PA's 100 kHz bandwidth limit).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e7 Modulation Types\u003c\/h3\u003e\n\u003cp\u003eAM, FM, PM, ASK, FSK, PSK, and PWM with internal and external source. All modulation types are available on both standard channels and through the PA output (within the PA's 100 kHz bandwidth limit).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePulse Burst Function\u003c\/h3\u003e\n\u003cp\u003eThree burst modes: N-cycle (1 to 50,000 cycles per trigger), gated, and infinite. Trigger source configurable internal or external, with rising or falling edge selection. The PA output extends burst-mode pulse stimulus to higher-current loads — useful for solenoid testing, relay-coil characterization, and similar workflows where simple voltage-source pulse stimulus is insufficient.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Outputs-Bursts.png\" alt=\"UTG1022X-PA pulse burst output modes\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eThree burst modes: N-cycle (1 to 50,000 cycles per trigger), gated, and infinite. Trigger source configurable internal or external, with rising or falling edge selection. The PA output extends burst-mode pulse stimulus to higher-current loads — useful for solenoid testing, relay-coil characterization, and similar workflows where simple voltage-source pulse stimulus is insufficient.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Sweep-Function.png\" alt=\"UTG1022X-PA frequency sweep configuration\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLinear and logarithmic sweep across the full output range. Sweep time 1 ms to 500 s, ±0.1% accuracy. The PA output is particularly valuable for swept stimulus of resonance-prone loads — speaker testing, transducer characterization, and mechanical-resonance identification — where the higher current capability lets the load's actual behavior emerge rather than being masked by source-impedance limits.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFrequency Sweep\u003c\/h3\u003e\n\u003cp\u003eLinear and logarithmic sweep across the full output range. Sweep time 1 ms to 500 s, ±0.1% accuracy. The PA output is particularly valuable for swept stimulus of resonance-prone loads — speaker testing, transducer characterization, and mechanical-resonance identification — where the higher current capability lets the load's actual behavior emerge rather than being masked by source-impedance limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLow Jitter\u003c\/h3\u003e\n\u003cp\u003e150 ps typical pulse-wave jitter from the digital-sampling architecture. Timing precision carries through to amplified outputs, which matters when the load is sensitive to edge-placement accuracy — magnetic-pickup test, time-domain stimulus characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Jitter.png\" alt=\"UTG1022X-PA low-jitter output performance\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e150 ps typical pulse-wave jitter from the digital-sampling architecture. Timing precision carries through to amplified outputs, which matters when the load is sensitive to edge-placement accuracy — magnetic-pickup test, time-domain stimulus characterization.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Frequency-Range.png\" alt=\"UTG1022X-PA built-in frequency counter\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eA built-in frequency counter measures external signals from 100 mHz to 200 MHz (TTL compatible). Mounted on the shared front-panel FSK \/ CNT \/ Sync BNC, the counter activates when the sync output function is disabled.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e7-Bit Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA built-in frequency counter measures external signals from 100 mHz to 200 MHz (TTL compatible). Mounted on the shared front-panel FSK \/ CNT \/ Sync BNC, the counter activates when the sync output function is disabled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTransducer and Sensor Drive\u003c\/h3\u003e\n\u003cp\u003eFor piezoelectric transducer drive, magnetic-pickup excitation, and small-coil stimulus, the 4 W PA output delivers current the standard 50 Ω generator output cannot. Typical use: ultrasonic transducer characterization, geophone testing, accelerometer-stand drive, MR-fluid\/MR-damper stimulus.\u003c\/p\u003e\n\u003ch3\u003eAudio and Vibration Test\u003c\/h3\u003e\n\u003cp\u003eFor small loudspeaker characterization, vibration table drive, haptic-actuator testing, and audio-amplifier component verification, the built-in PA replaces an external Class-D or Class-AB amplifier in the signal chain. 100 kHz upper limit covers the full audible range plus ultrasonic.\u003c\/p\u003e\n\u003ch3\u003eEducation and Teaching Labs (Mechatronics, Acoustics)\u003c\/h3\u003e\n\u003cp\u003eFor curriculum involving real transducer or actuator stimulus — mechatronics labs, acoustics-class instruction, vibration-and-control instruction — the PA option removes the need for a separate amplifier instrument per station. One instrument per student, simpler hookup, lower per-station cost.\u003c\/p\u003e\n\u003ch3\u003eElectromechanical Test — Relays, Solenoids, Small Motors\u003c\/h3\u003e\n\u003cp\u003e4 W output at moderate-impedance loads drives small solenoids, latching relays, and miniature motors for stimulus testing. Combined with N-cycle and gated burst modes, the UTG1022X-PA replaces a generator-plus-amplifier-plus-pulse-driver chain with one instrument.\u003c\/p\u003e\n\u003ch3\u003eSMPS Control-Loop and Feedback-Path Characterization\u003c\/h3\u003e\n\u003cp\u003eFrequency-swept stimulus through the PA output characterizes feedback paths and control loops at the higher current levels that reveal nonlinear behavior. The 100 kHz upper limit covers the loop-crossover frequencies of most switching supplies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord conforming to destination country standard\u003c\/li\u003e\n\u003cli\u003eUSB cable (UT-D04)\u003c\/li\u003e\n\u003cli\u003eBNC-BNC cable (UT-L45)\u003c\/li\u003e\n\u003cli\u003eBNC-to-alligator clip cable (UT-L02A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cp\u003eThe UTG1000X Essential-Series consists of three SKUs sharing the same chassis, sample rate, modulation set, burst modes, and 16-bit DAC:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG1022X\u003c\/strong\u003e — 20 MHz sine \/ 10 MHz square (without PA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG1022X-PA\u003c\/strong\u003e — UTG1022X with built-in 4 W power amplifier (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG1042X\u003c\/strong\u003e — 40 MHz sine \/ 20 MHz square (without PA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up — UTG2000B Advanced-Series\u003c\/h3\u003e\n\u003cp\u003eFor deeper memory, higher sample rate, LAN connectivity, 10 MHz In\/Out reference, and a wider modulation envelope — without the built-in PA — the bench-form-factor \u003cstrong\u003eUTG2025A\u003c\/strong\u003e through \u003cstrong\u003eUTG2122B\u003c\/strong\u003e Advanced-Series generators cover 25 MHz to 120 MHz sine output. The external \u003cstrong\u003eUT-M14\u003c\/strong\u003e 10 W power amplifier option pairs with these for amplified-output scenarios at higher generator bandwidths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat loads can the 4 W PA drive directly?\u003c\/p\u003e\n\u003cp\u003e4 W into a typical 8 Ω resistive load works out to about 5.7 V RMS \/ 17 Vpk — suitable for small audio loads, miniature transducers, magnetic-pickup excitation, and small coil drive. For inductive or capacitive loads with significant reactive component, the \u0026gt; 18 V\/µs slew rate matters more than the wattage rating — check the load's impedance vs frequency to verify the PA can sustain the required current.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I use the PA output and the standard 50 Ω outputs simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes. The standard channels remain available for triggering, synchronization, or unrelated stimulus while the PA drives the load. The PA output is sourced from one of the two channels (selectable), and the unused channel is independent.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy pick the UTG1022X-PA over the UTG1022X plus a separate amplifier?\u003c\/p\u003e\n\u003cp\u003eThree reasons: bench footprint (one instrument vs two), cabling and signal-chain simplicity (no inter-instrument cable, no impedance-match tuning), and cost (the integrated PA is priced below the cost of a separate external amplifier of comparable rating). Trade-off: the PA bandwidth (100 kHz) and rated power (4 W) are fixed — a separate external amplifier can offer more headroom on either axis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the PA output have its own protection circuitry?\u003c\/p\u003e\n\u003cp\u003eYes. Standard short-circuit protection and overload protection apply to the PA output, the same as the standard generator outputs — an overload disables the output rather than damaging the instrument. Power up and check the output is enabled after clearing a fault condition.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the generator side of the UTG1022X-PA identical to the standard UTG1022X?\u003c\/p\u003e\n\u003cp\u003eYes. All standard generator specifications — frequency range, sample rate, DAC resolution, modulation types, burst modes, sweep, frequency counter, display, USB connectivity — match the standard UTG1022X. The PA option is additive; it does not change any base specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Power.png\" alt=\"UTG1022X-PA built-in 4W power amplifier output\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in 4 W power amplifier — 1 µHz to 100 kHz, \u0026gt; 18 V\/µs slew rate, dedicated front-panel BNC output\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Digital-Sampling.png\" alt=\"UTG1022X-PA 16-bit DAC sampling\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e16-bit DAC, 65,536 amplitude levels — resolution carries through to the PA output\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Dual.png\" alt=\"UTG1022X-PA dual-channel output capability\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTwo standard 50 Ω channels plus the PA output — three output paths on a single instrument\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Modulations.png\" alt=\"UTG1022X-PA modulation menu showing 7 types\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e7 modulation types across both standard channels and the PA output\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Outputs-Bursts.png\" alt=\"UTG1022X-PA pulse burst output modes\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eN-cycle, gated, and infinite burst — available on standard channels and PA output\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Sweep-Function.png\" alt=\"UTG1022X-PA frequency sweep configuration\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSwept stimulus through the 4 W PA output reveals load resonance behavior\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Jitter.png\" alt=\"UTG1022X-PA low-jitter output performance\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e150 ps typical pulse-wave jitter — timing precision through the PA output\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UTG1000X-Frequency-Range.png\" alt=\"UTG1022X-PA built-in frequency counter\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e7-bit frequency counter, 100 mHz to 200 MHz\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower amplifier output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 W (built-in), 1 µHz to 100 kHz, \u0026gt; 18 V\/µs slew rate (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax sine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MHz (standard generator output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax square \/ pulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax ramp frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax arbitrary wave frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 standard + 1 PA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 bits (65,536 amplitude levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary waveform length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in arbitrary waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200, non-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine, Square, Ramp, Pulse, Noise, DC, Arbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, PM, ASK, FSK, PSK, PWM (internal \u0026amp; external source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear, Logarithmic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms to 500 s, ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-cycle (1 to 50,000), Gated, Infinite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (50 Ω, standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mVpp to 10 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (high-Z, standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mVpp to 20 Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC offset range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 V (50 Ω) \/ ±10 V (high-Z)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput impedance (standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protected; overload disables waveform output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise \/ fall time (square, 1 Vpp, 50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 16 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse-wave jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ps typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ −125 dBc\/Hz (typical, 0 dBm, 10 kHz deviation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic distortion (THD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.2% (DC to 20 kHz, 1 Vpp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mHz to 200 MHz, 7-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch TFT LCD, WVGA 480 × 272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device, USB-Host, multi-function FSK \/ CNT \/ Sync BNC, PA output BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz; \u0026lt; 20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 × 103 × 316 mm \/ 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \/ storage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10°C to +40°C \/ −20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=23\"\u003eUTG1022X-PA Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601529995515,"sku":"181300100063X","price":358.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTG1022X-PA_Cables.jpg?v=1790709335"},{"product_id":"ut622a-lcr-meter","title":"UT622A LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622A is a professional-grade handheld LCR meter for component measurement in the field, on the bench, and in the classroom. It measures inductance, capacitance, resistance, impedance, ESR, and D\/Q at test frequencies of 100 Hz, 120 Hz, 1 kHz, and 10 kHz with 0.1% basic accuracy, using a 4-wire Kelvin connection for clean low-impedance readings.\u003c\/p\u003e\n\u003cp\u003eSelectable test signal levels, series\/parallel equivalent-circuit modelling, open\/short correction, and tolerance sorting make it a capable verification tool, and a rechargeable Li-polymer pack gives about 8 hours of portable use on a 2.8-inch color display.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003eTest frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with open\/short correction\u003c\/li\u003e\n\u003cli\u003eSeries and parallel equivalent-circuit modelling\u003c\/li\u003e\n\u003cli\u003eSelectable test signal: 0.1 \/ 0.3 \/ 1 Vrms\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622A Details\u003c\/h2\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch 320×240 TFT display, a rechargeable 1800 mAh Li-polymer pack good for about 8 hours, and a 420 g body make the UT622A practical to carry between bench, field, and lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e0.01 mΩ – 20 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eComponent verification and incoming inspection; field and bench troubleshooting of capacitors, inductors, and resistors; education and lab use; and small-batch sorting against tolerance bands.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat parameters does the UT622A measure?\u003c\/h3\u003e\n\u003cp\u003eInductance, capacitance, resistance, impedance, ESR, and dissipation\/quality factor (D\/Q), at 0.1% basic accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat test frequencies are available?\u003c\/h3\u003e\n\u003cp\u003e100 Hz, 120 Hz, 1 kHz, and 10 kHz.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eHow does it compare to the UT622C and UT622E?\u003c\/h3\u003e\n\u003cp\u003eThe UT622C adds a 100 kHz test frequency and Kelvin leads; the UT622E adds 100 kHz plus DC resistance (DCR) measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622A Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622A User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530192123,"sku":"180706280021X","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT622E_1_sq.jpg?v=1790709334"},{"product_id":"upo1204-200-mhz-4ch-digital-storage-oscilloscope","title":"UPO1204 200 MHz 4Ch Digital Storage Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UPO1204\u003c\/strong\u003e is a 200 MHz, four-channel digital storage oscilloscope with 2 GSa\/s real-time sample rate, 56 Mpts memory depth, and a 500,000 wfms\/s waveform capture rate (Fast Acquire mode). Ultra Phosphor 2.0 display technology drives 256-level intensity grading on a 7-inch WVGA TFT LCD, making it straightforward to distinguish frequent signal behavior from rare anomalies at a glance.\u003c\/p\u003e\n\u003cp\u003eFour channels, 56 Mpts of memory, an independent DVM module, an enhanced 1 Mpts FFT, and three serial bus protocols decoded as standard — features that typically migrate to mid-tier scopes. The UPO1204 keeps them on the value-tier bench, which is the value proposition for teaching labs running twenty stations and engineering teams sourcing a second scope without sacrificing capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 4 channels\u003c\/strong\u003e — 2 GSa\/s real-time sample rate (2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four), ≤ 1.8 ns calculated rise time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Mpts memory depth\u003c\/strong\u003e — capture full switching cycles and long protocol sequences without trading sample rate for record length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s waveform capture rate\u003c\/strong\u003e — Ultra Phosphor 2.0 with 256-level intensity grading, in Fast Acquire mode. Fast enough to surface intermittent events that slower scopes spend hours missing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Mpts enhanced FFT\u003c\/strong\u003e — frequency-domain analysis with frequency setting, demodulation mode, waterfall display, and marker measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent DVM module\u003c\/strong\u003e — dedicated AC\/DC True RMS digital voltmeter, operating in parallel with scope acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-digit hardware frequency counter\u003c\/strong\u003e — hardware-accelerated counter alongside the scope channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 serial bus decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI trigger and decode included; full-memory hardware decoding turns multi-second decode times into milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 automated measurements\u003c\/strong\u003e — time, voltage, frequency, and statistical measurements with cursor-area scoping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple trigger types\u003c\/strong\u003e — edge, pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb remote control\u003c\/strong\u003e — browser-based access from any PC or mobile device on the LAN; no driver software, no host application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI + LAN automation\u003c\/strong\u003e — Standard Command for Programmable Instruments over LAN for scripted test sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UPO1204 Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 2.0\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 2.0 is UNI-T's intensity-graded display technology. Waveforms paint with 256-level brightness, where signals that recur often appear bright and rare anomalies show as faint streaks against the baseline trace — the kind of detail a flat-color display paints over.\u003c\/p\u003e\n\u003cp\u003eStandard sampling reaches 150,000 wfms\/s; engaging Fast Acquire mode pushes the rate to 500,000 wfms\/s. Combined with hardware-accelerated continuous waveform recording at up to 120,000 frames, the scope catches glitches, runt pulses, and other transient events that 8-bit value-tier oscilloscopes typically don't surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_waveform_capture.png\" alt=\"UNI-T UPO1204 Ultra Phosphor 2.0 Waveform Capture\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1204 Ultra Phosphor 2.0 Waveform Capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_waveform_capture.png\" alt=\"UNI-T UPO1204 Ultra Phosphor 2.0 Waveform Capture\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1204 Ultra Phosphor 2.0 Waveform Capture\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eIndependent DVM Module\u003c\/h3\u003e\n\u003cp\u003eThe UPO1204 includes a built-in 4-bit digital voltmeter that operates in parallel with the scope channels, displaying AC\/DC True RMS values continuously while the oscilloscope captures waveforms. The DVM has its own display readout and a configurable warning when measurements exceed the specified range — a separate instrument's worth of capability without a separate instrument's bench space, useful for steady-state DC monitoring alongside dynamic AC measurement and for double-checking power-supply rails without breaking the trigger setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e1 Mpts Enhanced FFT\u003c\/h3\u003e\n\u003cp\u003eThe 1 Mpts FFT converts time-domain waveforms to the frequency domain at resolution that matches mid-tier oscilloscopes. Frequency setting, demodulation mode, waterfall display, and automatic peak marking are all standard, supporting EMI troubleshooting, switching-supply harmonic characterization, audio-band analysis, and clock-spur identification. Five window functions (Rectangle, Hanning, Blackman, Hamming, FlatTop) cover the common analysis trade-offs between frequency resolution and amplitude accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_fft.png\" alt=\"UNI-T UPO1204 1 Mpts Enhanced FFT View\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1204 1 Mpts Enhanced FFT View\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_fft.png\" alt=\"UNI-T UPO1204 1 Mpts Enhanced FFT View\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1204 1 Mpts Enhanced FFT View\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eStandard Bus Decoding — RS-232\/UART, I²C, SPI\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, and SPI trigger and decode are standard — no protocol licenses, no add-on packages. Decoded bus traffic overlays the waveform with field-level annotation, and the event list view shows decoded packets alongside the time stamps. Hardware decoding running across the full 56 Mpts memory turns what would be a tens-of-seconds software decode into a sub-second operation, making the UPO1000 a usable embedded-debug instrument rather than a strictly time-domain scope.\u003c\/p\u003e\n\u003cp\u003eNo optional protocol licenses are available on the UPO1204: CAN, CAN-FD, LIN, and FlexRay are not supported on this platform. Buyers who need automotive bus decoding should look at the UPO1000HD or MSO\/UPO2000 series, which support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e7-digit Hardware Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA 7-digit hardware-accelerated counter runs alongside the scope's standard automated measurements. The counter reads independently from the channel measurement engine, which gives stable, high-resolution frequency readings on stable signals without the jitter that software counters can exhibit on the lower-density end of the rate range. Useful for verifying oscillator frequencies, clock-recovery loops, and PWM duty cycles where a stable frequency number matters more than time-domain detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMultiple Trigger Types\u003c\/h3\u003e\n\u003cp\u003eBeyond standard edge triggering, the scope offers pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers. Runt and over-amplitude triggers isolate signal-integrity violations that an edge-only trigger would never catch; setup\/hold and Nth edge triggers isolate specific cycles in long protocol captures. The full set is standard, with no trigger-package upgrades to license.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e36 Automated Measurements with Cursor-Area Scoping\u003c\/h3\u003e\n\u003cp\u003eThirty-six automated measurement parameters cover time, voltage, frequency, and statistical categories: rise\/fall time, pulse width, duty cycle, frequency, period, amplitude, RMS, peak-peak, mean, standard deviation, and others. Each measurement supports cursor-area scoping — the measurement runs only within the cursor window rather than across the full record — useful for measuring a specific burst within a long capture without rezooming. Statistics (min, max, mean, std-dev) accumulate over time for characterization of measurement drift.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UPO1000_cursor_area.png\" alt=\"UNI-T UPO1204 Cursor-Area Measurement Mode\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1204 Cursor-Area Measurement Mode\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UPO1000_cursor_area.png\" alt=\"UNI-T UPO1204 Cursor-Area Measurement Mode\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1204 Cursor-Area Measurement Mode\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eWeb Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1204 to the LAN and access the full instrument from any web browser — PC, Mac, or mobile — with no driver installation, no host application, no setup. Capture screenshots, change settings, transfer waveform data, and run SCPI commands from any device on the network. Useful for shared lab instruments, rack-mounted teaching benches with cable runs across the room, and Python or LabVIEW automation scripts that drive the scope through standard SCPI over LAN.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eConnectivity (USB, LAN, AUX)\u003c\/h3\u003e\n\u003cp\u003eStandard interfaces include USB-Host (front and rear) for thumb-drive screenshot capture and firmware updates, USB-Device (rear) for SCPI over USB to a PC, Gigabit LAN for SCPI and web remote, and AUX output for triggered signal handoff. RS-232 is not present on this platform; SCPI runs over USB and LAN. The LAN connection supports both DHCP and static IP configuration for fixed-IP rack deployments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTeaching Lab and Trade-School Curriculum (Education)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-station deployment at value-tier prices: a real 4 channels scope on every bench, with the same Ultra Phosphor 2.0 UI that students will see in industry on the UPO1000HD and MSO1000HD families.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory and 1 Mpts FFT cover the full spectrum-and-time-domain undergraduate curriculum without the memory-vs-sample-rate trade-offs that entry scopes normally impose.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics let students focus on circuit behavior rather than measurement methodology, while the cursor-area mode supports manual measurement teaching.\u003c\/li\u003e\n\u003cli\u003eWeb-based remote control mirrors the screen for classroom demonstration without USB capture cables or projector adapters; SCPI over LAN supports Python and LabVIEW lab exercises.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eEmbedded Systems Development (R\u0026amp;D)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree serial bus decoders standard (RS-232\/UART, I²C, SPI) cover most low-speed embedded debug workflows without protocol-license fees.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory captures full firmware-boot and protocol sequences in a single trigger, with full-memory hardware decoding for sub-second decode of long captures.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module reads supply rails alongside scope traces — useful for verifying brownout, monitoring switching ripple, or validating reference-voltage stability during prototype bring-up.\u003c\/li\u003e\n\u003cli\u003eSCPI over LAN runs Python regression scripts on the same instrument that the bench engineer uses interactively — automation without a separate automation-class scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronics Service, Repair, and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench-portable form factor: AC-line bench scope sized for the typical service workshop without the depth or weight of a flagship instrument.\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 2.0 with 256-level intensity grading reveals signal-integrity violations (runt pulses, glitches) that flat-color displays paint over — the difference between fixing the root cause and replacing the symptom.\u003c\/li\u003e\n\u003cli\u003eHardware frequency counter gives stable rate readings for verifying oscillator and clock-recovery behavior during board-level repair.\u003c\/li\u003e\n\u003cli\u003eAC\/DC True RMS DVM module replaces the bench multimeter for steady-state checks while keeping the scope trigger configuration intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSwitching-Mode Power Supply Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth selection from 200 MHz matches the switching frequency range of low-frequency LLC and PFC stages through high-frequency GaN\/SiC designs, with 56 Mpts memory for capturing long startup transients without losing sample rate.\u003c\/li\u003e\n\u003cli\u003e1 Mpts FFT characterizes ripple harmonics and switching-noise spectral content for EMI pre-compliance investigation alongside time-domain switching analysis.\u003c\/li\u003e\n\u003cli\u003eMultiple trigger types (runt, over-amplitude, pulse-width) isolate switching faults, current spikes during startup, and protection-circuit activations.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module monitors output-rail DC value while scope captures dynamic AC load-step behavior — both halves of the supply characterization on one instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI over LAN supports rack-mounted production-line deployment with Python or LabVIEW test scripts; the web remote interface gives line operators a familiar browser-based view without driver installation on each test station.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics support go\/no-go testing of board-level signal-integrity specs; the cursor-area mode isolates specific cycles for measurement without re-zooming the full capture.\u003c\/li\u003e\n\u003cli\u003eContinuous waveform recording into the memory depth supports historical archiving of production-line captures for later analysis when a batch shows yield-tail issues.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eEMI Pre-Compliance Investigation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Mpts FFT with five window functions, demodulation mode, and waterfall display supports time-correlated EMI investigation against the time-domain switching waveform — useful for tracking down which switching event produces which emission peak.\u003c\/li\u003e\n\u003cli\u003eMarker measurement on the FFT supports quick peak frequency and amplitude readout during emission-hunt work on a prototype board.\u003c\/li\u003e\n\u003cli\u003eCombined with a near-field probe set and a Faraday-cage cardboard tent, the FFT view supports pre-compliance investigation that catches the obvious failures before the expensive compliance-lab booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1204 digital storage oscilloscope\u003c\/li\u003e\n\u003cli\u003ePower cord (national standard)\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 data cable\u003c\/li\u003e\n\u003cli\u003e4 × passive probes — UT-P07A (500 MHz, one per channel)\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-voltage passive probes\u003c\/strong\u003e — UT-P20 (100:1, 250 MHz), UT-V23 (100:1), UT-P21 (1000:1, DC 10 kV \/ AC 7 kVrms) for line-voltage and HV switching work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential probes\u003c\/strong\u003e — UT-P30, UT-P31, UT-P32, UT-P33, UT-P35, UT-P36 for floating measurements where ground reference can't be tied to scope chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent probes\u003c\/strong\u003e — UT-P40, UT-P41, UT-P42, UT-P43, UT-P44; UT-P4150 for high-current AC\/DC measurement on switching and motor-drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation transformer\u003c\/strong\u003e — UT-ISOT for line-powered DUTs that require galvanic isolation between scope ground and DUT ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO1054 — 50 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003e\nUPO1104 — 100 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPO1204\u003c\/strong\u003e — 200 MHz, 4 channels, 2 GSa\/s \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up — UPO1000HD (4-channel, 12-Bit Vertical)\u003c\/h3\u003e\n\u003cp\u003eIf your application needs higher vertical resolution or deeper memory than the UPO1204 provides, the UPO1000HD family offers 12-bit vertical resolution and the same Ultra Phosphor 2.0 display engine in the same cabinet footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO1084HD — 80 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003cli\u003e\nUPO1154HD — 150 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich serial bus protocols are decoded as standard, and which require a license?\u003c\/p\u003e\n\u003cp\u003eThe UPO1204 decodes \u003cstrong\u003eRS-232\/UART, I²C, and SPI\u003c\/strong\u003e as standard — trigger and decode functions for all three are included with the scope, with no license fees and no protocol-option purchase required. \u003cstrong\u003eNo optional protocol decoders are available on this platform.\u003c\/strong\u003e CAN, CAN-FD, LIN, and FlexRay are not supported on the UPO1000 platform. If your application requires automotive bus decoding, the UPO1000HD or MSO\/UPO2000 series support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is Fast Acquire mode, and when should I use it?\u003c\/p\u003e\n\u003cp\u003eFast Acquire is a UPO1000-series acquisition mode that boosts waveform capture rate from 150,000 wfms\/s (standard) to \u003cstrong\u003e500,000 wfms\/s\u003c\/strong\u003e. The trade-off is that some screen-update detail is sacrificed for raw capture throughput. Use Fast Acquire when hunting intermittent signal-integrity events (glitches, runt pulses, rare protocol violations) that depend on capturing many waveforms quickly. Use standard mode for everyday time-domain measurement work where the display refresh rate matters more than raw capture density.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the DVM module share input channels with the scope, or is it truly independent?\u003c\/p\u003e\n\u003cp\u003eThe DVM is \u003cstrong\u003etruly independent\u003c\/strong\u003e: it has its own 4-bit measurement input and operates in parallel with the four (or two) scope channels. You can run a continuous AC\/DC True RMS reading on a supply rail while the scope captures dynamic switching behavior on another channel, without any time-sharing between the two functions. The DVM readout appears on a dedicated portion of the screen and persists across scope-channel configuration changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does the web remote control look like in practice, and how does SCPI automation work?\u003c\/p\u003e\n\u003cp\u003eConnect the UPO1204 to your LAN, point any browser at the scope's IP, and you get a full-screen replica of the front panel that you can drive from your desk or a mobile device — no driver installation, no host application. Useful for shared lab instruments and projection during teaching demos. For automation, the scope responds to \u003cstrong\u003eSCPI commands over LAN\u003c\/strong\u003e (Standard Commands for Programmable Instruments), which means Python (pyvisa), MATLAB Instrument Control Toolbox, LabVIEW, and any other VISA-aware tool can drive the scope through scripts. SCPI also runs over USB-Device for PC-tethered automation when LAN isn't available.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate per Channel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.8 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Scale (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µV\/div to 20 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s (Fast Acquire mode); 150,000 wfms\/s normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Frame Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mpts enhanced FFT (5 window functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent module — 4-bit, AC\/DC True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 parameters with statistics and cursor-area scoping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup\/Hold, Nth Edge, Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Bus Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Protocol Decoders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone available on this platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch WVGA TFT LCD, 256-level intensity grading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (front + rear), USB-Device (rear), LAN (1 GbE), AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb browser (no driver), SCPI over LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e306 × 138 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=75\"\u003eUPO1204 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530257659,"sku":"181100200075X","price":553.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UPO1204_Probes.jpg?v=1790709335"},{"product_id":"ut-pa1000-1-ghz-active-single-ended-probe","title":"UT-PA1000 1 GHz Active Single-Ended Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e1 GHz active single-ended oscilloscope probe with ≤1.3 pF input capacitance and ±4V dynamic range. Designed for high-speed digital and RF signal integrity measurements on UNI-T MSO\/UPO oscilloscopes. Connects to UNI-T oscilloscopes and other oscilloscopes via BNC.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1GHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 1GHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±4 V Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530355963,"sku":"190500400006X","price":1365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-PA1000_1_sq.jpg?v=1790709334"},{"product_id":"mso5034hd-350-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5034HD 350 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5034HD is a 350 MHz, 4-channel mixed signal oscilloscope built on UNI-T’s R12™ native 12-bit ADC architecture, with a 5 GSa\/s real-time sample rate (interleave mode), 500 Mpts standard memory depth, and a calculated rise time of ≤1.00 ns. The 12-bit resolution holds at the full 350 MHz bandwidth with no ERES averaging step or sample-rate trade-off, and Ultra Phosphor 3.0 acquisition delivers up to 800,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping with high-resolution requirements, four-channel mixed-signal debug in dedicated R\u0026amp;D groups, and lab benches that need real 12-bit acquisition without stepping up to a 1 GHz instrument, the MSO5034HD is the family-entry door into the HD-scope tier above MSO3000HD — double the sample rate (5 GSa\/s vs 2.5 GSa\/s), the same 500 Mpts memory, and the same nine-instrument workhorse platform, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 MHz Bandwidth, 4 Channels\u003c\/strong\u003e — 4-channel analog capture with 5 GSa\/s sample rate and 12-bit native vertical resolution, scaling to 16-bit with ERES.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Deep memory for extended captures without sample-rate trade-off; navigation and search across the full memory window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 wfms\/s Standard, 1.5 M in Sequential Mode\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display with 256 grayscale levels for rare-event hunting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical levels at full bandwidth, sixteen times the resolution of a conventional 8-bit oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Protocols Standard, Nine Optional\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, LIN included; CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 2.5 GHz Spectrum Analyzer\u003c\/strong\u003e — Enhanced FFT up to 4 Mpts, four traces and four detections, waterfall display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Built-in arbitrary waveform generator pairs with the optional Bode plot analyzer for closed-loop frequency-response measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Power Analysis Suite\u003c\/strong\u003e — Switching loss, harmonic analysis, SOA, R\u003csub\u003eDS(on)\u003c\/sub\u003e, modulation, slew rate, ripple analysis, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels with UT-M15\u003c\/strong\u003e — Add the UT-M15 logic probe pod for time-correlated mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements with Histogram and Trend\u003c\/strong\u003e — 27 measurements simultaneously displayed; 39-item single-channel parameter snapshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280×800 HD multi-touch with gesture support; full-SCPI WebServer for browser-based remote control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 350 MHz bandwidth and 5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to get there. ERES (enhanced resolution) extends effective vertical resolution up to 16-bit when bandwidth headroom is available, but the baseline 12-bit performance is the front-end’s native characteristic, not a software boost. For low-amplitude signal work — switching ripple riding on a busy DC rail, sensor-bridge outputs into a noisy ADC, jitter analysis on a clock line — the difference between 8-bit quantization steps showing through the measurement and 12-bit fidelity disappearing them is the difference between a usable capture and a noisy one.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 800,000 wfms\/s, 1.5 M in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is up to 800,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window without missing them between screen redraws. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 400,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being an analysis-after-capture exercise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For small-lab consolidation and education-track lab benches, the integration replaces three to five separate instruments with one instrument footprint, one calibration chain, and one operator-training surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts\u003c\/h3\u003e\n\u003cp\u003e500 Mpts of acquisition memory standard, with adjustable depths from Auto (5 Mpts) through 25 kpts, 250 kpts, 500 kpts, 5 Mpts, 50 Mpts, 100 Mpts, and 500 Mpts. Deep memory matters when the acquisition window is long — minutes-long captures looking for an intermittent fault, multi-frame protocol traces across a power-on sequence, or extended ripple analysis across a load-step transient — because the sample rate stays at 5 GSa\/s for far longer than a shallow-memory scope before forcing a sample-rate trade-off. Combined with the navigation-and-search function (event, time, and marker navigation modes), the deep memory is searchable: zoom into a specific glitch in a 500 Mpt capture without scrolling through the rest.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Probe Pod (Optional)\u003c\/h3\u003e\n\u003cp\u003eMixed-signal capability is hardware-standard in the MSO5000HD chassis — the 16-digital-channel logic-analyzer front end is built in. Adding the digital channels requires the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit connections and connects directly to 8×2 square pins (2.54 mm) for fast attachment to development boards. Maximum digital sample rate is 1.25 GSa\/s with a minimum detectable pulse width of 800 ps, and threshold selection covers TTL, 5.0 V\/3.3 V\/2.5 V\/1.8 V CMOS, ECL, PECL, LVDS, and a custom level — covering essentially every common digital interface voltage on modern hardware. Digital and analog channels share the same time base, the same trigger system, and the same display, so a falling SPI clock edge and the analog-domain crosstalk it causes show up in the same frame.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Protocol Decoders — 6 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eSix protocols decode standard with the MSO5000HD: RS-232\/422\/485\/UART, I²C, SPI, CAN, and LIN. Nine additional protocols are available as separately licensed options: CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C. The decoder runs on dedicated decode hardware, not a software post-processing path, so decode results display in real time during acquisition rather than after-the-fact on saved data — the difference between “debug a protocol stack interactively” and “capture, save, transfer, open in a separate tool, decode.” Trigger-and-decode operates pause-and-record modes for both interactive bring-up and unattended logging, and the event list plus search function lets you jump to a specific framed event across a 500 Mpt capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD’s built-in spectrum analyzer leverages the 5 GSa\/s sample rate for a 0–2.5 GHz frequency range — useful for characterizing wideband signals, identifying spurious emissions, and verifying clock harmonics at frequencies beyond what 2.5 GSa\/s instruments can analyze. Enhanced FFT supports up to 4 Mpts with 4-channel parallel signal analysis, four traces and four detections, auto\/manual\/threshold marker types, marker point lists, and a waterfall-curve display mode for time-evolving spectra. For pre-compliance EMI screening, switching-supply noise hunting, and clock-quality verification, the integrated spectrum analyzer means one instrument covers both time-domain and frequency-domain measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional Multi-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds nine classes of power-electronics measurement to the MSO5000HD: power quality, surge current, safe operating area (SOA), harmonic analysis, R\u003csub\u003eDS(on)\u003c\/sub\u003e measurement, modulation analysis, switching-loss analysis, slew rate, and ripple analysis — with transient-response and power-efficiency measurements added in firmware updates. For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input. Connect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument — no post-processing workflow, no separate software tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time, useful for signal-integrity work where the parameter distribution matters as much as a single instantaneous value. The new top-and-bottom amplitude calculation strategy and the burst-region measurement function add capability for non-stationary signals where the measurement window has to be localized to a specific event rather than averaged across the full capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTiming Analyzer — Bus Timing Conformance Testing\u003c\/h3\u003e\n\u003cp\u003eThe timing analyzer function performs conformance-grade timing measurements on serial bus signals: pulse width, amplitude, edge characteristics, setup time, and hold time on I²C, SPI, CAN, and I²S buses. For consumer-electronics manufacturing — mobile phones, smart wearables, home appliances, multimedia audio-video equipment, and automotive electronics — bus-timing consistency is the difference between a board that passes audit and one that fails customer qualification. The MSO5000HD generates exportable conformance test reports, turning the scope into a documentation tool for design verification and test-lab compliance work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive multi-touch display anchors the front-panel experience — touch, drag, pinch-to-zoom, and rectangle-drawing gestures for common waveform operations — while preserving the traditional knob-and-key controls that bench engineers want for fine adjustment. Mouse and keyboard are supported as additional input methods. For automation, the built-in WebServer provides browser-based instrument control over the network — SCPI commands, waveform export, and online user-manual access — from PC or mobile devices, and full SCPI compliance over LAN or USB Device enables programmatic control from LabVIEW, Python, or any SCPI-aware test framework. UNI-T’s free instrument manager runs on the PC side for graphical control without writing custom automation code.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Validation\u003c\/h3\u003e\n\u003cp\u003eFor R\u0026amp;D validation on multi-rail digital boards, the MSO5034HD’s 12-bit native resolution at 350 MHz keeps low-amplitude signal artifacts — switching ripple, crosstalk, return-path noise — visible at scale during overnight regression captures, with 500 Mpts memory enabling deep zoom-and-search across long capture windows.\u003c\/p\u003e\n\u003ch3\u003ePower Electronics Design and Validation\u003c\/h3\u003e\n\u003cp\u003eFor power-electronics design at moderate switching frequencies, the MSO5034HD pairs four-channel acquisition with optional power-analysis software for switching-loss, efficiency, and ripple measurement on switch-mode and battery-management designs — same instrument, no separate power analyzer required.\u003c\/p\u003e\n\u003ch3\u003eTest Laboratory and Consultancy Work\u003c\/h3\u003e\n\u003cp\u003eFor internal test labs documenting compliance and pre-compliance characterization, the MSO5034HD’s 56 automated measurements with histogram and trend statistics, paired with hardware-accelerated template testing, generate the kind of pass\/fail evidence reports that internal-audit and external-customer test packages require.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eProbe set: passive 10:1 voltage probes (4×) sized for the bandwidth of the analog front end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M15 Logic Probe Pod — adds 16 digital channels with high\/low 8-bit connectors and direct 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003eActive probes — for 50 Ω high-bandwidth signal-integrity work where a passive 10x probe limits visibility.\u003c\/li\u003e\n\u003cli\u003eCurrent probe(s) — for power-electronics work paired with the optional power-analysis suite; voltage and current probe simultaneously for switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003eAWG license — activates the dual-channel 50 MHz arbitrary waveform generator hardware in the chassis.\u003c\/li\u003e\n\u003cli\u003eBode plot license — pairs with the AWG for closed-loop frequency-response sweep on amplifiers, filters, and power-supply control loops.\u003c\/li\u003e\n\u003cli\u003ePower analysis license — activates the multi-class power-electronics measurement suite.\u003c\/li\u003e\n\u003cli\u003eProtocol decoder licenses — CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C, available individually.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/p\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/p\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/p\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the AWG (arbitrary waveform generator) included or optional?\u003c\/p\u003e\n\u003cp\u003eThe AWG hardware is built into every MSO5000HD chassis as hardware-standard, but activation requires the AWG software license. Once activated, it provides dual-channel 50 MHz output with sine, square, pulse, ramp, arbitrary, noise, and DC waveforms; AM, FM, ASK, FSK, and sweep modulation; and the ability to load on-screen captured waveforms back to the Gen output for replay-style stimulus testing. The optional Bode plot analyzer pairs with the AWG for closed-loop frequency-response measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/p\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO5000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup, or explore the broader UNI-T oscilloscope catalog.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.00 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=108\"\u003eMSO5034HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BW3M5T1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BW5MT1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530454267,"sku":"181100300116X","price":3144.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/MSO5000HD-1_da02a954-f077-4234-8206-cd30abc1e345.png?v=1790709335"},{"product_id":"ut8804e-4-8-digit-advanced-series-bench-digital-multimeter","title":"UT8804E 4.8 Digit Advanced-Series Bench Digital Multimeter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UT8804E Advanced-Series Bench Digital Multimeter\u003c\/strong\u003e is a \u003cstrong\u003e4⅚-digit auto-ranging\u003c\/strong\u003e True-RMS meter with \u003cstrong\u003e0.025% basic DC voltage accuracy\u003c\/strong\u003e, a \u003cstrong\u003e59,999-count\u003c\/strong\u003e display, and a \u003cstrong\u003e4.3in TFT-LCD\u003c\/strong\u003e with digitized analog bar graph. Data recording, statistical analysis, trend-chart visualization, and Pass\/Fail batch comparison are built in.\u003c\/p\u003e\n\u003cp\u003eFor R\u0026amp;D bench validation, burn-in monitoring, and small-batch quality control where a basic 4½-digit meter lacks the recording-and-statistics workflow but a 6½-digit unit would be overkill, the UT8804E delivers measurement, logging, and analysis in one instrument. Thermocouple temperature measurement, multiple parameters per measurement function, and USB-Device PC connectivity are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4⅚-digit, 59,999-count display\u003c\/strong\u003e — 0.025% basic DC voltage accuracy at the tier price point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue-RMS AC measurement\u003c\/strong\u003e — accurate readings on non-sinusoidal waveforms (switching supplies, motor drives, PWM, dimmed loads).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-ranging\u003c\/strong\u003e — across voltage, current, resistance, and capacitance functions, reducing operator workflow friction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple temperature measurement\u003c\/strong\u003e — range -40°C to 1000°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData recording with statistics and trend-chart display\u003c\/strong\u003e — Pass\/Fail comparison for batch device testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device PC connection\u003c\/strong\u003e — included software for historical-data viewing and trend monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UT8804E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e4⅚-Digit Display and 0.025% Accuracy\u003c\/h3\u003e\n\u003cp\u003eThe UT8804E delivers a \u003cstrong\u003e4⅚-digit 59,999-count\u003c\/strong\u003e display with \u003cstrong\u003e0.025% basic DC voltage accuracy\u003c\/strong\u003e. DC voltage resolution is \u003cstrong\u003e0.001 mV\u003c\/strong\u003e and DC current resolution is \u003cstrong\u003e0.01μA\u003c\/strong\u003e — covering the precision needed for component validation, prototype bring-up, and general bench measurement. Resistance resolution is \u003cstrong\u003e0.01Ω\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Counts.png\" alt=\"59,999-count high-resolution 4⅚-digit display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e59,999-count high-resolution 4⅚-digit display\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Counts.png\" alt=\"59,999-count high-resolution 4⅚-digit display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e59,999-count high-resolution 4⅚-digit display\u003c\/span\u003e\n\n\u003ch3\u003eMeasurement Function Coverage\u003c\/h3\u003e\n\u003cp\u003eMeasurement coverage includes AC\/DC voltage, AC\/DC current, resistance, capacitance, diode, continuity, frequency, duty cycle, temperature (thermocouple). Capacitance measurement extends to \u003cstrong\u003e60 mF\u003c\/strong\u003e. Frequency counter range is \u003cstrong\u003e60 Hz – 60 MHz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTrue-RMS AC Measurement\u003c\/h3\u003e\n\u003cp\u003eTrue-RMS AC measurement delivers correct readings on distorted, non-sinusoidal waveforms — switching-mode power supply outputs, motor-drive currents, dimmed lighting loads, PWM signals — where an average-responding meter would read low. AC voltage and AC current measurements are both True-RMS.\u003c\/p\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Recording.png\" alt=\"Data recording with statistics and trend chart display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eData recording with statistics and trend chart display\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eData Recording and Trend Analysis\u003c\/h3\u003e\n\u003cp\u003eData recording captures historical measurements with real-time access to the current sample count, recording duration, extreme values, and averages. Recorded data renders as both statistical summary and trend chart; the cursor on the trend chart returns the value at a specific time point, useful for isolating anomalies in time-varying signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Recording.png\" alt=\"Data recording with statistics and trend chart display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eData recording with statistics and trend chart display\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMultiple Parameters per Measurement Function\u003c\/h3\u003e\n\u003cp\u003eFor each measurement function, the UT8804E exposes multiple parameter selections — for example, capacitance measurement can also display dissipation factor (D) or quality factor (Q) as a secondary parameter. The dual-parameter readout reduces function-key presses on multi-step measurement tasks and keeps both values visible during recording.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Multi.png\" alt=\"Multiple parameter selection within a single measurement function\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMultiple parameter selection within a single measurement function\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Multi.png\" alt=\"Multiple parameter selection within a single measurement function\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMultiple parameter selection within a single measurement function\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Pass.png\" alt=\"Pass\/Fail comparison function for batch device testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePass\/Fail comparison function for batch device testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePass\/Fail Comparison for Batch Testing\u003c\/h3\u003e\n\u003cp\u003ePass\/Fail comparison sets a tolerance window around an expected value; readings outside the window trigger an audible alarm and a visual indicator. For batch production-test work — incoming component inspection, finished-board QC, post-burn-in verification — Pass\/Fail flagging removes the operator-attention burden of reading the numeric display on every part.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Pass.png\" alt=\"Pass\/Fail comparison function for batch device testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePass\/Fail comparison function for batch device testing\u003c\/span\u003e\n\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMax \/ Min \/ Average Statistics with Timestamps\u003c\/h3\u003e\n\u003cp\u003eMaximum, minimum, and average value statistics track measurement extremes across a batch or time window. Each extreme reading is timestamped, so the trend chart cursor can return both the value and the moment it occurred — useful for isolating intermittent events in long-running tests.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Statistics.png\" alt=\"Maximum, minimum, and average statistics with timestamped extreme values\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMaximum, minimum, and average statistics with timestamped extreme values\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UT8804E-Statistics.png\" alt=\"Maximum, minimum, and average statistics with timestamped extreme values\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMaximum, minimum, and average statistics with timestamped extreme values\u003c\/span\u003e\n\n\u003ch3\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp\u003eThermocouple temperature measurement covers the range \u003cstrong\u003e-40°C to 1000°C\u003c\/strong\u003e with built-in cold-end compensation. Suitable for component-thermal-test, environmental monitoring, and process-temperature verification.\u003c\/p\u003e\n\u003ch3\u003eConnectivity and Remote Control\u003c\/h3\u003e\n\u003cp\u003eUSB-Device connection to a host PC enables real-time historical-data viewing, trend-chart display, and configuration backup through the included software. For workbench logging and remote monitoring of long-running tests where a separate data logger would be overkill, USB-Device provides the path.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Bench Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4⅚-digit measurement on prototype boards, switching-supply outputs, and sensor circuits.\u003c\/li\u003e\n\u003cli\u003eData recording during burn-in or temperature-cycle testing with trend-chart visualization.\u003c\/li\u003e\n\u003cli\u003eMaximum\/minimum statistics for capturing intermittent events during long-duration tests.\u003c\/li\u003e\n\u003cli\u003eComponent-thermal monitoring via thermocouple input.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmall-Batch Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePass\/Fail batch acceptance testing with audible alarm on out-of-spec readings.\u003c\/li\u003e\n\u003cli\u003eStatistical summary across a production batch (max, min, average, sample count).\u003c\/li\u003e\n\u003cli\u003eMulti-parameter validation within a single measurement function via secondary parameter readout.\u003c\/li\u003e\n\u003cli\u003eUSB-Device connection to a host PC for measurement logging and historical-data review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUniversity and Vocational Teaching Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMid-tier benchtop measurement instruction for second-year electronics and electrical engineering programs.\u003c\/li\u003e\n\u003cli\u003eMeasurement-fundamentals coursework covering recording, statistics, and trend visualization.\u003c\/li\u003e\n\u003cli\u003eCapstone project measurement with True-RMS AC and Pass\/Fail flagging.\u003c\/li\u003e\n\u003cli\u003eCost-effective stocking across multi-bench classroom installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUT8804E benchtop digital multimeter\u003c\/li\u003e\n\u003cli\u003eStandard test lead set\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eUSB-Device cable for PC connection\u003c\/li\u003e\n\u003cli\u003ePC software (included; downloadable from uni-trend.com)\u003c\/li\u003e\n\u003cli\u003eUser manual and factory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType-K thermocouple probe\u003c\/strong\u003e — for temperature measurement across the supported range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8802E\u003c\/strong\u003e — Value-tier 4½-digit manual-range bench DMM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8803E\u003c\/strong\u003e — Classic-tier 3⅚-digit auto-ranging bench DMM with inductance and D\/Q.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8804E\u003c\/strong\u003e — Advanced-tier 4⅚-digit bench DMM with data recording and Pass\/Fail. \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8805E\u003c\/strong\u003e — Performance-tier 5½-digit SCPI bench DMM with four-wire resistance and math.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806E\u003c\/strong\u003e — Performance-tier 6½-digit SCPI bench DMM (LAN\/RS-232\/USB).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT8806EG\u003c\/strong\u003e — Performance-tier 6½-digit bench DMM with IEEE-488.2 GPIB (substitutes for RS-232).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UT8804E compare to other models in the UT8800E series?\u003c\/p\u003e\n\u003cp\u003eThe UT8804E is the mid-tier Advanced model: 4⅚-digit precision with True-RMS, auto-ranging, a 4.3-inch TFT-LCD, data recording with trend-chart display, and Pass\/Fail batch comparison. It sits between the Classic UT8803E and the Performance-cohort UT8805E. If your work needs SCPI automation, fast reading rates, or four-wire resistance, step up to UT8805E or UT8806E.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I connect the UT8804E to a PC for data logging?\u003c\/p\u003e\n\u003cp\u003eYes. The USB-Device port connects the UT8804E to a host PC running the included software, which provides real-time historical-data viewing, trend-chart display, and configuration backup. The software is included free of charge; firmware updates over the product's lifetime are free.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UT8804E factory-calibrated, and how often does it need recalibration?\u003c\/p\u003e\n\u003cp\u003eYes — every UT8804E ships with a factory calibration certificate. The recommended recalibration interval is once per year for metrology-traceable measurement applications. For routine workbench use where the meter is being used for relative comparisons or go\/no-go checks against known references, longer intervals are acceptable. Recalibration is performed through Uni-Trend or an accredited third-party calibration laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat probes and accessories ship with the UT8804E?\u003c\/p\u003e\n\u003cp\u003eThe UT8804E ships with the standard probe and lead set appropriate to its measurement range, a power cord, the USB-Device cable for PC connection, the included software disc or download link, a user manual, and the factory calibration certificate. Verify the included contents against the packing list on delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Digits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4⅚ (4.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59,999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic DC Voltage Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.025%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Voltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Current Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Measurement Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Reading Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 rdgs\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrue-RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Range (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz – 60 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Frequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMath \/ Statistics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax\/Min\/Average, Pass\/Fail, Relative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20k\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3in TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=28\"\u003eUT8804E Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n  \u003cli\u003eUT8800 series safety instructions attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530519803,"sku":"180908080071X","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT8804E_Probes.jpg?v=1790709335"},{"product_id":"mso1154hd-150-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1154HD 150 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO1154HD is a 150 MHz, 4-channel, 12-bit Mixed Signal Oscilloscope built around UNI-T's native 12-bit ADC architecture (R12™). It samples at 2.5 GSa\/s with 100 Mpts of memory depth per channel and captures waveforms at up to 1,000,000 wfms\/s on a 7-inch capacitive touchscreen powered by Ultra Phosphor 3.0 acquisition technology.\u003c\/p\u003e\n\u003cp\u003eBuilt for embedded prototyping and curriculum-grade lab work, the 12-bit ADC delivers 4,096 vertical levels at the full 150 MHz bandwidth — the resolution gain that lets you see small ripple riding on a switching rail, or the subtle gain compression at the edge of an amplifier's linear range, without dropping into ERES averaging. Standard protocol decoding covers the full embedded-systems vocabulary (RS-232, UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio) at no additional cost. An optional 16-channel logic analyzer pod adds mixed-signal debugging when the project needs it.\u003c\/p\u003e\n\u003cp\u003eThe 9-in-1 architecture consolidates oscilloscope, logic analyzer (with optional UT-M26 pod), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer into one instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at 12-bit native resolution for mixed-signal debugging, switching-power analysis, and precision sensor work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/strong\u003e — 4,096 vertical levels at every supported bandwidth — no ERES averaging, no sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts\/Channel\u003c\/strong\u003e — Captures fast edges with sufficient timing resolution and holds long records without dropping sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000,000 wfms\/s Capture Rate\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display reveals rare anomalies and timing violations that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add mixed-signal debugging with the UT-M26 logic probe pod for time-correlated analog and digital views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Protocol Decoding Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding included at no additional cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e — FFT analysis up to 1 Mpts with peak detection and markers for harmonics, clock spurs, and EMI investigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Time, voltage, frequency, and power-quality parameters with statistical analysis and trend graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — 12 power-quality parameters including efficiency, ripple, and switching loss for switching-supply characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024×600 multi-gesture display with pinch-to-zoom, drag, and gesture navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Friendly Connectivity\u003c\/strong\u003e — USB Host\/Device, LAN, AUX Out, HDMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture. It samples at 4,096 quantization levels — sixteen times the vertical detail of a conventional 8-bit oscilloscope — and holds that resolution at the full 150 MHz bandwidth and 2.5 GSa\/s sample rate. There's no ERES averaging step, no sample-rate trade, and no asterisk on the spec sheet.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping at the value tier, R12 is what makes the MSO1154HD a credible benchtop scope rather than a hobby instrument with 12-bit on the spec sheet. On a workbench where the alternative is an 8-bit scope showing quantization steps over a switching-supply ripple measurement, the resolution gain is the difference between a debug session and an afternoon staring at a noisy trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 drives the acquisition system at up to 1,000,000 waveforms per second with 256 levels of color intensity mapping. The intensity-graded display shows you signal behavior patterns that a slower scope flattens into solid traces — rare glitches, edge jitter, and occasional protocol-layer anomalies appear as faint trace markings against the dominant signal.\u003c\/p\u003e\n\u003cp\u003eFor intermittent-fault investigation, this is the difference between catching the event in a two-minute capture and waiting for it across an overnight run. The probability of capturing rare anomalies scales with capture rate; one million waveforms per second puts you in the territory where most timing violations show up before lunch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory depth per channel maintains the full 2.5 GSa\/s sample rate across wide time-base settings — useful when teaching lab modules require capturing an extended sequence (a complete UART transaction, a startup transient, a slow PWM ramp) at sample-rate resolution. Zoom into any portion of the captured record at full resolution.\u003c\/p\u003e\n\u003cp\u003eFor embedded prototyping, deep memory means a single capture catches the slow events between fast edges — the millisecond-scale firmware delay that prevents an interrupt from firing on time, or the sequencing problem on a slow I²C bus. One acquisition replaces a multi-pass debug session.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eComprehensive protocol decoding included standard\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike higher-tier families that charge separately for automotive and industrial protocols, the MSO1000HD platform includes RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding standard at no additional cost. This makes it one of the most complete embedded-debug platforms in its segment, with no surprise license invoices when an automotive project crosses your bench.\u003c\/p\u003e\n\u003cp\u003eEach decoder correlates the physical-layer signal with the decoded data above the trace, so you can see signal-integrity anomalies and protocol errors in the same acquisition. Search and trigger on data patterns, error conditions, or specific bus events to isolate intermittent communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eComprehensive protocol decoding included standard\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eBuilt-In Power Analysis — 12 Parameters\u003c\/h3\u003e\n\u003cp\u003e12 standard power-quality parameters cover efficiency analysis, switching-loss measurement, safe-operating-area visualization, ripple-and-noise characterization, and harmonic content. The measurements run inline on the captured waveform — no scripting, no external software, no PC connection required.\u003c\/p\u003e\n\u003cp\u003eCombined with the 12-bit ADC and 100 Mpts memory, the power-analysis suite handles workloads that previously required a dedicated power analyzer. For switching-supply validation, gate-drive characterization, and small-signal-on-DC-rail measurements, the integrated functions consolidate a multi-instrument workflow into one bench unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 1 Mpts\u003c\/h3\u003e\n\u003cp\u003eFrequency-domain analysis with peak detection, markers, and waterfall display — up to 1 Mpts FFT length. Identify harmonics, clock spurs, switching-frequency content, and EMI contributions without switching to a separate spectrum analyzer or exporting waveform data to PC software.\u003c\/p\u003e\n\u003cp\u003eThe same trace that captured a glitch in the time domain immediately reveals its spectral character on the FFT — useful for chasing down EMI sources during pre-compliance work, or for distinguishing switching-supply harmonics from coupled noise on adjacent rails.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eMixed-Signal Debugging — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003e16 optional digital channels add mixed-signal debugging via the UT-M26 logic probe pod. The digital traces display alongside analog channels with full time correlation — see I²C bus traffic and analog ADC output on the same time axis, or watch a control firmware state machine drive the gate signals on a switching power stage.\u003c\/p\u003e\n\u003cp\u003eTime-correlated mixed-signal views are essential for debugging the boundary between firmware and analog hardware. A timing-violation that's invisible on either domain alone often becomes obvious when you can see the digital command and the analog response on the same trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurements cover time, voltage, frequency, and power-quality parameters with statistical analysis (min, max, mean, standard deviation) and trend graphs over long captures. For QA work and bench characterization, the statistical view is more useful than the instantaneous reading — it tells you whether a parameter is drifting, jittering, or holding steady.\u003c\/p\u003e\n\u003cp\u003ePass\/fail mask testing applies user-defined tolerance bands across captured waveforms — useful for rapid go\/no-go testing during bring-up, or for validating board-to-board consistency in small-volume production.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTouch UI and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch 1024×600 capacitive touchscreen supports pinch-to-zoom, drag, and gesture navigation across waveforms, menus, and measurement readouts. For students and lab newcomers, the touch interface lowers the barrier to advanced features that are buried behind menu trees on older instruments.\u003c\/p\u003e\n\u003cp\u003eConnectivity covers USB Host, USB Device, LAN, AUX Out, and HDMI. The HDMI output drives an external display for classroom demonstration, and LAN connectivity integrates the instrument into automated test scripts and remote-access workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Systems Prototyping\u003c\/strong\u003e — Mixed-signal debug for microcontroller boards, sensor interfaces, and low-power IoT designs. The 12-bit ADC reveals sensor-output detail that 8-bit scopes flatten into noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-Signal Debug\u003c\/strong\u003e — Time-correlated analog and digital views with the optional UT-M26 logic pod. Track firmware state machines against analog responses on the same trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Investigation\u003c\/strong\u003e — All standard embedded protocols included; no license fees for automotive (CAN, CAN-FD, LIN), industrial (RS-422\/485), or audio buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Spot Checks\u003c\/strong\u003e — FFT analysis identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEducation (Teaching Labs, Trade Schools, Community Colleges)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Station Teaching Labs\u003c\/strong\u003e — Twelve-bit resolution and full protocol coverage in a value-tier instrument lets you fit professional measurement capability into a curriculum-grade station budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTouchscreen UI Lowers Operator Barrier\u003c\/strong\u003e — Pinch-to-zoom and gesture navigation are familiar from consumer devices; students focus on the measurement, not the menu structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame Platform Across Course Levels\u003c\/strong\u003e — Beginning students use basic edge triggering; advanced students access protocol decode, FFT, and power-quality measurements on the same instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHDMI Output for Classroom Display\u003c\/strong\u003e — Drive an external monitor or projector for classroom demonstration of waveform examples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1154HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator? See the MSO1154HD-S for the same platform with a 25 MHz AWG and Bode plot analysis added. Need 250 MHz bandwidth for power-electronics work? See the MSO1254HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1154HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add digital channels for mixed-signal debugging?\u003c\/p\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes this model include a signal generator?\u003c\/p\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1154HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the MSO1154HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/p\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO1000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=111\"\u003eMSO1154HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300118X","offer_id":67601530552571,"sku":"181100300118X","price":691.0,"currency_code":"USD","in_stock":true},{"title":"181100300135X","offer_id":67601530585339,"sku":"181100300135X","price":691.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/MSO1154HD-1.png?v=1790709337"},{"product_id":"mso1254hd-250-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO1254HD 250 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO1254HD is a 250 MHz, 4-channel, 12-bit Mixed Signal Oscilloscope built around UNI-T's native 12-bit ADC architecture (R12™). It samples at 2.5 GSa\/s with 100 Mpts of memory depth per channel and captures waveforms at up to 1,000,000 wfms\/s on a 7-inch capacitive touchscreen powered by Ultra Phosphor 3.0 acquisition technology.\u003c\/p\u003e\n\u003cp\u003eBuilt for switching-supply validation, power-stage characterization, and faster-edge embedded debug, the 12-bit ADC delivers 4,096 vertical levels at the full 250 MHz bandwidth — the resolution that lets you measure mV-scale ripple on a 400 V rail, characterize gate-drive ringing on a GaN\/SiC half-bridge, and read efficiency curves with confidence in the small numbers. Standard protocol decoding covers the full embedded-systems vocabulary (RS-232, UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio) at no additional cost. An optional 16-channel logic analyzer pod adds mixed-signal correlation between control firmware and the analog power stage.\u003c\/p\u003e\n\u003cp\u003eThe 9-in-1 architecture consolidates oscilloscope, logic analyzer (with optional UT-M26 pod), spectrum analyzer, protocol analyzer, digital voltmeter, frequency counter, and power analyzer into one instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 MHz Bandwidth, 4 Analog Channels\u003c\/strong\u003e — Four-channel acquisition at 12-bit native resolution for mixed-signal debugging, switching-power analysis, and precision sensor work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/strong\u003e — 4,096 vertical levels at every supported bandwidth — no ERES averaging, no sample-rate trade.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s Sample Rate, 100 Mpts\/Channel\u003c\/strong\u003e — Captures fast edges with sufficient timing resolution and holds long records without dropping sample rate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1,000,000 wfms\/s Capture Rate\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display reveals rare anomalies and timing violations that slower scopes miss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Optional Digital Channels\u003c\/strong\u003e — Add mixed-signal debugging with the UT-M26 logic probe pod for time-correlated analog and digital views.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll Protocol Decoding Standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding included at no additional cost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e — FFT analysis up to 1 Mpts with peak detection and markers for harmonics, clock spurs, and EMI investigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements\u003c\/strong\u003e — Time, voltage, frequency, and power-quality parameters with statistical analysis and trend graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e — 12 power-quality parameters including efficiency, ripple, and switching loss for switching-supply characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1024×600 multi-gesture display with pinch-to-zoom, drag, and gesture navigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLab-Friendly Connectivity\u003c\/strong\u003e — USB Host\/Device, LAN, AUX Out, HDMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture. It samples at 4,096 quantization levels — sixteen times the vertical detail of a conventional 8-bit oscilloscope — and holds that resolution at the full 250 MHz bandwidth and 2.5 GSa\/s sample rate. There's no ERES averaging step, no sample-rate trade, and no asterisk on the spec sheet.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at full bandwidth, R12 is what lets the MSO1254HD characterize a GaN\/SiC half-bridge in the same bench session as the gate-drive ringing analysis. On a switching-node measurement where 8-bit quantization noise would obscure the µV-scale ripple riding on a 400 V rail, the 12-bit resolution recovers the signal that drives design decisions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_12-bit-screen.png\" alt=\"R12 12-bit ADC architecture at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative 12-bit ADC delivers 4,096 vertical levels at full bandwidth\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 drives the acquisition system at up to 1,000,000 waveforms per second with 256 levels of color intensity mapping. The intensity-graded display shows you signal behavior patterns that a slower scope flattens into solid traces — rare glitches, edge jitter, and occasional protocol-layer anomalies appear as faint trace markings against the dominant signal.\u003c\/p\u003e\n\u003cp\u003eFor intermittent-fault investigation, this is the difference between catching the event in a two-minute capture and waiting for it across an overnight run. The probability of capturing rare anomalies scales with capture rate; one million waveforms per second puts you in the territory where most timing violations show up before lunch.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Ultra-Phosphor-3.png\" alt=\"Ultra Phosphor 3.0 intensity-graded display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0 reveals rare events with intensity grading\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Per Channel\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory depth per channel maintains the full 2.5 GSa\/s sample rate across wide time-base settings — useful for capturing complete switching cycles in power-electronics validation, or recording an entire startup transient at full resolution. Zoom into any portion of the captured record at full resolution.\u003c\/p\u003e\n\u003cp\u003eFor switching-supply analysis, deep memory captures both the fast-edge transitions and the slow-recovery thermal events in a single acquisition. Soft-start sequences, fault-recovery behavior, and burst-mode operation become visible without piecing together multiple captures.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eComprehensive protocol decoding included standard\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eUnlike higher-tier families that charge separately for automotive and industrial protocols, the MSO1000HD platform includes RS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding standard at no additional cost. This makes it one of the most complete embedded-debug platforms in its segment, with no surprise license invoices when an automotive project crosses your bench.\u003c\/p\u003e\n\u003cp\u003eEach decoder correlates the physical-layer signal with the decoded data above the trace, so you can see signal-integrity anomalies and protocol errors in the same acquisition. Search and trigger on data patterns, error conditions, or specific bus events to isolate intermittent communication faults.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Protocols.png\" alt=\"Comprehensive protocol decoding included as standard\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eComprehensive protocol decoding included standard\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eBuilt-In Power Analysis — 12 Parameters\u003c\/h3\u003e\n\u003cp\u003e12 standard power-quality parameters cover efficiency analysis, switching-loss measurement, safe-operating-area visualization, ripple-and-noise characterization, and harmonic content. The measurements run inline on the captured waveform — no scripting, no external software, no PC connection required.\u003c\/p\u003e\n\u003cp\u003eCombined with the 12-bit ADC and 100 Mpts memory, the power-analysis suite handles workloads that previously required a dedicated power analyzer. For switching-supply validation, gate-drive characterization, and small-signal-on-DC-rail measurements, the integrated functions consolidate a multi-instrument workflow into one bench unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 1 Mpts\u003c\/h3\u003e\n\u003cp\u003eFrequency-domain analysis with peak detection, markers, and waterfall display — up to 1 Mpts FFT length. Identify harmonics, clock spurs, switching-frequency content, and EMI contributions without switching to a separate spectrum analyzer or exporting waveform data to PC software.\u003c\/p\u003e\n\u003cp\u003eThe same trace that captured a glitch in the time domain immediately reveals its spectral character on the FFT — useful for chasing down EMI sources during pre-compliance work, or for distinguishing switching-supply harmonics from coupled noise on adjacent rails.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO1000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer up to 1 Mpts\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in FFT spectrum analyzer for harmonics and EMI investigation\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eMixed-Signal Debugging — 16 Optional Digital Channels\u003c\/h3\u003e\n\u003cp\u003e16 optional digital channels add mixed-signal debugging via the UT-M26 logic probe pod. The digital traces display alongside analog channels with full time correlation — see I²C bus traffic and analog ADC output on the same time axis, or watch a control firmware state machine drive the gate signals on a switching power stage.\u003c\/p\u003e\n\u003cp\u003eTime-correlated mixed-signal views are essential for debugging the boundary between firmware and analog hardware. A timing-violation that's invisible on either domain alone often becomes obvious when you can see the digital command and the analog response on the same trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurements cover time, voltage, frequency, and power-quality parameters with statistical analysis (min, max, mean, standard deviation) and trend graphs over long captures. For QA work and bench characterization, the statistical view is more useful than the instantaneous reading — it tells you whether a parameter is drifting, jittering, or holding steady.\u003c\/p\u003e\n\u003cp\u003ePass\/fail mask testing applies user-defined tolerance bands across captured waveforms — useful for rapid go\/no-go testing during bring-up, or for validating board-to-board consistency in small-volume production.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTouch UI and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 7-inch 1024×600 capacitive touchscreen supports pinch-to-zoom, drag, and gesture navigation across waveforms, menus, and measurement readouts. For students and lab newcomers, the touch interface lowers the barrier to advanced features that are buried behind menu trees on older instruments.\u003c\/p\u003e\n\u003cp\u003eConnectivity covers USB Host, USB Device, LAN, AUX Out, and HDMI. The HDMI output drives an external display for classroom demonstration, and LAN connectivity integrates the instrument into automated test scripts and remote-access workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Supply Validation\u003c\/strong\u003e — Capture switching transitions and measure mV-scale ripple on multi-hundred-volt rails. The 12-bit ADC at full 250 MHz bandwidth resolves the small-signal-on-large-DC measurements that drive design decisions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed-Signal Debug\u003c\/strong\u003e — Time-correlated analog and digital views with the optional UT-M26 logic pod. Track firmware state machines against analog responses on the same trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Investigation\u003c\/strong\u003e — All standard embedded protocols included; no license fees for automotive (CAN, CAN-FD, LIN), industrial (RS-422\/485), or audio buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity Spot Checks\u003c\/strong\u003e — FFT analysis identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching-Loss Characterization\u003c\/strong\u003e — Built-in power-analysis measurements run inline on the captured waveform — no scripting, no external software. Quantify gate-drive losses, conduction losses, and switching transient energy in one capture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft-Start and Fault-Recovery Capture\u003c\/strong\u003e — 100 Mpts deep memory records the entire transient at sample-rate resolution; no piecing together multi-pass captures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple and Noise on DC Rails\u003c\/strong\u003e — The 12-bit ADC resolves µV-scale ripple on multi-hundred-volt DC rails — measurements that an 8-bit scope fundamentally cannot make.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic Content Investigation\u003c\/strong\u003e — Built-in FFT to 1 Mpts identifies switching-frequency content, harmonics, and coupled noise sources.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMSO1254HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M26 — 16-channel logic probe pod for mixed-signal debugging\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed an integrated signal generator and Bode plot analysis? See the MSO1254HD-S. Need a 150 MHz value-tier option? See the MSO1154HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO1254HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, and Audio decoding are included standard at no additional cost. All supported protocols are available out of the box — no optional licenses required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add digital channels for mixed-signal debugging?\u003c\/p\u003e\n\u003cp\u003eYes. The UT-M26 logic probe pod adds 16 digital channels for time-correlated analog and digital views.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes this model include a signal generator?\u003c\/p\u003e\n\u003cp\u003eNo. For an integrated 1-channel 25 MHz AWG with Bode plot analysis, see the MSO1254HD-S.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the MSO1254HD compare to the higher-bandwidth UPO2000HD or MSO3000HD scopes?\u003c\/p\u003e\n\u003cp\u003eThe MSO1000HD platform shares the same R12™ 12-bit ADC architecture, Ultra Phosphor 3.0 acquisition, and standard-included protocol decoding as the UPO2000HD and MSO3000HD families. The differences are bandwidth (150–250 MHz here vs 100–500 MHz on UPO2000HD and 350–1000 MHz on MSO3000HD), capture rate (1,000,000 wfms\/s here vs 1,500,000 wfms\/s on MSO3000HD), and the front-panel form factor. For embedded prototyping and mid-tier power-electronics work, the MSO1000HD platform delivers the same architectural advantages at a lower price point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO1000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Optional Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch capacitive touchscreen, 1024×600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, runt, slope, zone, setup\/hold, and more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, RS-422, RS-485, CAN, CAN-FD, LIN, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 1 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (available on -S models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional 16-channel via UT-M26 pod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=111\"\u003eMSO1254HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"181100300120X","offer_id":67601530618107,"sku":"181100300120X","price":809.0,"currency_code":"USD","in_stock":true},{"title":"181100300133X","offer_id":67601530650875,"sku":"181100300133X","price":809.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/MSO1254HD-S_and_MSO1254HD-1.png?v=1790709337"},{"product_id":"ut622c-100-khz-lcr-meter","title":"UT622C 100 kHz LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622C is a professional-grade handheld LCR meter that extends component testing to 100 kHz. Across 100 Hz, 120 Hz, 1 kHz, 10 kHz, and 100 kHz it measures L, C, R, impedance, ESR, and D\/Q at 0.1% basic accuracy, with a 4-wire Kelvin connection and included Kelvin test leads for repeatable low-impedance readings.\u003c\/p\u003e\n\u003cp\u003eThe higher 100 kHz frequency characterizes parts closer to their working conditions — useful for production QC and design verification — with series\/parallel modelling, open\/short correction, and tolerance sorting on a portable Li-polymer-powered instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest frequencies to 100 kHz: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/li\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with included Kelvin test leads\u003c\/li\u003e\n\u003cli\u003eOpen\/short correction; series and parallel modelling\u003c\/li\u003e\n\u003cli\u003eSelectable test signal: 0.1 \/ 0.3 \/ 1 Vrms\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622C Details\u003c\/h2\u003e\n\u003ch3\u003eTesting to 100 kHz\u003c\/h3\u003e\n\u003cp\u003eExtending the top test frequency to 100 kHz lets you characterize capacitors and inductors closer to the frequencies they operate at, where parameters like ESR and impedance differ meaningfully from their low-frequency values — important for production QC and design verification.\u003c\/p\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch color display, included Kelvin test leads, and a rechargeable Li-polymer pack good for about 8 hours make the UT622C ready for bench and line use.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e—\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mΩ – 20 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eProduction QC and incoming inspection; design verification of capacitors and inductors at higher frequency; component characterization on the bench; and tolerance sorting in small-batch manufacturing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat does the 100 kHz frequency add?\u003c\/h3\u003e\n\u003cp\u003eIt characterizes components closer to their operating frequency, where ESR and impedance can differ from low-frequency values.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eDoes it include Kelvin leads?\u003c\/h3\u003e\n\u003cp\u003eYes — Kelvin test leads are included for repeatable 4-wire low-impedance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eHow is it different from the UT622E?\u003c\/h3\u003e\n\u003cp\u003eThe UT622E adds DC resistance (DCR) measurement from 0.01 mΩ to 20 MΩ on top of the same 100 kHz LCR capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622C Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622C User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530683643,"sku":"180706280022X","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT622E_1_sq_2521fa9e-9679-499d-9815-514f2f61a781.jpg?v=1790709337"},{"product_id":"utl1020s-200w-high-resolution-programmable-dc-electronic-load","title":"UTL1020S 200W High-Resolution Programmable DC Electronic Load","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTL1020S\u003c\/strong\u003e is a single-channel programmable DC electronic load rated 200 W, 0–150 V, 0–30 A. It runs four constant modes — CC, CV, CR, CP — plus eleven additional test modes including dynamic, OVP, OCP, time, CR-LED, battery, automatic list, short-circuit, load-effect, combination, and list, for 15 test modes in total. Synchronous sampling reaches 500 kHz with high-performance DSP processing and a self-adaptive voltage and current waveform display on the 4.3-inch TFT LCD.\u003c\/p\u003e\n\u003cp\u003eDynamic mode pulls load at up to 50 kHz so current and voltage peaks — Vpp and Ipp — can be observed directly. The load also provides on-screen ripple measurement, a rear-panel Sense terminal for remote voltage compensation, and SCPI remote control over RS232 with a HANDLER interface and USB Host port for data logging and automated production test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — 200 W 15-Mode Load\u003c\/h2\u003e\n\u003cp\u003eTwo 200 W models share the same load architecture, the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. They differ in one axis only: measurement resolution.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e (high-resolution)\u003c\/td\u003e\n\u003ctd\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV — finer metering for precision readback work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e (standard resolution)\u003c\/td\u003e\n\u003ctd\u003eSame 200 W load, same 15 modes; current resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV. The lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThis page describes the \u003cstrong\u003eUTL1020S\u003c\/strong\u003e. Capability, test modes, protection, and interfaces below apply to both 200 W models; the Specifications table lists this model's resolution figures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 W, 0–150 V, 0–30 A single-channel load\u003c\/strong\u003e — CC, CV, CR, CP basic modes with dual high\/low input ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 test modes\u003c\/strong\u003e — CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 kHz synchronous sampling\u003c\/strong\u003e — high sampling density for accurate transient capture and reduced measurement omission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 kHz dynamic mode\u003c\/strong\u003e — programmable rise\/fall slope (0.0006–3 A\/µs) simulates real changing load conditions; Vpp \/ Ipp observed directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery test with charge and discharge curves\u003c\/strong\u003e — records both charge and discharge curves for battery characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic list test\u003c\/strong\u003e — up to 200-step programmable multi-mode sequences for automated, repeatable testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-screen ripple measurement and real-time waveform\u003c\/strong\u003e — ripple readout in the screen corner; [WAVE] key shows live V\/I waveform without an external oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote compensation (Sense terminal)\u003c\/strong\u003e — rear-panel Sense terminal eliminates lead voltage-drop error at high current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS232 \/ USB Host \/ HANDLER, SCPI protocol\u003c\/strong\u003e — PC software control, USB-drive screenshots and list import\/export, HANDLER for ATE integration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV, 16-bit CR, 3 years standard + 2 year extension.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTL1020S Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/h3\u003e\n\u003cp\u003eFour constant modes — CC (constant current), CV (constant voltage), CR (constant resistance), CP (constant power) — plus eleven more: dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short-circuit, load effect, combination, and list. The CR-LED mode simulates real LED forward-voltage behavior for LED-driver testing; battery mode records charge and discharge curves; combination mode pairs two basic modes (CR+CC, CV+CR, CV+CC) for more realistic DUT conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S 15 test modes covering power, battery, and LED-driver validation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S dynamic mode 50 kHz transient load simulation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/h3\u003e\n\u003cp\u003eDynamic mode pulls load at frequencies up to 50 kHz with T1\/T2 timing from 10 µs to 50 s (1 µs resolution) and a programmable rising\/falling current slope of 0.0006 A\/µs to 3 A\/µs. The current and voltage peak waveforms are observed directly on screen with Vpp and Ipp measurement, so transient response and overshoot of the device under test can be characterized without a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBattery Test with Charge and Discharge Curves\u003c\/h3\u003e\n\u003cp\u003eBattery mode performs constant-current or constant-power discharge testing and records the full discharge curve. The UTL1020S captures both the discharge and the charging curve, so capacity, internal-resistance behavior, and cycle characteristics are traceable from a single instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S battery test recording charge and discharge curves\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S automatic list test with up to 200 programmable steps\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/h3\u003e\n\u003cp\u003eThe automatic list test runs editable multi-step, multi-mode sequences with up to 200 steps. Set the appropriate load value and mode for each step and the list executes the full test process automatically. List files save to internal memory or a USB drive and can be imported, so a validated production-test sequence transfers between units quickly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/h3\u003e\n\u003cp\u003eRipple is measured and displayed directly in the corner of the screen, replacing a separate oscilloscope measurement for routine power-supply ripple checks. Pressing the [WAVE] function key shows the live voltage and current waveform, with the self-adaptive display scaling automatically to the signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S on-screen ripple measurement and real-time waveform display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S OVP and OCP protection-function testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOVP and OCP Protection Testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eOVP and OCP Protection Testing\u003c\/h3\u003e\n\u003cp\u003eSet the protection threshold according to the device under test and the UTL1020S measures the protection function and the protection response time. Overvoltage protection triggers with delayed protection at ≥ 152 V and immediate protection at ≥ 165 V; overcurrent protection at ≥ 30.3 A delayed and ≥ 33 A immediate; overpower at ≥ 202 W delayed and ≥ 220 W immediate. Instrument protection can also be turned off to prevent false alarms during characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLoad Effect Test\u003c\/h3\u003e\n\u003cp\u003eThe load effect test automatically measures and calculates load-regulation results from the configured test values, so power-supply load regulation is characterized without manual point-by-point measurement and calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S automated load effect \/ load regulation test\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLoad Effect Test\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S time test measuring power-supply rise and fall time\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/h3\u003e\n\u003cp\u003eTime test measures the rise and fall times of the device under test against configured thresholds, with 1 µs timing resolution and ±100 ppm timing accuracy, for power-supply turn-on \/ turn-off and transient-timing characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe 200 W 15-mode envelope — CC\/CV\/CR\/CP plus dynamic, battery, list, protection, load-effect, and combination modes with 500 kHz sampling — covers R\u0026amp;D and production test for power electronics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching power-supply and adapter test\u003c\/strong\u003e — load regulation, ripple, transient response, and protection-function verification from one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery and battery-pack characterization\u003c\/strong\u003e — charge and discharge curve recording for capacity, BMS, and cycle testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED-driver validation\u003c\/strong\u003e — CR-LED mode simulates real LED forward-voltage behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger and power-bank testing\u003c\/strong\u003e — automatic list sequences for repeatable multi-step production test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-DC converter and module test\u003c\/strong\u003e — dynamic loading at up to 50 kHz to characterize transient overshoot and recovery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated production test (ATE)\u003c\/strong\u003e — SCPI over RS232 plus HANDLER interface for test-line integration; list import\/export for fast line setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eRS232 communication cable\u003c\/li\u003e\n\u003cli\u003ePlug-in terminal block (5.08-2P) and screw-free spring terminal block (2.54-6P)\u003c\/li\u003e\n\u003cli\u003eSpare fuse (2 pcs)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and multi-language safety precautions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Test Leads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0615-OO\u003c\/strong\u003e — double O-type terminal, 60 A \/ 1.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0320-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0312-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 1.2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BB\u003c\/strong\u003e — double fold-insert, 10 A \/ 1 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BU\u003c\/strong\u003e — fold-insert to U-type, 10 A \/ 1 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUTL1000S Series\u003c\/h3\u003e\n\u003cp\u003eFour models share the same chassis, 15 test modes, 500 kHz sampling, accuracy class, and 0–150 V \/ 0–30 A input envelope:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e — 200 W, high-resolution (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e — 200 W, standard resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S\u003c\/strong\u003e — 400 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S-E\u003c\/strong\u003e — 400 W, standard resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the UTL1020S and the UTL1020S-E?\u003c\/p\u003e\n\u003cp\u003eBoth are 200 W loads with the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. The difference is measurement resolution: the UTL1020S resolves current to 0.01 mA \/ 0.1 mA and voltage readback to 0.01 mV \/ 0.1 mV across its low and high ranges. The high-resolution model is suited to precision readback work; the standard-resolution model is the lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow many test modes does the UTL1020S have, and what are they?\u003c\/p\u003e\n\u003cp\u003e15 modes: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list. The four constant modes (CC, CV, CR, CP) cover standard load testing; the remaining modes add transient, protection, battery, LED-driver, automated, and combination testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UTL1020S test batteries?\u003c\/p\u003e\n\u003cp\u003eYes. Battery mode performs discharge testing and records both the discharge and the charging curve, so capacity and cycle behavior are traceable from the instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes it measure ripple without an oscilloscope?\u003c\/p\u003e\n\u003cp\u003eYes. Ripple is measured and displayed in the corner of the screen, and the [WAVE] key shows the live voltage and current waveform, so routine ripple and waveform checks do not require a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the Sense terminal for?\u003c\/p\u003e\n\u003cp\u003eAt high current, lead resistance creates a voltage drop between the load and the device under test. The rear-panel Sense terminal measures voltage at the DUT output terminal directly (remote compensation), so the displayed voltage reflects the DUT rather than the voltage after the test leads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow is the UTL1020S controlled remotely?\u003c\/p\u003e\n\u003cp\u003eOver RS232 using the standard SCPI protocol with the included PC data-acquisition software. A HANDLER interface supports automated test-line integration, and a USB Host port accepts a USB drive for screenshots and for importing or exporting list files.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S 15 test modes covering power, battery, and LED-driver validation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S dynamic mode 50 kHz transient load simulation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S battery test recording charge and discharge curves\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S automatic list test with up to 200 programmable steps\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S on-screen ripple measurement and real-time waveform display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S OVP and OCP protection-function testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOVP and OCP Protection Testing\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S automated load effect \/ load regulation test\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLoad Effect Test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S time test measuring power-supply rise and fall time\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–15 V (low) \/ 0–150 V (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3 A (low) \/ 0–30 A (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 V ± 0.1 V at 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCV mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.1–150 V, resolution 1 mV, accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCC mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution 0.01 mA \/ 0.1 mA (low \/ high), accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCR mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.05 Ω – 10 kΩ, resolution 16 bits, accuracy (0.1 + 0.01R)%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCP mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 200 W, resolution 10 mW, accuracy ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CC\/CP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mV \/ 0.1 mV (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CV\/CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback current resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 mA \/ 0.1 mA (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback accuracy (V \/ I \/ P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.02% + 0.3% FS) \/ ±(0.03% + 0.05% FS) \/ ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic mode T1 \u0026amp; T2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 µs – 50 s, 1 µs resolution; timing accuracy 1 µs \/ 1 ms ±100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic rise\/fall slope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0006 A\/µs – 3 A\/µs (min. rise time 10 µs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kHz synchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpower protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 202 W, immediate ≥ 220 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 30.3 A, immediate ≥ 33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 152 V, immediate ≥ 165 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit (CC \/ CV \/ CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 30 A \/ 0 V \/ 60 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple display \/ waveform record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput terminal impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (110 V) \/ 0.25 A (220 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, USB Host, HANDLER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V \/ 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 × 88 × 372 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy temperature \/ calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ± 5 °C \/ 1 \/ year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Data_Sheet.pdf?v=1772202746\"\u003eUTL1020S Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Manuals.zip?v=1772202727\"\u003eUTL1020S User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530716411,"sku":"181500100145X","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTL1000S-1.png?v=1790709338"},{"product_id":"upo2204hd-200-mhz-4ch-12-bit-high-resolution-oscilloscope","title":"UPO2204HD 200 MHz 4Ch 12-Bit High-Resolution Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UNI-T UPO2204HD is a 200 MHz 4-channel 12-bit high-resolution oscilloscope built around the R12™ native 12-bit ADC. It samples at 2.5 GSa\/s with 100 Mpts memory depth standard, and Ultra Phosphor 3.0 acquisition pushes the waveform capture rate to 1,000,000 wfms\/s in sequence mode — sixteen times the vertical detail of an 8-bit scope, held at full bandwidth without ERES averaging or sample-rate trade-offs. The 10.1-inch capacitive multi-touch display, on-instrument 4 Mpts FFT, 9 standard protocol decoders, and built-in WebServer round out a six-instrument bench in a single chassis.\u003c\/p\u003e\n\u003cp\u003eThe four-channel UPO2204HD is the flagship of the UPO2000HD family — 200 MHz bandwidth, four simultaneous analog channels, 70 µVrms background noise, and 12-bit resolution at the full bandwidth without ERES or sample-rate compromise. For multi-rail switching-converter validation where high-side gate drive, low-side gate drive, switching node, and output ripple all need to be observed in one acquisition, this is the configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ 12-bit native ADC\u003c\/strong\u003e — 4,096 vertical levels held at the full 200 MHz bandwidth. No ERES averaging, no sample-rate trade-off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 4 analog channels\u003c\/strong\u003e — 2.5 GSa\/s real-time sample rate, 100 Mpts standard memory depth. Full-bandwidth 12-bit resolution with 70 µVrms noise floor for power-electronics work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s\u003c\/strong\u003e — Sequence-mode capture rate with 256-level grayscale persistence; surfaces intermittent and rare events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 instruments in one\u003c\/strong\u003e — Oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency meter, protocol analyzer, and optional power analysis on a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 protocol decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. No license fees, no time-boxed unlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touchscreen\u003c\/strong\u003e — 1280×800 multi-touch with pinch, drag, zoom, and rectangle-draw gestures. Mouse and keyboard supported in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Mpts enhanced FFT, 56 automated measurements, hardware mask test, zone trigger, ERES up to 4-bit\u003c\/strong\u003e — standard.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture, holding 4,096 quantization levels at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate without ERES averaging or sample-rate trade-off. Background noise is 70 µVrms at full bandwidth — low enough that the 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. For power-electronics validation where µV-scale ripple rides on a 400V bias rail, that headroom is the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's third-generation acquisition engine. Eight-channel parallel graphics processing at up to 20 Gbps drives a continuous capture rate of 250,000 wfms\/s, with sequence mode pushing the rate to 1,000,000 wfms\/s for trigger-conditioned events. 256-level grayscale persistence makes intermittent runts, glitches, and jitter visible as density gradients on screen rather than as occasional flashes that the eye misses. The same engine drives the digital trigger system — high sensitivity, low jitter, and zone trigger for isolating non-repeating signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e6 Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe UPO2204HD integrates six instrument functions into a single chassis: high-resolution oscilloscope, FFT spectrum analyzer with 4 Mpts and waterfall display, 4-digit digital voltmeter with DC\/AC RMS modes, 7-digit hardware frequency meter, 9-protocol decoder and trigger engine, and the optional 12-parameter power analysis suite. With four analog channels feeding all of them, multi-rail converter validation and multi-bus protocol correlation happen on the same instrument without the cabling and context-switching of separate boxes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSix instrument functions on a single bench chassis\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSix instrument functions on a single bench chassis\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory comes standard, not as an upgrade. At 2.5 GSa\/s that captures 40 ms of full-rate signal in a single acquisition — long enough to record a complete soft-start sequence, a fault-recovery transient, or a multi-frame burst without re-arming. Combined with hardware-accelerated mask testing, the 4-bit ERES enhanced-resolution mode, and uninterrupted recording of up to 125,000 frames, the deep memory turns long-running events from a sampling problem into a navigation problem.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eZoom across long sequences without losing detail\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eZoom across long sequences without losing detail\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2204HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. Each protocol supports both triggering and decoding, with event-list and search functions for navigating long captures. Decoded data appears alongside the analog waveform on the same trace — correlate a misbehaving I²C transaction with the supply-rail glitch that caused it, or align CAN-FD frames with the gate-drive event that triggered the fault recovery. No license fees, no time-boxed unlocks — the protocols are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional 12-Parameter Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds 12 measurement and analysis functions to the UPO2204HD: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. Connect a voltage probe and a current probe, select the analysis type, and the UPO2204HD renders the results without external post-processing — the metrics that drive switching-converter design decisions, on the bench, alongside the time-domain trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eStandard enhanced FFT analysis runs at up to 4 Mpts across all channels with a frequency range from 0 to 1.25 GHz, four traces, four detection modes, and a waterfall display for tracking spectrum changes over time. Auto, manual, and threshold marker modes locate harmonics, spurs, and EMI sources without switching to a separate spectrum analyzer. For pre-compliance spot checks during board bring-up and switching-noise investigation during converter design, the on-instrument FFT closes a common bench-workflow gap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 parameter measurements run continuously on every channel, with up to 27 measurements visible on screen and 39 single-channel parameters in the snapshot view. Statistics, histograms, and trend charts visualize each parameter's distribution over time. The new amplitude calculation strategy with top\/bottom and burst-parameter handling makes the numbers correct on signals where naive measurement engines pick the wrong reference levels. No post-processing, no spreadsheet export — the answer is on the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI and Full Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. The peripheral set includes USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail), and HDMI for projector or external-monitor display. SCPI is standard, the built-in WebServer enables browser-based remote control from a PC or mobile device, and firmware updates are free over the product's lifetime. For automated power-converter qualification benches, the SCPI command set drives waveform capture, mask-test pass\/fail, and long-record export from a Python or LabVIEW test harness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware \/ Analog Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Electronics Validation\u003c\/strong\u003e — GaN\/SiC half-bridge characterization, switching-node ringing analysis, and µV-scale ripple-on-bias measurement at 200 MHz bandwidth with 70 µVrms noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial-Bus Debug\u003c\/strong\u003e — Time-correlated analog and protocol-decode views in the same trace; 9 protocols included standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Integrity Spot Checks\u003c\/strong\u003e — On-instrument 4 Mpts FFT identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Capture Investigation\u003c\/strong\u003e — 100 Mpts memory plus 125,000-frame waveform recording captures complete soft-start, fault-recovery, and burst-mode events without re-arming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Rail Switching-Converter Validation\u003c\/strong\u003e — Four-channel 200 MHz configuration observes high-side gate drive, low-side gate drive, switching node, and output ripple in a single acquisition with 12-bit fidelity at 70 µVrms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 12-Parameter Power Analysis\u003c\/strong\u003e — Power quality, switching loss, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, transient response, and ripple analysis on the same instrument as the time-domain trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware-Accelerated Mask Testing\u003c\/strong\u003e — Pass\/fail validation against switching-waveform templates completes in seconds; AUX Out drives an alarm or DUT shutdown on out-of-mask events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Transient Capture\u003c\/strong\u003e — 100 Mpts captures complete soft-start and fault-recovery sequences in one trigger; 125,000-frame waveform recorder for repetitive burst-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2204HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e4 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? Compare with family-mates: UPO2202HD, UPO2104HD, UPO2074HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the UPO2204HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add power-supply analysis?\u003c\/p\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the touchscreen handle daily lab use?\u003c\/p\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UPO2204HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/p\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/p\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. See the series page to compare configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=109\"\u003eUPO2204HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUPO2000HD-PWR — Power Analysis Option for UPO2000HD\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530749179,"sku":"181100200139X","price":1092.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UPO2204HD-1.png?v=1790709339"},{"product_id":"utp3305-3ch-335w-32v-5a-linear-dc-power-supply","title":"UTP3305 3Ch 335W 32V\/5A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305 is a 335W three-channel linear bench supply for benches that need higher current than a 3A supply provides without giving up clean linear output. Two adjustable channels deliver 0–32V at 0–5A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and a front panel a first-year student gets back to default settings in under 30 seconds.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms — no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 10A), and a master-slave tracking mode keeps CH1 and CH2 synchronized when matched rails are needed for dual-supply analog work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 335W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–5A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs, and load regulation of CV ≤1×10⁻⁴ + 3 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover with Current Limit Protection\u003c\/strong\u003e — The supply transitions automatically between constant-voltage and constant-current operation when the load steps, protecting both the DUT and the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 10A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH1\/CH2 Master-Slave Tracking\u003c\/strong\u003e — Tracking mode synchronizes CH1 and CH2 for matched-rail testing (op-amp ±supplies, balanced analog stages, dual-supply mixed-signal designs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Bit Voltage and Current Dual Display\u003c\/strong\u003e — Independent voltage and current readouts per channel. No menus, no hidden settings — what you see is what the channel is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eBench Power That Stays Out of the Way\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3305 is the supply you put on a bench when the day's work is upstream of the power supply — circuit prototyping, board-level service, instructional labs where the lesson is signals or amplifiers, not procurement of a programmable instrument. The 5A current capability handles the higher-power loads where the UTP3303 runs out of headroom: small motors, transmitter front-ends, higher-current LED drive circuits, and parallel-mode 10A loads where two channels combine for current-hungry work.\u003c\/p\u003e\n\u003cp\u003eFor teaching labs and trade-school programs running 10–30 stations, this is the operational pitch: every student gets the same instrument with the same workflow, every shift. For service shops and small-team R\u0026amp;D benches, it's the supply you reach for when you don't want to think about the supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget, with 5A current handling the higher-power lab exercises (motor drive, power amplifiers, LED arrays).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003eDual 0–32V \/ 5A adjustable channels with master-slave tracking power op-amp ±supplies, audio amplifiers, and balanced analog stages with current headroom for class-AB and high-bias designs. Ripple under 1 mVrms keeps supply noise out of the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable bench supply for board-level service work where the device under test is a higher-current load — small motor drives, switch-mode supplies under test, automotive electronics. CV\/CC auto crossover handles unknown loads safely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMaker \u0026amp; Hobbyist Workshops\u003c\/h3\u003e\n\u003cp\u003eThree channels of clean linear power at a price point that makes sense for a workshop, with the current to drive higher-power projects: amateur radio rigs, EV-conversion bench testing, robotics prototyping. No software stack to maintain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3305 have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. The UTP3305 is a fully analog, knob-and-button bench supply — no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3305 and the UTP3303?\u003c\/p\u003e\n\u003cp\u003eOutput current. UTP3305 delivers 0–5A on CH1 and CH2 (335W total). UTP3303 delivers 0–3A on CH1 and CH2 (207W total). Voltage range, ripple, regulation, display, and feature set are otherwise identical between the two. Choose UTP3303 if 3A is enough; choose UTP3305 when you need to source above 3A on a single rail or up to 10A in parallel mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3305?\u003c\/p\u003e\n\u003cp\u003eThe UTP3305 ships with the instrument, power cord, output cables, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–5A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV ≤1×10⁻⁴ + 3 mV\u003cbr\u003eCC ≤2×10⁻⁴ + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Regulation Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV: 100 mV (typical)\u003cbr\u003eCC: 10 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Bias (CH1\/CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5×10⁻³ + 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-bit voltage and current dual display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel, CH1\/CH2 Master-Slave Tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 × 170 × 315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=43\"\u003eUTP3305 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530781947,"sku":"181730090193X","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTP3305-1.png?v=1790709339"},{"product_id":"ut-pd2500-2-5-ghz-active-differential-probe","title":"UT-PD2500 2.5 GHz Active Differential Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e2.5 GHz active differential oscilloscope probe with 10:1 attenuation and ±4V dynamic range. High-bandwidth differential measurement for power electronics, high-speed serial links, and switched-mode converter analysis. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5GHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 2.5GHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e±4 V Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530814715,"sku":"190500400010X","price":3779.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-PD1500_UT-PD2500.png?v=1790709340"},{"product_id":"utp3303-3ch-207w-32v-3a-linear-dc-power-supply","title":"UTP3303 3Ch 207W 32V\/3A Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3303 is a 207W three-channel linear bench supply for the kind of bench work where the supply itself shouldn't need its own learning curve. Two adjustable channels deliver 0–32V at 0–3A; a third channel provides a fixed 5V at 3A for logic-level power. Knobs, banana jacks, OVP\/OCP via current-limit protection, and the kind of front panel a first-year student gets back to default settings in under 30 seconds.\u003c\/p\u003e\n\u003cp\u003eLinear regulation keeps output ripple under 1mVrms — no switching artifacts, no EMI signature competing with the circuit you're actually trying to characterize. CH1 and CH2 combine in series (up to 64V) or parallel (up to 6A), and a master-slave tracking mode keeps CH1 and CH2 synchronized when matched rails are needed for dual-supply analog work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 207W Total\u003c\/strong\u003e — CH1 and CH2: 0–32V \/ 0–3A adjustable. CH3: fixed 5V \/ 3A for logic-level power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output with no switching frequency, no harmonic spurs, and load regulation of CV ≤1×10⁻⁴ + 3 mV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto CV\/CC Crossover with Current Limit Protection\u003c\/strong\u003e — The supply transitions automatically between constant-voltage and constant-current operation when the load steps, protecting both the DUT and the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries and Parallel Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 64V series or 6A parallel — front-panel selectable, no external wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH1\/CH2 Master-Slave Tracking\u003c\/strong\u003e — Tracking mode synchronizes CH1 and CH2 for matched-rail testing (op-amp ±supplies, balanced analog stages, dual-supply mixed-signal designs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Bit Voltage and Current Dual Display\u003c\/strong\u003e — Independent voltage and current readouts per channel. No menus, no hidden settings — what you see is what the channel is doing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput ON\/OFF Control\u003c\/strong\u003e — Front-panel master output button keeps you in command of when current actually leaves the supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKnob-and-Button Operation\u003c\/strong\u003e — No firmware to update, no PC software to install, no LAN port to configure. Front-panel only — designed to behave the same way on day one and year five.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eBench Power That Stays Out of the Way\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTP3303 is the supply you put on a bench when the day's work is upstream of the power supply — circuit prototyping, board-level service, instructional labs where the lesson is signals or amplifiers, not procurement of a programmable instrument. There's no SCPI command set to learn, no firmware path to get wrong before a class starts, and no LAN configuration page to ask IT about. There's a knob, a display, and CV\/CC auto-crossover protection that doesn't need a settings menu.\u003c\/p\u003e\n\u003cp\u003eFor teaching labs and trade-school programs running 10–30 stations, this is the operational pitch: every student gets the same instrument with the same workflow, every shift. For service shops and small-team R\u0026amp;D benches, it's the supply you reach for when you don't want to think about the supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Trade Schools\u003c\/h3\u003e\n\u003cp\u003ePer-station cost that lets a 20-bench classroom stay inside budget. Knob-and-button operation matches the curriculum-relevant skill: students learn measurement, not menu navigation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAnalog Bench Development\u003c\/h3\u003e\n\u003cp\u003eDual 0–32V adjustable channels with master-slave tracking power op-amp ±supplies, audio circuits, and balanced analog front-ends from one instrument. Ripple under 1 mVrms keeps supply noise out of the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eService \u0026amp; Repair\u003c\/h3\u003e\n\u003cp\u003eReliable everyday bench supply for board-level service work. CV\/CC auto crossover handles unknown loads safely, and the fixed 5V CH3 covers logic-level powering on legacy boards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMaker \u0026amp; Hobbyist Workshops\u003c\/h3\u003e\n\u003cp\u003eThree-channel linear bench supply at a price that makes sense for a workshop that isn't doing automated production test. Clean output, predictable behavior, no software stack to maintain.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTP3303 have USB or SCPI?\u003c\/p\u003e\n\u003cp\u003eNo. The UTP3303 is a fully analog, knob-and-button bench supply — no USB data interface, no LAN, no SCPI command set, no PC software. If your workflow needs SCPI control, the programmable counterparts in the UNI-T linear PSU family are the UDP3303C and UDP3305C (USB + RS-232) and the UDP3000S series (USB + LAN + LXI with web interface).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTP3303 and the UTP3305?\u003c\/p\u003e\n\u003cp\u003eOutput current. UTP3303 delivers 0–3A on CH1 and CH2 (207W total). UTP3305 delivers 0–5A on CH1 and CH2 (335W total). Voltage range, ripple, regulation, display, and feature set are otherwise identical between the two. Choose UTP3305 if you need to source above 3A on a single rail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. For analog bench work, audio circuits, low-noise sensor development, and any precision measurement where supply noise shows up in the result, the difference is measurable. The trade-off is lower efficiency and more heat, which at this power level on a bench is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UTP3303?\u003c\/p\u003e\n\u003cp\u003eThe UTP3303 ships with the instrument, power cord, output cables, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP3303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (CH1, CH2 adjustable; CH3 fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–32V\u003cbr\u003eCH3: 5V (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH1, CH2: 0–3A\u003cbr\u003eCH3: 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e207W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV ≤1×10⁻⁴ + 3 mV\u003cbr\u003eCC ≤2×10⁻⁴ + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage: ≤1 mVrms\u003cbr\u003eCurrent: ≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Regulation Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCV: 100 mV (typical)\u003cbr\u003eCC: 10 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTracking Bias (CH1\/CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5×10⁻³ + 10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-bit voltage and current dual display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent, Series, Parallel, CH1\/CH2 Master-Slave Tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent limit protection with auto CV\/CC crossover, output ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTBF ≥ 2,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V \/ 230V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×D×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 × 170 × 315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=43\"\u003eUTP3303 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530847483,"sku":"181730090200X","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTP3305-1_4f1b26b5-14e6-40b3-9c6e-ffbea0c0f826.png?v=1790709340"},{"product_id":"utl1020s-e-200w-programmable-dc-electronic-load","title":"UTL1020S-E 200W Programmable DC Electronic Load","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTL1020S-E\u003c\/strong\u003e is a single-channel programmable DC electronic load rated 200 W, 0–150 V, 0–30 A. It runs four constant modes — CC, CV, CR, CP — plus eleven additional test modes including dynamic, OVP, OCP, time, CR-LED, battery, automatic list, short-circuit, load-effect, combination, and list, for 15 test modes in total. Synchronous sampling reaches 500 kHz with high-performance DSP processing and a self-adaptive voltage and current waveform display on the 4.3-inch TFT LCD.\u003c\/p\u003e\n\u003cp\u003eDynamic mode pulls load at up to 50 kHz so current and voltage peaks — Vpp and Ipp — can be observed directly. The load also provides on-screen ripple measurement, a rear-panel Sense terminal for remote voltage compensation, and SCPI remote control over RS232 with a HANDLER interface and USB Host port for data logging and automated production test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — 200 W 15-Mode Load\u003c\/h2\u003e\n\u003cp\u003eTwo 200 W models share the same load architecture, the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. They differ in one axis only: measurement resolution.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e (high-resolution)\u003c\/td\u003e\n\u003ctd\u003eCurrent resolution 0.01 mA \/ 0.1 mA, voltage readback 0.01 mV \/ 0.1 mV — finer metering for precision readback work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e (standard resolution)\u003c\/td\u003e\n\u003ctd\u003eSame 200 W load, same 15 modes; current resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV. The lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThis page describes the \u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e. Capability, test modes, protection, and interfaces below apply to both 200 W models; the Specifications table lists this model's resolution figures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 W, 0–150 V, 0–30 A single-channel load\u003c\/strong\u003e — CC, CV, CR, CP basic modes with dual high\/low input ranges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 test modes\u003c\/strong\u003e — CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 kHz synchronous sampling\u003c\/strong\u003e — high sampling density for accurate transient capture and reduced measurement omission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 kHz dynamic mode\u003c\/strong\u003e — programmable rise\/fall slope (0.0006–3 A\/µs) simulates real changing load conditions; Vpp \/ Ipp observed directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery test with charge and discharge curves\u003c\/strong\u003e — records both charge and discharge curves for battery characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic list test\u003c\/strong\u003e — up to 200-step programmable multi-mode sequences for automated, repeatable testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-screen ripple measurement and real-time waveform\u003c\/strong\u003e — ripple readout in the screen corner; [WAVE] key shows live V\/I waveform without an external oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote compensation (Sense terminal)\u003c\/strong\u003e — rear-panel Sense terminal eliminates lead voltage-drop error at high current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS232 \/ USB Host \/ HANDLER, SCPI protocol\u003c\/strong\u003e — PC software control, USB-drive screenshots and list import\/export, HANDLER for ATE integration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCurrent resolution 0.1 mA \/ 1 mA, voltage readback 0.1 mV \/ 1 mV, 16-bit CR, 3 years standard + 2 year extension.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTL1020S-E Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/h3\u003e\n\u003cp\u003eFour constant modes — CC (constant current), CV (constant voltage), CR (constant resistance), CP (constant power) — plus eleven more: dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short-circuit, load effect, combination, and list. The CR-LED mode simulates real LED forward-voltage behavior for LED-driver testing; battery mode records charge and discharge curves; combination mode pairs two basic modes (CR+CC, CV+CR, CV+CC) for more realistic DUT conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S-E 15 test modes covering power, battery, and LED-driver validation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S-E dynamic mode 50 kHz transient load simulation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/h3\u003e\n\u003cp\u003eDynamic mode pulls load at frequencies up to 50 kHz with T1\/T2 timing from 10 µs to 50 s (1 µs resolution) and a programmable rising\/falling current slope of 0.0006 A\/µs to 3 A\/µs. The current and voltage peak waveforms are observed directly on screen with Vpp and Ipp measurement, so transient response and overshoot of the device under test can be characterized without a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBattery Test with Charge and Discharge Curves\u003c\/h3\u003e\n\u003cp\u003eBattery mode performs constant-current or constant-power discharge testing and records the full discharge curve. The UTL1020S-E captures both the discharge and the charging curve, so capacity, internal-resistance behavior, and cycle characteristics are traceable from a single instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S-E battery test recording charge and discharge curves\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S-E automatic list test with up to 200 programmable steps\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/h3\u003e\n\u003cp\u003eThe automatic list test runs editable multi-step, multi-mode sequences with up to 200 steps. Set the appropriate load value and mode for each step and the list executes the full test process automatically. List files save to internal memory or a USB drive and can be imported, so a validated production-test sequence transfers between units quickly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/h3\u003e\n\u003cp\u003eRipple is measured and displayed directly in the corner of the screen, replacing a separate oscilloscope measurement for routine power-supply ripple checks. Pressing the [WAVE] function key shows the live voltage and current waveform, with the self-adaptive display scaling automatically to the signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S-E on-screen ripple measurement and real-time waveform display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S-E OVP and OCP protection-function testing\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOVP and OCP Protection Testing\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eOVP and OCP Protection Testing\u003c\/h3\u003e\n\u003cp\u003eSet the protection threshold according to the device under test and the UTL1020S-E measures the protection function and the protection response time. Overvoltage protection triggers with delayed protection at ≥ 152 V and immediate protection at ≥ 165 V; overcurrent protection at ≥ 30.3 A delayed and ≥ 33 A immediate; overpower at ≥ 202 W delayed and ≥ 220 W immediate. Instrument protection can also be turned off to prevent false alarms during characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLoad Effect Test\u003c\/h3\u003e\n\u003cp\u003eThe load effect test automatically measures and calculates load-regulation results from the configured test values, so power-supply load regulation is characterized without manual point-by-point measurement and calculation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E automated load effect \/ load regulation test\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLoad Effect Test\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E time test measuring power-supply rise and fall time\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/figcaption\u003e\n\u003c\/figure\u003e\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/h3\u003e\n\u003cp\u003eTime test measures the rise and fall times of the device under test against configured thresholds, with 1 µs timing resolution and ±100 ppm timing accuracy, for power-supply turn-on \/ turn-off and transient-timing characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe 200 W 15-mode envelope — CC\/CV\/CR\/CP plus dynamic, battery, list, protection, load-effect, and combination modes with 500 kHz sampling — covers R\u0026amp;D and production test for power electronics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching power-supply and adapter test\u003c\/strong\u003e — load regulation, ripple, transient response, and protection-function verification from one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery and battery-pack characterization\u003c\/strong\u003e — charge and discharge curve recording for capacity, BMS, and cycle testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED-driver validation\u003c\/strong\u003e — CR-LED mode simulates real LED forward-voltage behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger and power-bank testing\u003c\/strong\u003e — automatic list sequences for repeatable multi-step production test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC-DC converter and module test\u003c\/strong\u003e — dynamic loading at up to 50 kHz to characterize transient overshoot and recovery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated production test (ATE)\u003c\/strong\u003e — SCPI over RS232 plus HANDLER interface for test-line integration; list import\/export for fast line setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eRS232 communication cable\u003c\/li\u003e\n\u003cli\u003ePlug-in terminal block (5.08-2P) and screw-free spring terminal block (2.54-6P)\u003c\/li\u003e\n\u003cli\u003eSpare fuse (2 pcs)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration and multi-language safety precautions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Test Leads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0615-OO\u003c\/strong\u003e — double O-type terminal, 60 A \/ 1.5 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0320-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0312-UU\u003c\/strong\u003e — double U-type terminal, 30 A \/ 1.2 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BB\u003c\/strong\u003e — double fold-insert, 10 A \/ 1 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-L0110-BU\u003c\/strong\u003e — fold-insert to U-type, 10 A \/ 1 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUTL1000S Series\u003c\/h3\u003e\n\u003cp\u003eFour models share the same chassis, 15 test modes, 500 kHz sampling, accuracy class, and 0–150 V \/ 0–30 A input envelope:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S\u003c\/strong\u003e — 200 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1020S-E\u003c\/strong\u003e — 200 W, standard resolution (this product)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S\u003c\/strong\u003e — 400 W, high-resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTL1040S-E\u003c\/strong\u003e — 400 W, standard resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the UTL1020S-E and the UTL1020S?\u003c\/p\u003e\n\u003cp\u003eBoth are 200 W loads with the same 15 test modes, the same accuracy class, and the same 0–150 V \/ 0–30 A input envelope. The difference is measurement resolution: the UTL1020S-E resolves current to 0.1 mA \/ 1 mA and voltage readback to 0.1 mV \/ 1 mV across its low and high ranges. The high-resolution model is suited to precision readback work; the standard-resolution model is the lower-cost choice when fine readback resolution is not the deciding factor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow many test modes does the UTL1020S-E have, and what are they?\u003c\/p\u003e\n\u003cp\u003e15 modes: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list. The four constant modes (CC, CV, CR, CP) cover standard load testing; the remaining modes add transient, protection, battery, LED-driver, automated, and combination testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UTL1020S-E test batteries?\u003c\/p\u003e\n\u003cp\u003eYes. Battery mode performs discharge testing and records both the discharge and the charging curve, so capacity and cycle behavior are traceable from the instrument — useful for battery-pack, BMS, and power-bank validation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes it measure ripple without an oscilloscope?\u003c\/p\u003e\n\u003cp\u003eYes. Ripple is measured and displayed in the corner of the screen, and the [WAVE] key shows the live voltage and current waveform, so routine ripple and waveform checks do not require a separate oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the Sense terminal for?\u003c\/p\u003e\n\u003cp\u003eAt high current, lead resistance creates a voltage drop between the load and the device under test. The rear-panel Sense terminal measures voltage at the DUT output terminal directly (remote compensation), so the displayed voltage reflects the DUT rather than the voltage after the test leads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow is the UTL1020S-E controlled remotely?\u003c\/p\u003e\n\u003cp\u003eOver RS232 using the standard SCPI protocol with the included PC data-acquisition software. A HANDLER interface supports automated test-line integration, and a USB Host port accepts a USB drive for screenshots and for importing or exporting list files.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_test-modes_sq.jpg?v=1770678169\" alt=\"UTL1020S-E 15 test modes covering power, battery, and LED-driver validation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 Test Modes for Power, Battery, and LED-Driver Validation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_dynamic-testing_sq.jpg?v=1770678169\" alt=\"UTL1020S-E dynamic mode 50 kHz transient load simulation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDynamic Mode — 50 kHz Transient Load Simulation\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_battery-testing.gif\" alt=\"UTL1020S-E battery test recording charge and discharge curves\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBattery Test with Charge and Discharge Curves\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_auto-list.gif\" alt=\"UTL1020S-E automatic list test with up to 200 programmable steps\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAutomatic List Test — 200-Step Programmable Sequences\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ripple-measurement_sq.jpg?v=1770678169\" alt=\"UTL1020S-E on-screen ripple measurement and real-time waveform display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOn-Screen Ripple Measurement and Real-Time Waveform\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_ovp_sq.jpg?v=1770678169\" alt=\"UTL1020S-E OVP and OCP protection-function testing\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOVP and OCP Protection Testing\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_load-effect-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E automated load effect \/ load regulation test\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLoad Effect Test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_time-test_sq.jpg?v=1770678169\" alt=\"UTL1020S-E time test measuring power-supply rise and fall time\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTime Test — Rise and Fall Time of the Power Supply\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–15 V (low) \/ 0–150 V (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3 A (low) \/ 0–30 A (high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum operating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 V ± 0.1 V at 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCV mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.1–150 V, resolution 1 mV, accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCC mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResolution 0.1 mA \/ 1 mA (low \/ high), accuracy ±(0.03% + 0.05% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCR mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 0.05 Ω – 10 kΩ, resolution 16 bits, accuracy (0.1 + 0.01R)%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCP mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRange 200 W, resolution 10 mW, accuracy ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CC\/CP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV \/ 1 mV (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback voltage resolution (CV\/CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback current resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA \/ 1 mA (low \/ high)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadback accuracy (V \/ I \/ P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.02% + 0.3% FS) \/ ±(0.03% + 0.05% FS) \/ ±(0.1% + 0.1% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic mode T1 \u0026amp; T2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 µs – 50 s, 1 µs resolution; timing accuracy 1 µs \/ 1 ms ±100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic rise\/fall slope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0006 A\/µs – 3 A\/µs (min. rise time 10 µs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 kHz synchronous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverpower protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 202 W, immediate ≥ 220 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 30.3 A, immediate ≥ 33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelay ≥ 152 V, immediate ≥ 165 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit (CC \/ CV \/ CR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 30 A \/ 0 V \/ 60 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15: CC, CV, CR, CP, dynamic, OVP, time, OCP, CR-LED, battery, automatic list, short circuit, load effect, combination, list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple display \/ waveform record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput terminal impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A (110 V) \/ 0.25 A (220 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, USB Host, HANDLER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 V \/ 220 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215 × 88 × 372 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.73 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C – 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy temperature \/ calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ± 5 °C \/ 1 \/ year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Data_Sheet.pdf?v=1772202746\"\u003eUTL1020S-E Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTL1000S_Series_DC_Electronic_Load_-_Manuals.zip?v=1772202727\"\u003eUTL1020S-E User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530880251,"sku":"181500100142X","price":439.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTL1000S-1_6c2bcd7b-2cb7-44a7-942c-91abe9254386.png?v=1790709341"},{"product_id":"upo2202hd-200-mhz-2ch-12-bit-high-resolution-oscilloscope","title":"UPO2202HD 200 MHz 2Ch 12-Bit High-Resolution Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UNI-T UPO2202HD is a 200 MHz 2-channel 12-bit high-resolution oscilloscope built around the R12™ native 12-bit ADC. It samples at 2.5 GSa\/s with 100 Mpts memory depth standard, and Ultra Phosphor 3.0 acquisition pushes the waveform capture rate to 1,000,000 wfms\/s in sequence mode — sixteen times the vertical detail of an 8-bit scope, held at full bandwidth without ERES averaging or sample-rate trade-offs. The 10.1-inch capacitive multi-touch display, on-instrument 4 Mpts FFT, 9 standard protocol decoders, and built-in WebServer round out a six-instrument bench in a single chassis.\u003c\/p\u003e\n\u003cp\u003eFor power-electronics validation at the top of this family's bandwidth, the UPO2202HD pairs 200 MHz analog bandwidth with 70 µVrms background noise so that 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. On a GaN\/SiC half-bridge measurement where switching-node ringing and DC-bias content compete for vertical headroom, the resolution gain is the difference between a debug session and an afternoon.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ 12-bit native ADC\u003c\/strong\u003e — 4,096 vertical levels held at the full 200 MHz bandwidth. No ERES averaging, no sample-rate trade-off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 MHz bandwidth, 2 analog channels\u003c\/strong\u003e — 2.5 GSa\/s real-time sample rate, 100 Mpts standard memory depth. Full-bandwidth 12-bit resolution with 70 µVrms noise floor for power-electronics work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s\u003c\/strong\u003e — Sequence-mode capture rate with 256-level grayscale persistence; surfaces intermittent and rare events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6 instruments in one\u003c\/strong\u003e — Oscilloscope, spectrum analyzer, digital voltmeter, hardware frequency meter, protocol analyzer, and optional power analysis on a single chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 protocol decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. No license fees, no time-boxed unlocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touchscreen\u003c\/strong\u003e — 1280×800 multi-touch with pinch, drag, zoom, and rectangle-draw gestures. Mouse and keyboard supported in parallel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 Mpts enhanced FFT, 56 automated measurements, hardware mask test, zone trigger, ERES up to 4-bit\u003c\/strong\u003e — standard.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit ADC at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T's native 12-bit ADC architecture, holding 4,096 quantization levels at the full 200 MHz bandwidth and 2.5 GSa\/s sample rate without ERES averaging or sample-rate trade-off. Background noise is 70 µVrms at full bandwidth — low enough that the 12-bit resolution actually shows up on the screen instead of being buried in the noise floor. For power-electronics validation where µV-scale ripple rides on a 400V bias rail, that headroom is the measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206878\/UPO2000HD_12bit.png\" alt=\"12-bit resolution\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e4,096-level quantization holds at full bandwidth\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 1,000,000 wfms\/s Acquisition\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T's third-generation acquisition engine. Eight-channel parallel graphics processing at up to 20 Gbps drives a continuous capture rate of 250,000 wfms\/s, with sequence mode pushing the rate to 1,000,000 wfms\/s for trigger-conditioned events. 256-level grayscale persistence makes intermittent runts, glitches, and jitter visible as density gradients on screen rather than as occasional flashes that the eye misses. The same engine drives the digital trigger system — high sensitivity, low jitter, and zone trigger for isolating non-repeating signals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753215911\/UPO2000HD_Ultra-Phosphor-3.gif\" alt=\"Ultra Phosphor 3.0 acquisition\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eHigh-speed rendering surfaces fast or infrequent anomalies\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e6 Instruments in One\u003c\/h3\u003e\n\u003cp\u003eThe UPO2202HD integrates six instrument functions into a single chassis: high-resolution oscilloscope, FFT spectrum analyzer with 4 Mpts and waterfall display, 4-digit digital voltmeter with DC\/AC RMS modes, 7-digit hardware frequency meter, 9-protocol decoder and trigger engine, and the optional 12-parameter power analysis suite. For 2-channel benchwork where rack space and budget both matter, the consolidation eliminates instrument switching and context loss during a single debug session.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSix instrument functions on a single bench chassis\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_6-in-1.png\" alt=\"Six instruments in one chassis\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSix instrument functions on a single bench chassis\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eDeep Memory — 100 Mpts Standard\u003c\/h3\u003e\n\u003cp\u003e100 Mpts of memory comes standard, not as an upgrade. At 2.5 GSa\/s that captures 40 ms of full-rate signal in a single acquisition — long enough to record a complete soft-start sequence, a fault-recovery transient, or a multi-frame burst without re-arming. Combined with hardware-accelerated mask testing, the 4-bit ERES enhanced-resolution mode, and uninterrupted recording of up to 125,000 frames, the deep memory turns long-running events from a sampling problem into a navigation problem.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eZoom across long sequences without losing detail\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206877\/UPO2000HD_Memory_Depth.png\" alt=\"Deep memory navigation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eZoom across long sequences without losing detail\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eAll Protocols Included Standard\u003c\/h3\u003e\n\u003cp\u003eNine serial-bus protocol decoders are included with every UPO2202HD: RS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio. Each protocol supports both triggering and decoding, with event-list and search functions for navigating long captures. Decoded data appears alongside the analog waveform on the same trace — correlate a misbehaving I²C transaction with the supply-rail glitch that caused it, or align CAN-FD frames with the gate-drive event that triggered the fault recovery. No license fees, no time-boxed unlocks — the protocols are standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_Protocols.png\" alt=\"Standard protocol decoding\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine serial-bus protocols decoded alongside the analog trace\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional 12-Parameter Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds 12 measurement and analysis functions to the UPO2202HD: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. Connect a voltage probe and a current probe, select the analysis type, and the UPO2202HD renders the results without external post-processing — the metrics that drive switching-converter design decisions, on the bench, alongside the time-domain trace.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Pwr.png\" alt=\"Power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePower quality, switching loss, ripple, and SOA on the same instrument\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — FFT to 4 Mpts\u003c\/h3\u003e\n\u003cp\u003eStandard enhanced FFT analysis runs at up to 4 Mpts across all channels with a frequency range from 0 to 1.25 GHz, four traces, four detection modes, and a waterfall display for tracking spectrum changes over time. Auto, manual, and threshold marker modes locate harmonics, spurs, and EMI sources without switching to a separate spectrum analyzer. For pre-compliance spot checks during board bring-up and switching-noise investigation during converter design, the on-instrument FFT closes a common bench-workflow gap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206871\/UPO2000HD_Spectrum-Analyzer.png\" alt=\"Built-in FFT spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFFT with waterfall and four traces at up to 4 Mpts\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e56 Automated Measurements with Statistics\u003c\/h3\u003e\n\u003cp\u003e56 parameter measurements run continuously on every channel, with up to 27 measurements visible on screen and 39 single-channel parameters in the snapshot view. Statistics, histograms, and trend charts visualize each parameter's distribution over time. The new amplitude calculation strategy with top\/bottom and burst-parameter handling makes the numbers correct on signals where naive measurement engines pick the wrong reference levels. No post-processing, no spreadsheet export — the answer is on the screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206872\/UPO2000HD_56-measurements.png\" alt=\"56 automated measurements\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMeasure, visualize, and track parameter distributions on screen\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI and Full Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 10.1-inch 1280×800 capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. The peripheral set includes USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail), and HDMI for projector or external-monitor display. SCPI is standard, the built-in WebServer enables browser-based remote control from a PC or mobile device, and firmware updates are free over the product's lifetime. For automated power-converter qualification benches, the SCPI command set drives waveform capture, mask-test pass\/fail, and long-record export from a Python or LabVIEW test harness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1753206868\/UPO2000HD_Mask.jpg\" alt=\"Touch UI and connectivity\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-touch gestures with full connectivity and WebServer access\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D Engineer (Embedded \/ Hardware \/ Analog Design)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Electronics Validation\u003c\/strong\u003e — GaN\/SiC half-bridge characterization, switching-node ringing analysis, and µV-scale ripple-on-bias measurement at 200 MHz bandwidth with 70 µVrms noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial-Bus Debug\u003c\/strong\u003e — Time-correlated analog and protocol-decode views in the same trace; 9 protocols included standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal-Integrity Spot Checks\u003c\/strong\u003e — On-instrument 4 Mpts FFT identifies harmonics, clock spurs, and EMI sources without switching to a separate spectrum analyzer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Capture Investigation\u003c\/strong\u003e — 100 Mpts memory plus 125,000-frame waveform recording captures complete soft-start, fault-recovery, and burst-mode events without re-arming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Electronics Engineer\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFocused Switching-Node Characterization\u003c\/strong\u003e — 200 MHz bandwidth with 70 µVrms noise floor resolves GaN\/SiC switching-edge ringing and µV-scale ripple in the same acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 12-Parameter Power Analysis\u003c\/strong\u003e — Power quality, switching loss, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, transient response, and ripple analysis on the same instrument as the time-domain trace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware-Accelerated Mask Testing\u003c\/strong\u003e — Pass\/fail validation against switching-waveform templates completes in seconds; AUX Out drives an alarm or DUT shutdown on out-of-mask events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Transient Capture\u003c\/strong\u003e — 100 Mpts captures complete soft-start and fault-recovery sequences in one trigger; 125,000-frame waveform recorder for repetitive burst-mode operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded with the Instrument\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO2202HD oscilloscope\u003c\/li\u003e\n\u003cli\u003e2 × passive probes (1:1 \/ 10:1 switchable, bandwidth matched to instrument)\u003c\/li\u003e\n\u003cli\u003eUSB cable (USB-A to USB-B)\u003c\/li\u003e\n\u003cli\u003ePower cord (region-appropriate)\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO2000HD-PWR — optional 12-parameter power-analysis package activation\u003c\/li\u003e\n\u003cli\u003e\nUT-P07A — 500 MHz passive probe for higher-bandwidth applications\u003c\/li\u003e\n\u003cli\u003e\nUT-P20, UT-P21, UT-V23 — high-voltage passive probes\u003c\/li\u003e\n\u003cli\u003e\nUT-P30, UT-P31, UT-P32, UT-P33 — differential probes for floating measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-P40, UT-P41, UT-P42, UT-P43, UT-P44 — current probes for power-stage and switching-loss measurement\u003c\/li\u003e\n\u003cli\u003e\nUT-ISOT — isolation transformer for safe line-powered measurements\u003c\/li\u003e\n\u003cli\u003e\nUT-M13X — oscilloscope demo board for protocol decoding practice and curriculum modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different bandwidth or channel-count? Compare with family-mates: UPO2204HD, UPO2102HD, UPO2072HD.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the UPO2202HD?\u003c\/p\u003e\n\u003cp\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, and Audio decoding are included standard at no additional cost. All nine supported protocols are available out of the box — no optional licenses required, no time-boxed unlocks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the advantage of native 12-bit resolution?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical levels compared to 256 for an 8-bit scope — sixteen times greater detail. This reveals small signals riding on large ones, reduces quantization noise, and improves measurement accuracy on low-amplitude signals like power-supply ripple, sensor outputs, and precision analog circuits. R12™ holds the 12-bit resolution at the full bandwidth and sample rate, with no ERES averaging or sample-rate trade-off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add power-supply analysis?\u003c\/p\u003e\n\u003cp\u003eYes. The optional power-analysis package adds 12 measurements: power quality, harmonic analysis, current harmonics, R\u003csub\u003eDS(on)\u003c\/sub\u003e, switching loss, slew rate, safe operating area, modulation analysis, output ripple, startup\/shutdown time, transient response, and power efficiency. The UPO2000HD-PWR activation unlocks the package on any UPO2000HD-series oscilloscope.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the touchscreen handle daily lab use?\u003c\/p\u003e\n\u003cp\u003eThe 10.1-inch capacitive multi-touch display supports pinch, drag, zoom, rectangle-draw, and edit gestures alongside the traditional knobs and one-touch front-panel keys. Mouse and keyboard are supported in parallel. For lab settings where students or engineers cycle through the instrument frequently, the gesture set is familiar from consumer devices; for production-style workflows where physical controls are preferred, the front panel still does what front panels do.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow does the UPO2202HD compare to 8-bit oscilloscopes at similar bandwidth?\u003c\/p\u003e\n\u003cp\u003eThe 12-bit ADC delivers 16× the vertical resolution of an 8-bit scope at the same bandwidth, with no ERES averaging or sample-rate trade-off. Low-amplitude signals — switching ripple, sensor outputs, precision analog circuits — that 8-bit scopes flatten into quantization noise show up clearly on the 12-bit display. For analog precision work and switching-converter validation, the resolution advantage is structural, not a marketing comparison.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the firmware field-upgradable?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates are free over the product's lifetime and install via USB drive or LAN transfer. Optional license unlocks (such as the power-analysis package) have no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the instrument be controlled from a PC or from a browser?\u003c\/p\u003e\n\u003cp\u003eBoth. SCPI is supported standard via USB Device or LAN for automated test scripts and PC-side instrument-management software. The built-in WebServer enables direct browser-based control from a PC or mobile device on the same network — no PC-side software install required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003ePart of the UPO2000HD oscilloscope series. All models share the R12™ native 12-bit ADC, 2.5 GSa\/s sample rate, 100 Mpts memory, Ultra Phosphor 3.0 acquisition, and 9 standard protocol decoders. Bandwidth options span 70 \/ 100 \/ 200 MHz; channel options are 2-channel and 4-channel. See the series page to compare configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits (R12™ native)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 wfms\/s (sequence mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touchscreen, 1280×800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, code pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone Trigger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — 2 zones, must-intersect \/ must-not-intersect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI, CAN, CAN-FD, LIN, FlexRay, SENT, Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In FFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — up to 4 Mpts, 0 to 1.25 GHz, 4 traces, waterfall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Power Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — 12 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Spectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard FFT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Voltmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-digit; DC, AC RMS, AC+DC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Meter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 with statistics, histogram, and trend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eERES (Enhanced Resolution)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMask Testing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware-accelerated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 125,000 frames; USB export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host \/ USB Device \/ LAN \/ EXT Trig \/ AUX Out \/ HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI standard; built-in WebServer (browser access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=109\"\u003eUPO2202HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUPO2000HD-PWR — Power Analysis Option for UPO2000HD\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530913019,"sku":"181100200140X","price":924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UPO2202HD-1.png?v=1790709344"},{"product_id":"ut-p30-100-mhz-10-1-100-1-differential-oscilloscope-probe","title":"UT-P30 100 MHz 10:1\/100:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100 MHz differential oscilloscope probe (10:1\/100:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:1\/100:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10:1, 100:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 MΩ \/ 1.3 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P30_User_Manual.pdf\"\u003eUT-P30 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530945787,"sku":"190500300014","price":399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P30_1_sq.jpg?v=1790709344"},{"product_id":"ute9811-600v-20a-harmonic-analysis-digital-power-meter","title":"UTE9811+ 600V\/20A Harmonic-Analysis Digital Power Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE9811+\u003c\/strong\u003e is a compact single-phase digital power meter measuring 3V – 600V \/ 5mA – 20A to 1W – 12kW. It performs PLL-synchronized harmonic analysis to the 50th order with THD and crest-factor measurement — built for power-quality and distortion work.\u003c\/p\u003e\n\u003cp\u003eIt is built for bench and in-rack power measurement on power-supply, converter and appliance-energy work, with RS-232 and RS-485 for datalogging and integration into automated test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE9800+ Series\u003c\/h2\u003e\n\u003cp\u003eThe UTE9800+ name covers three distinct compact power meters. Compare the full series before selecting:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003ccol style=\"width:30%\"\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eWhat Sets It Apart\u003c\/th\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eV \/ A Range\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9802+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC \/ DC \/ AC+DC True RMS\u003c\/td\u003e\n\u003ctd\u003eTrue power, V, A, W, PF, Hz\u003c\/td\u003e\n\u003ctd\u003e3V – 600V \/ 0.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9806+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApparent power + V \/ PF alarm limits\u003c\/td\u003e\n\u003ctd\u003eV, A, P, VA, PF, Hz, Vpeak, Apeak\u003c\/td\u003e\n\u003ctd\u003e0.5V – 600V \/ 0.05mA – 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE9811+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50th-order harmonic analysis (PLL)\u003c\/td\u003e\n\u003ctd\u003eV, A, W, PF, Hz, THD, CF\u003c\/td\u003e\n\u003ctd\u003e3V – 600V \/ 5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe three UTE9800+ models are not a progression — each is a distinct instrument chosen by what you need to measure: mixed-mode true RMS (9802+), limit\/alarm testing (9806+), or harmonic and distortion analysis (9811+).\u003c\/p\u003e\n\u003cp\u003eFor single-phase high-voltage bench measurement or three-phase work, see the UTE310 Series (600 V \/ 1000 V single-phase) and the UTE323 Series (3-channel three-phase) — distinct higher-tier instrument lines.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003e50th-order harmonic analysis, PLL-synchronized\u003c\/li\u003e\n\u003cli\u003eTHD and crest-factor (CF) measurement\u003c\/li\u003e\n\u003cli\u003eTrue power, V, A, W, PF and frequency\u003c\/li\u003e\n\u003cli\u003e3V – 600V \/ 5mA – 20A measurement range, to 1W – 12kW\u003c\/li\u003e\n\u003cli\u003eVoltage resolution 0.01V; current resolution 1mA\u003c\/li\u003e\n\u003cli\u003eMeasurement bandwidth 40Hz – 70Hz\u003c\/li\u003e\n\u003cli\u003eRS-232 and RS-485 for datalogging and ATE integration\u003c\/li\u003e\n\u003cli\u003e4.3-inch LCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE9811+ Details\u003c\/h2\u003e\n\u003ch3\u003e50th-Order Harmonic Analysis, PLL-Synchronized\u003c\/h3\u003e\n\u003cp\u003eThe UTE9811+ performs phase-locked-loop synchronized harmonic analysis to the 50th order, with total harmonic distortion (THD) and crest-factor measurement — the data set for power-quality and distortion assessment on non-linear loads.\u003c\/p\u003e\n\u003ch3\u003eRS-232 \/ RS-485 Communication\u003c\/h3\u003e\n\u003cp\u003eBoth RS-232 and RS-485 are standard, with SCPI and Modbus support, for datalogging and integration into multi-drop production-line monitoring or an automated test framework.\u003c\/p\u003e\n\u003ch3\u003eCompact Bench \/ In-Rack Form Factor\u003c\/h3\u003e\n\u003cp\u003eThe compact chassis fits a test bench or an instrument rack and leaves the front-panel reading clear for V, A, W, PF and frequency at a glance during a measurement run.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003ePower-Quality \u0026amp; Harmonic Work\u003c\/h3\u003e\n\u003cp\u003ePLL-synchronized 50th-order harmonic analysis with THD and crest factor quantifies distortion on rectifier and PFC front ends for power-quality assessment.\u003c\/p\u003e\n\u003ch3\u003ePre-Compliance Distortion Screening\u003c\/h3\u003e\n\u003cp\u003eBench harmonic and THD screening flags distortion problems early in design verification, before formal compliance testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables and the UTE-M01-US North-American test fixture support safe connection to standard plug loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow does the UTE9811+ differ from the other UTE9800+ models?\u003c\/h3\u003e\n\u003cp\u003eEach UTE9800+ model is a distinct instrument: the UTE9802+ adds AC\/DC\/AC+DC true-RMS modes, the UTE9806+ adds apparent power and limit alarms, and the UTE9811+ adds 50th-order harmonic analysis. They are chosen by measurement need, not as a tier progression.\u003c\/p\u003e\n\u003ch3\u003eDoes it have a computer interface?\u003c\/h3\u003e\n\u003cp\u003eYes — RS-232 and RS-485 with SCPI and Modbus support, for datalogging and automated test.\u003c\/p\u003e\n\u003ch3\u003eIs this a three-phase meter?\u003c\/h3\u003e\n\u003cp\u003eNo. The UTE9800+ models are single-phase (1P2W). For three-phase measurement, see the UTE323 Series.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE9811+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3V – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40Hz – 70Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV, A, W, PF, Hz, THD, CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st – 50th (PLL-synced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.3-inch LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=64\"\u003eUTE9811+ Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eRS232 Cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601530978555,"sku":"182700700012X","price":339.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTE9811_-1.png?v=1790709345"},{"product_id":"ut-p4150-12-mhz-high-frequency-dc-ac-current-probe","title":"UT-P4150 12 MHz High-Frequency DC\/AC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e12MHz bandwidth, A AC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mV\/A (30 A range) \/ 100 mA\/A (150 A range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531011323,"sku":"190500100148X","price":2529.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P4150-3_sq.jpg?v=1790709345"},{"product_id":"ut-p32-50-mhz-100-1-1000-1-differential-oscilloscope-probe","title":"UT-P32 50 MHz 100:1\/1000:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e50 MHz differential oscilloscope probe (100:1\/1000:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e50MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 50MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100:1\/1000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3000Vpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 7ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 50 Hz, \u0026gt; 60 dB @ 100 kHz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P32_User_Manual.pdf\"\u003eUT-P32 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531076859,"sku":"190500300027X","price":860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P32_1_sq.jpg?v=1790709345"},{"product_id":"ut622e-advanced-lcr-meter","title":"UT622E Advanced LCR Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UT622E is the top of the UT622 line: a professional-grade handheld LCR meter that measures to 100 kHz and adds DC resistance (DCR) from 0.01 mΩ to 20 MΩ — so the same instrument characterizes a component's AC behaviour and its DC resistance, which matters for windings, contacts, and low-value parts. It measures L, C, R, Z, ESR, and D\/Q at 0.1% basic accuracy.\u003c\/p\u003e\n\u003cp\u003eWith a 4-wire Kelvin connection, open\/short correction, series\/parallel modelling, and tolerance sorting, the UT622E suits power-electronics design and lab work, on a portable Li-polymer-powered platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdds DC resistance (DCR) measurement: 0.01 mΩ to 20 MΩ\u003c\/li\u003e\n\u003cli\u003eTest frequencies to 100 kHz: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/li\u003e\n\u003cli\u003eMeasures L, C, R, Z, ESR, and D\/Q with 0.1% basic accuracy\u003c\/li\u003e\n\u003cli\u003e4-wire Kelvin connection with open\/short correction\u003c\/li\u003e\n\u003cli\u003eSeries and parallel equivalent-circuit modelling\u003c\/li\u003e\n\u003cli\u003eTolerance sorting from 1% to 20%; up to 20 readings\/s\u003c\/li\u003e\n\u003cli\u003e500-group data logging over USB\u003c\/li\u003e\n\u003cli\u003e2.8-inch TFT display; ~8 h rechargeable Li-polymer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUT622E Details\u003c\/h2\u003e\n\u003ch3\u003eAC and DC Resistance Together\u003c\/h3\u003e\n\u003cp\u003eBeyond the full AC LCR set, the UT622E measures DC resistance from 0.01 mΩ to 20 MΩ. Reading DCR alongside impedance and ESR characterizes windings, contacts, and low-value components more completely than an AC-only meter — a meaningful step for power-electronics work.\u003c\/p\u003e\n\u003ch3\u003e4-Wire Kelvin Measurement\u003c\/h3\u003e\n\u003cp\u003eA 4-wire Kelvin connection separates the drive and sense paths so lead and contact resistance don't corrupt the reading — essential for low-impedance components where milliohm-level errors matter. Open and short correction nulls fixture and lead effects before a measurement run.\u003c\/p\u003e\n\u003ch3\u003eFull Parameter Set\u003c\/h3\u003e\n\u003cp\u003eBeyond L, C, and R, the meter reads impedance (Z), equivalent series resistance (ESR), dissipation factor (D), and quality factor (Q), with series or parallel equivalent-circuit modelling and impedance phase from −179.9° to 179.9° — the parameters needed to characterize a part, not just read its nominal value.\u003c\/p\u003e\n\u003ch3\u003eSorting \u0026amp; Logging\u003c\/h3\u003e\n\u003cp\u003eA tolerance-comparison function sorts parts pass\/fail from 1% to 20% bands at up to 20 measurements per second, suited to incoming inspection and small-batch QC. Results log to 500 groups and transfer over USB.\u003c\/p\u003e\n\u003ch3\u003ePortable Build\u003c\/h3\u003e\n\u003cp\u003eA 2.8-inch color display and a rechargeable Li-polymer pack good for about 8 hours make the UT622E a capable bench and lab instrument that travels.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompare the UT622 Series\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003cth\u003eUT622A\u003c\/th\u003e\n\u003cth\u003eUT622C\u003c\/th\u003e\n\u003cth\u003eUT622E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax test frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kHz\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC resistance (DCR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.01 mΩ – 20 MΩ\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKelvin test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003ePower-electronics component design and verification; characterization needing both AC parameters and DC resistance; lab and R\u0026amp;D measurement; and production QC with tolerance sorting.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat does the UT622E add over the UT622C?\u003c\/h3\u003e\n\u003cp\u003eDC resistance (DCR) measurement from 0.01 mΩ to 20 MΩ, alongside the same 100 kHz AC LCR capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhy measure DCR as well as ESR?\u003c\/h3\u003e\n\u003cp\u003eDCR characterizes windings, contacts, and low-value parts at DC, complementing the AC parameters for a fuller picture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003ch3\u003eWhat is its basic accuracy?\u003c\/h3\u003e\n\u003cp\u003e0.1% basic accuracy across the LCR measurement set.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 pF to 99.999 mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInductance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 µH to 99.999 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 9.9999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESR Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0000 Ω to 999.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MΩ (DCR: 0.01 mΩ to 20.000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD\/Q Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eD: 0.0000 to 9.9999; Q: 0.0000 to 99999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Phase Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-179.9° to 179.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Signal Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Vrms, 0.3 Vrms, 1 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1% to 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalent Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries, Parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Ranging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto LCR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen Short Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Wire Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastest Test Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 times\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320×240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 V 1800 mAh Li-polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 × 192 × 44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20Datasheets\/UT622%20Series%20Data%20Sheet.pdf\"\u003eUT622E Datasheet\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/Meter%20User%20Manuals\/UT622A-C-E_User_Manual.pdf\"\u003eUT622E User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531044091,"sku":"180706280023X","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT622E_1_sq_4c4bec21-3700-4fc0-9fc5-2c857da16ba9.jpg?v=1790709345"},{"product_id":"ut-p33-120-mhz-100-1-1000-1-differential-oscilloscope-probe","title":"UT-P33 120 MHz 100:1\/1000:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e120 MHz differential oscilloscope probe (100:1\/1000:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e120MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 120MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100:1\/1000:1 Attenuation\u003c\/strong\u003e — Divides the input signal for measuring higher-voltage circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14kVpp Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 × 26 × 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100:1, 1000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14kVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MΩ \/ 1 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14kVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5kVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB @ 60 Hz, \u0026gt; 60 dB @ 100 Hz, \u0026gt; 50 dB @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P33_User_Manual.pdf\"\u003eUT-P33 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531109627,"sku":"190500300028X","price":1465.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P33_1_sq.jpg?v=1790709346"},{"product_id":"ut-p40-dc-100-khz-60a-ac-dc-current-probe","title":"UT-P40 DC-100 kHz 60A AC\/DC Current Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100kHz bandwidth, 60A AC\/DC current probe for oscilloscopes. Measures current waveforms non-invasively in power electronics, motor drives, and switch-mode circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Invasive Measurement\u003c\/strong\u003e — Clamp-on design requires no circuit interruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBNC Connection\u003c\/strong\u003e — Standard BNC connector for direct connection to UNI-T oscilloscopes and other oscilloscopes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e231 × 67 × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mV\/A \/ 50 mV\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% ±0.4 A (50 mV\/A range); ±2% ±1 A (5 mV\/A range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P40_User_Manual.pdf\"\u003eUT-P40 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531240699,"sku":"190500300029X","price":452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P40_1_sq.jpg?v=1790709347"},{"product_id":"uts-emi01-near-field-probe-kit","title":"UTS-EMI01 Near-Field Probe Kit","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eNear-field probe set for locating EMI sources on PCBs and cables. Compatible with UNI-T spectrum analyzers.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with UNI-T spectrum analyzers\u003c\/strong\u003e — For use with UNI-T spectrum analyzers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Probe Types\u003c\/strong\u003e — Includes H-field and E-field probes for identifying different EMI source types on PCBs and cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose-Proximity Scanning\u003c\/strong\u003e — Localize interference sources at the component level before running full compliance scans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 MHz - 3 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 × 180 × 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMB male (probe), SMA female (adaptor), N male (to analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFP-3G-P1, NFP-3G-P2, NFP-2G-P3, NFP-3G-P4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UTS-EMI01_DataSheet.pdf\"\u003eUTS-EMI01 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531273467,"sku":"191700100003X","price":450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS-EMI01_sq.jpg?v=1790709346"},{"product_id":"mso5054hd-500-mhz-4ch-12-bit-mixed-signal-oscilloscope","title":"MSO5054HD 500 MHz 4Ch 12-Bit Mixed Signal Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe MSO5054HD is a 500 MHz, 4-channel mixed signal oscilloscope built on UNI-T’s R12™ native 12-bit ADC architecture, with a 5 GSa\/s real-time sample rate (interleave mode), 500 Mpts standard memory depth, and a calculated rise time of ≤0.70 ns. The 12-bit resolution holds at the full 500 MHz bandwidth with no ERES averaging step or sample-rate trade-off, and Ultra Phosphor 3.0 acquisition delivers up to 800,000 wfms\/s standard — 1,500,000 wfms\/s in Sequential Mode. Sixteen digital channels are available with the UT-M15 logic probe pod, on a 10.1-inch capacitive multi-touch display.\u003c\/p\u003e\n\u003cp\u003eFor wide-bandgap power-electronics validation at higher switching frequencies, multi-channel power-supply characterization, and four-channel mixed-signal work on faster MCU and FPGA silicon, the MSO5054HD adds 150 MHz of bandwidth headroom over the family entry while preserving the same native 12-bit ADC, 5 GSa\/s sample rate, and 500 Mpts memory. Calculated rise time falls to ≤0.70 ns — fast enough to capture GaN gate-edge transitions at scale — and the nine-instrument platform stays intact across the upgrade.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz Bandwidth, 4 Channels\u003c\/strong\u003e — 4-channel analog capture with 5 GSa\/s sample rate and 12-bit native vertical resolution, scaling to 16-bit with ERES.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 Mpts Memory Depth\u003c\/strong\u003e — Deep memory for extended captures without sample-rate trade-off; navigation and search across the full memory window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 wfms\/s Standard, 1.5 M in Sequential Mode\u003c\/strong\u003e — Ultra Phosphor 3.0 intensity-graded display with 256 grayscale levels for rare-event hunting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR12™ Native 12-Bit ADC\u003c\/strong\u003e — 4,096 vertical levels at full bandwidth, sixteen times the resolution of a conventional 8-bit oscilloscope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSix Protocols Standard, Nine Optional\u003c\/strong\u003e — RS-232\/UART, I²C, SPI, CAN, LIN included; CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C optional.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 2.5 GHz Spectrum Analyzer\u003c\/strong\u003e — Enhanced FFT up to 4 Mpts, four traces and four detections, waterfall display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional 50 MHz Dual-Channel AWG\u003c\/strong\u003e — Built-in arbitrary waveform generator pairs with the optional Bode plot analyzer for closed-loop frequency-response measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Power Analysis Suite\u003c\/strong\u003e — Switching loss, harmonic analysis, SOA, R\u003csub\u003eDS(on)\u003c\/sub\u003e, modulation, slew rate, ripple analysis, and more.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Digital Channels with UT-M15\u003c\/strong\u003e — Add the UT-M15 logic probe pod for time-correlated mixed-signal debug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Automated Measurements with Histogram and Trend\u003c\/strong\u003e — 27 measurements simultaneously displayed; 39-item single-channel parameter snapshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-Inch Capacitive Touchscreen\u003c\/strong\u003e — 1280×800 HD multi-touch with gesture support; full-SCPI WebServer for browser-based remote control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eR12™ — Native 12-Bit at Full Bandwidth\u003c\/h3\u003e\n\u003cp\u003eR12™ is UNI-T’s native 12-bit ADC architecture: 4,096 vertical quantization levels — sixteen times the resolution of a conventional 8-bit oscilloscope — held at the full 500 MHz bandwidth and 5 GSa\/s sample rate, with no ERES averaging step and no sample-rate trade-off to get there. ERES (enhanced resolution) extends effective vertical resolution up to 16-bit when bandwidth headroom is available, but the baseline 12-bit performance is the front-end’s native characteristic, not a software boost. For low-amplitude signal work — switching ripple riding on a busy DC rail, sensor-bridge outputs into a noisy ADC, jitter analysis on a clock line — the difference between 8-bit quantization steps showing through the measurement and 12-bit fidelity disappearing them is the difference between a usable capture and a noisy one.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_ERES.png\" alt=\"R12 native 12-bit ADC at full bandwidth\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eR12™ native 12-bit ADC: 4,096 quantization levels, no ERES required.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 3.0 — 800,000 wfms\/s, 1.5 M in Sequential Mode\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 3.0 is UNI-T’s third-generation waveform-mapping architecture, combining parallel FPGA acquisition with 256-level grayscale intensity grading. Standard waveform capture rate is up to 800,000 wfms\/s — high enough to surface intermittent timing anomalies on a long capture window without missing them between screen redraws. In Sequential Mode — the segmented-memory acquisition mode that conditions captures on a trigger event — capture rate climbs to 1,500,000 wfms\/s, and the scope holds up to 400,000 frames of uninterrupted hardware real-time recording for post-capture replay and analysis. Rare-event hunting on a live system stops being a watch-and-wait exercise and starts being an analysis-after-capture exercise.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_UltraPhosphor3c.png\" alt=\"Ultra Phosphor 3.0 with 256 grayscale levels\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUltra Phosphor 3.0: up to 800,000 wfms\/s standard, 1,500,000 wfms\/s in Sequential Mode.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eNine Instruments in One — The HD Workhorse Platform\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD platform integrates nine instrument functions into one bench unit: digital storage oscilloscope, 16-channel logic analyzer (with the optional UT-M15 probe pod), 50 MHz dual-channel function and arbitrary waveform generator (optional), 2.5 GHz spectrum analyzer, 4-digit digital voltmeter, 7-digit hardware frequency counter, multi-protocol serial-bus analyzer, Bode plot analyzer (optional, paired with the AWG for closed-loop sweep), and power-electronics analyzer (optional). For small-lab consolidation and education-track lab benches, the integration replaces three to five separate instruments with one instrument footprint, one calibration chain, and one operator-training surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/mso5000hd_9-in-1.png\" alt=\"Nine integrated instruments in one MSO5000HD\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNine instruments integrated: scope, logic analyzer, spectrum analyzer, AWG, DVM, frequency counter, protocol analyzer, Bode plot, power analyzer.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eDeep Memory — 500 Mpts\u003c\/h3\u003e\n\u003cp\u003e500 Mpts of acquisition memory standard, with adjustable depths from Auto (5 Mpts) through 25 kpts, 250 kpts, 500 kpts, 5 Mpts, 50 Mpts, 100 Mpts, and 500 Mpts. Deep memory matters when the acquisition window is long — minutes-long captures looking for an intermittent fault, multi-frame protocol traces across a power-on sequence, or extended ripple analysis across a load-step transient — because the sample rate stays at 5 GSa\/s for far longer than a shallow-memory scope before forcing a sample-rate trade-off. Combined with the navigation-and-search function (event, time, and marker navigation modes), the deep memory is searchable: zoom into a specific glitch in a 500 Mpt capture without scrolling through the rest.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e16 Digital Channels with the UT-M15 Probe Pod (Optional)\u003c\/h3\u003e\n\u003cp\u003eMixed-signal capability is hardware-standard in the MSO5000HD chassis — the 16-digital-channel logic-analyzer front end is built in. Adding the digital channels requires the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit connections and connects directly to 8×2 square pins (2.54 mm) for fast attachment to development boards. Maximum digital sample rate is 1.25 GSa\/s with a minimum detectable pulse width of 800 ps, and threshold selection covers TTL, 5.0 V\/3.3 V\/2.5 V\/1.8 V CMOS, ECL, PECL, LVDS, and a custom level — covering essentially every common digital interface voltage on modern hardware. Digital and analog channels share the same time base, the same trigger system, and the same display, so a falling SPI clock edge and the analog-domain crosstalk it causes show up in the same frame.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Protocol Decoders — 6 Standard, 9 Optional\u003c\/h3\u003e\n\u003cp\u003eSix protocols decode standard with the MSO5000HD: RS-232\/422\/485\/UART, I²C, SPI, CAN, and LIN. Nine additional protocols are available as separately licensed options: CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C. The decoder runs on dedicated decode hardware, not a software post-processing path, so decode results display in real time during acquisition rather than after-the-fact on saved data — the difference between “debug a protocol stack interactively” and “capture, save, transfer, open in a separate tool, decode.” Trigger-and-decode operates pause-and-record modes for both interactive bring-up and unattended logging, and the event list plus search function lets you jump to a specific framed event across a 500 Mpt capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_Protocols.png\" alt=\"MSO5000HD protocol decoding library\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15 protocol decoders with hardware-accelerated decode and event search.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Spectrum Analyzer — 4 Mpts FFT to 2.5 GHz\u003c\/h3\u003e\n\u003cp\u003eThe MSO5000HD’s built-in spectrum analyzer leverages the 5 GSa\/s sample rate for a 0–2.5 GHz frequency range — useful for characterizing wideband signals, identifying spurious emissions, and verifying clock harmonics at frequencies beyond what 2.5 GSa\/s instruments can analyze. Enhanced FFT supports up to 4 Mpts with 4-channel parallel signal analysis, four traces and four detections, auto\/manual\/threshold marker types, marker point lists, and a waterfall-curve display mode for time-evolving spectra. For pre-compliance EMI screening, switching-supply noise hunting, and clock-quality verification, the integrated spectrum analyzer means one instrument covers both time-domain and frequency-domain measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_spectrum_analyzer.png\" alt=\"MSO5000HD built-in spectrum analyzer\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in spectrum analyzer: enhanced FFT up to 4 Mpts, 0–2.5 GHz frequency range.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePower Analysis — Optional Multi-Class Suite\u003c\/h3\u003e\n\u003cp\u003eThe optional power-analysis package adds nine classes of power-electronics measurement to the MSO5000HD: power quality, surge current, safe operating area (SOA), harmonic analysis, R\u003csub\u003eDS(on)\u003c\/sub\u003e measurement, modulation analysis, switching-loss analysis, slew rate, and ripple analysis — with transient-response and power-efficiency measurements added in firmware updates. For early-stage power-converter design, the package replaces a separate power-analyzer instrument: the same scope that captures the gate-drive waveform calculates the switching loss across the cycle, and the same FFT mode that screens for spurs computes the harmonic spectrum on the AC input. Connect a voltage probe and a current probe, select the analysis type, and the calculations run on-instrument — no post-processing workflow, no separate software tool.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_power.png\" alt=\"MSO5000HD power analysis suite\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eOptional power-analysis suite: switching loss, harmonic analysis, ripple, slew rate, modulation, safe operating area, transient response, power efficiency, turn on\/off.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003e56 Automated Measurements with Histogram and Trend Statistics\u003c\/h3\u003e\n\u003cp\u003e56 automated measurement types cover voltage, time, frequency-domain, and area-under-curve calculations — with up to 27 measurements displayed simultaneously on screen and a 39-item single-channel parameter snapshot for production-style documentation. Histogram and trend-line displays show measurement statistics over time, useful for signal-integrity work where the parameter distribution matters as much as a single instantaneous value. The new top-and-bottom amplitude calculation strategy and the burst-region measurement function add capability for non-stationary signals where the measurement window has to be localized to a specific event rather than averaged across the full capture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/MSO5000HD_56_types.png\" alt=\"56 automated measurement types\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e56 measurement types with histogram and trend-line statistics, up to 27 simultaneous on-screen.\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eTiming Analyzer — Bus Timing Conformance Testing\u003c\/h3\u003e\n\u003cp\u003eThe timing analyzer function performs conformance-grade timing measurements on serial bus signals: pulse width, amplitude, edge characteristics, setup time, and hold time on I²C, SPI, CAN, and I²S buses. For consumer-electronics manufacturing — mobile phones, smart wearables, home appliances, multimedia audio-video equipment, and automotive electronics — bus-timing consistency is the difference between a board that passes audit and one that fails customer qualification. The MSO5000HD generates exportable conformance test reports, turning the scope into a documentation tool for design verification and test-lab compliance work.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e10.1-Inch Touch UI, WebServer, and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eA 10.1-inch 1280×800 capacitive multi-touch display anchors the front-panel experience — touch, drag, pinch-to-zoom, and rectangle-drawing gestures for common waveform operations — while preserving the traditional knob-and-key controls that bench engineers want for fine adjustment. Mouse and keyboard are supported as additional input methods. For automation, the built-in WebServer provides browser-based instrument control over the network — SCPI commands, waveform export, and online user-manual access — from PC or mobile devices, and full SCPI compliance over LAN or USB Device enables programmatic control from LabVIEW, Python, or any SCPI-aware test framework. UNI-T’s free instrument manager runs on the PC side for graphical control without writing custom automation code.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eR\u0026amp;D and Embedded Validation\u003c\/h3\u003e\n\u003cp\u003eFor R\u0026amp;D validation at the 500 MHz bandwidth tier, the MSO5054HD delivers fast-edge capture and four-channel timing-correlated analog plus digital views (with the UT-M15 logic probe pod) on faster ARM and RISC-V silicon, PCIe Gen2 reference clocks, and high-speed serial peripherals where 350 MHz starts to limit visibility into rise-time and overshoot detail.\u003c\/p\u003e\n\u003ch3\u003ePower Electronics Design and Validation\u003c\/h3\u003e\n\u003cp\u003eFor GaN\/SiC power-stage validation, the 500 MHz bandwidth and ≤0.70 ns rise time capture switching-edge detail at frequencies where slower scopes start to round corners — useful for switching-loss measurement, EMI root-cause work, and gate-driver characterization on dense converter boards.\u003c\/p\u003e\n\u003ch3\u003eTest Laboratory and Consultancy Work\u003c\/h3\u003e\n\u003cp\u003eFor external test-lab work characterizing customer-supplied DUTs across mixed power and signal-integrity scopes, the MSO5054HD’s 12-bit acquisition plus 2.5 GHz spectrum analyzer plus optional Bode plot bring three classes of measurement under one instrument cover for compact bench setups.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded in Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eProbe set: passive 10:1 voltage probes (4×) sized for the bandwidth of the analog front end\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Add-Ons\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUT-M15 Logic Probe Pod — adds 16 digital channels with high\/low 8-bit connectors and direct 8×2 square-pin attachment.\u003c\/li\u003e\n\u003cli\u003eActive probes — for 50 Ω high-bandwidth signal-integrity work where a passive 10x probe limits visibility.\u003c\/li\u003e\n\u003cli\u003eCurrent probe(s) — for power-electronics work paired with the optional power-analysis suite; voltage and current probe simultaneously for switching-loss measurement.\u003c\/li\u003e\n\u003cli\u003eAWG license — activates the dual-channel 50 MHz arbitrary waveform generator hardware in the chassis.\u003c\/li\u003e\n\u003cli\u003eBode plot license — pairs with the AWG for closed-loop frequency-response sweep on amplifiers, filters, and power-supply control loops.\u003c\/li\u003e\n\u003cli\u003ePower analysis license — activates the multi-class power-electronics measurement suite.\u003c\/li\u003e\n\u003cli\u003eProtocol decoder licenses — CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C, available individually.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat protocols are included with the MSO5000HD as standard?\u003c\/p\u003e\n\u003cp\u003eRS-232\/422\/485, UART, I²C, SPI, CAN, and LIN are decoded standard with no additional license required. CAN-FD, CAN-XL, FlexRay, SENT, Audio (I²S\/LJ\/RJ\/TDM), MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, and I3C are available as separately licensed options — activated on the same instrument with no firmware upgrade or reflash required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the practical advantage of 12-bit native resolution over 8-bit?\u003c\/p\u003e\n\u003cp\u003eA 12-bit ADC provides 4,096 vertical quantization levels compared to 256 for an 8-bit scope — sixteen times the resolution. In low-amplitude work (switching ripple riding on a DC rail, sensor outputs from a strain gauge, jitter on a clock line, or any signal where the amplitude of interest is much smaller than the channel’s full-scale range), 8-bit quantization steps show up as visible stair-stepping in the captured waveform. 12-bit acquisition keeps those steps below the front-end’s noise floor, so what you’re looking at on screen is the signal, not the digitization grid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eHow do I add 16 digital channels for mixed-signal work?\u003c\/p\u003e\n\u003cp\u003eThe 16-digital-channel logic-analyzer front end is built into every MSO5000HD chassis as hardware-standard. To use it, add the optional UT-M15 logic probe pod, which provides separate high 8-bit and low 8-bit pin connections and attaches directly to standard 2.54 mm 8×2 square-pin headers on development boards. Maximum digital sample rate is 1.25 GSa\/s with an 800 ps minimum detectable pulse width.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between Ultra Phosphor 3.0’s 800,000 wfms\/s standard rate and the 1,500,000 wfms\/s sequential-mode rate?\u003c\/p\u003e\n\u003cp\u003eThe 800,000 wfms\/s rate is the continuous waveform-capture rate during normal acquisition — the rate at which the scope acquires, processes, and displays new waveforms back-to-back during live operation. The 1,500,000 wfms\/s sequential-mode rate applies in segmented-memory acquisition where the scope captures only a short window around each trigger event, then re-arms quickly for the next trigger; this maximizes capture density when chasing intermittent events at the cost of dead time between captures. In practical terms: continuous 800K for general-purpose acquisition, sequential 1.5M for rare-event hunting on a triggered signal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the AWG (arbitrary waveform generator) included or optional?\u003c\/p\u003e\n\u003cp\u003eThe AWG hardware is built into every MSO5000HD chassis as hardware-standard, but activation requires the AWG software license. Once activated, it provides dual-channel 50 MHz output with sine, square, pulse, ramp, arbitrary, noise, and DC waveforms; AM, FM, ASK, FSK, and sweep modulation; and the ability to load on-screen captured waveforms back to the Gen output for replay-style stimulus testing. The optional Bode plot analyzer pairs with the AWG for closed-loop frequency-response measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I control the MSO5000HD remotely without installing local software?\u003c\/p\u003e\n\u003cp\u003eYes. The built-in WebServer provides full instrument control through any standard web browser on a PC, tablet, or mobile device on the same network — no client install, no driver download. Common operations (waveform capture, screenshot, parameter readback, settings changes, file export) work directly through the browser. For programmatic control, the same interface accepts SCPI commands over LAN or USB, compatible with LabVIEW, Python, MATLAB, and any SCPI-aware automation framework. UNI-T also provides a free instrument-manager application for users who prefer a graphical desktop client.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003ePart of the MSO5000HD oscilloscope series. See the series page to compare bandwidth and channel options across the lineup, or explore the broader UNI-T oscilloscope catalog.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (50 Ω, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Bandwidth (1 MΩ, −3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Analog + 16 Digital (with optional UT-M15 probe pod)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GSa\/s (interleave mode) \/ 2.5 GSa\/s (non-interleave mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Channel Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit native (up to 16-bit with ERES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Mpts maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800,000 wfms\/s standard; 1,500,000 wfms\/s in Sequential Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time (10–90%, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.70 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackground Noise (full BW, Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 µVrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitive multi-touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequential Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 400,000 frames; minimum two trigger intervals \u0026lt; 700 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Real-Time Waveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 types: edge, pulse width, video, ramp, runt, over-amplitude, delay, timeout, duration, setup \u0026amp; hold, Nth edge, code pattern; Zone trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Triggering and Decoding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 protocols total. \u003cstrong\u003eStandard:\u003c\/strong\u003e RS-232\/422\/485\/UART, I²C, SPI, CAN, LIN. \u003cstrong\u003eOptional:\u003c\/strong\u003e CAN-FD, CAN-XL, FlexRay, SENT, Audio, MIL-STD-1553B, ARINC 429, Manchester, 1-Wire, I3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectrum Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–2.5 GHz, enhanced FFT up to 4 Mpts, 4-channel parallel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz equivalent, dual-channel, 312.5 MSa\/s, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBode Plot Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — frequency response, loop stability, filter, amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Analyzer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional — switching loss, harmonics, ripple, slew rate, R\u003csub\u003eDS(on)\u003c\/sub\u003e, SOA, modulation, transient response, power efficiency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 types; up to 27 simultaneous; histogram and trend display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC\u003csub\u003eVpk\u003c\/sub\u003e); 135 V\u003csub\u003eRMS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V\u003csub\u003eRMS\u003c\/sub\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host\/Device, LAN, EXT Trig, AUX Out (Trig Out \/ Pass-Fail \/ DVM), Gen Out, HDMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI over LAN\/USB; built-in WebServer (browser, PC + mobile); UNI-T Instrument Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=108\"\u003eMSO5054HD Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB3.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMSO5000HD-1WIRE — 1-Wire Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-ARINC429 — Aerospace ARINC429 Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUDIO — Audio Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AUTO — Automotive Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-AWG — 50 MHz 2Ch Arbitrary Waveform Generator with Bode Plot\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BND — Complete Serial Analysis Bundle\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BW3M5T1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-BW5MT1G — 1GHz bandwidth upgrade\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANFD — Automotive CAN-FD Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-CANXL — Automotive CAN-XL Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-FLEX — Automotive FlexRay Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-I3C — Embedded Systems I3C Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MANCH — Manchester Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-MIL1553 — MIL-STD-1553 Serial Bus Trigger and Analysis Option\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-PWR — Advanced Power Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-SENT — Automotive SENT Serial Bus Trigger and Analysis\u003c\/li\u003e\n  \u003cli\u003eMSO5000HD-TIMING — Advanced Timing Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531306235,"sku":"181100300115X","price":3994.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/MSO5000HD-1_908fb389-fc67-4ebb-ad3a-a1aa4b16c785.png?v=1790709347"},{"product_id":"upo1104-100-mhz-4ch-digital-storage-oscilloscope","title":"UPO1104 100 MHz 4Ch Digital Storage Oscilloscope","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UPO1104\u003c\/strong\u003e is a 100 MHz, four-channel digital storage oscilloscope with 2 GSa\/s real-time sample rate, 56 Mpts memory depth, and a 500,000 wfms\/s waveform capture rate (Fast Acquire mode). Ultra Phosphor 2.0 display technology drives 256-level intensity grading on a 7-inch WVGA TFT LCD, making it straightforward to distinguish frequent signal behavior from rare anomalies at a glance.\u003c\/p\u003e\n\u003cp\u003eFour channels, 56 Mpts of memory, an independent DVM module, an enhanced 1 Mpts FFT, and three serial bus protocols decoded as standard — features that typically migrate to mid-tier scopes. The UPO1104 keeps them on the value-tier bench, which is the value proposition for teaching labs running twenty stations and engineering teams sourcing a second scope without sacrificing capability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 MHz bandwidth, 4 channels\u003c\/strong\u003e — 2 GSa\/s real-time sample rate (2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four), ≤ 3.5 ns calculated rise time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e56 Mpts memory depth\u003c\/strong\u003e — capture full switching cycles and long protocol sequences without trading sample rate for record length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e500,000 wfms\/s waveform capture rate\u003c\/strong\u003e — Ultra Phosphor 2.0 with 256-level intensity grading, in Fast Acquire mode. Fast enough to surface intermittent events that slower scopes spend hours missing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Mpts enhanced FFT\u003c\/strong\u003e — frequency-domain analysis with frequency setting, demodulation mode, waterfall display, and marker measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent DVM module\u003c\/strong\u003e — dedicated AC\/DC True RMS digital voltmeter, operating in parallel with scope acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-digit hardware frequency counter\u003c\/strong\u003e — hardware-accelerated counter alongside the scope channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 serial bus decoders standard\u003c\/strong\u003e — RS-232\/UART, I²C, and SPI trigger and decode included; full-memory hardware decoding turns multi-second decode times into milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 automated measurements\u003c\/strong\u003e — time, voltage, frequency, and statistical measurements with cursor-area scoping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple trigger types\u003c\/strong\u003e — edge, pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb remote control\u003c\/strong\u003e — browser-based access from any PC or mobile device on the LAN; no driver software, no host application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCPI + LAN automation\u003c\/strong\u003e — Standard Command for Programmable Instruments over LAN for scripted test sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UPO1104 Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUltra Phosphor 2.0\u003c\/h3\u003e\n\u003cp\u003eUltra Phosphor 2.0 is UNI-T's intensity-graded display technology. Waveforms paint with 256-level brightness, where signals that recur often appear bright and rare anomalies show as faint streaks against the baseline trace — the kind of detail a flat-color display paints over.\u003c\/p\u003e\n\u003cp\u003eStandard sampling reaches 150,000 wfms\/s; engaging Fast Acquire mode pushes the rate to 500,000 wfms\/s. Combined with hardware-accelerated continuous waveform recording at up to 120,000 frames, the scope catches glitches, runt pulses, and other transient events that 8-bit value-tier oscilloscopes typically don't surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_waveform_capture.png\" alt=\"UNI-T UPO1104 Ultra Phosphor 2.0 Waveform Capture\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1104 Ultra Phosphor 2.0 Waveform Capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_waveform_capture.png\" alt=\"UNI-T UPO1104 Ultra Phosphor 2.0 Waveform Capture\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1104 Ultra Phosphor 2.0 Waveform Capture\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eIndependent DVM Module\u003c\/h3\u003e\n\u003cp\u003eThe UPO1104 includes a built-in 4-bit digital voltmeter that operates in parallel with the scope channels, displaying AC\/DC True RMS values continuously while the oscilloscope captures waveforms. The DVM has its own display readout and a configurable warning when measurements exceed the specified range — a separate instrument's worth of capability without a separate instrument's bench space, useful for steady-state DC monitoring alongside dynamic AC measurement and for double-checking power-supply rails without breaking the trigger setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e1 Mpts Enhanced FFT\u003c\/h3\u003e\n\u003cp\u003eThe 1 Mpts FFT converts time-domain waveforms to the frequency domain at resolution that matches mid-tier oscilloscopes. Frequency setting, demodulation mode, waterfall display, and automatic peak marking are all standard, supporting EMI troubleshooting, switching-supply harmonic characterization, audio-band analysis, and clock-spur identification. Five window functions (Rectangle, Hanning, Blackman, Hamming, FlatTop) cover the common analysis trade-offs between frequency resolution and amplitude accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_fft.png\" alt=\"UNI-T UPO1104 1 Mpts Enhanced FFT View\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1104 1 Mpts Enhanced FFT View\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/upo1000_fft.png\" alt=\"UNI-T UPO1104 1 Mpts Enhanced FFT View\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1104 1 Mpts Enhanced FFT View\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eStandard Bus Decoding — RS-232\/UART, I²C, SPI\u003c\/h3\u003e\n\u003cp\u003eRS-232\/UART, I²C, and SPI trigger and decode are standard — no protocol licenses, no add-on packages. Decoded bus traffic overlays the waveform with field-level annotation, and the event list view shows decoded packets alongside the time stamps. Hardware decoding running across the full 56 Mpts memory turns what would be a tens-of-seconds software decode into a sub-second operation, making the UPO1000 a usable embedded-debug instrument rather than a strictly time-domain scope.\u003c\/p\u003e\n\u003cp\u003eNo optional protocol licenses are available on the UPO1104: CAN, CAN-FD, LIN, and FlexRay are not supported on this platform. Buyers who need automotive bus decoding should look at the UPO1000HD or MSO\/UPO2000 series, which support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e7-digit Hardware Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eA 7-digit hardware-accelerated counter runs alongside the scope's standard automated measurements. The counter reads independently from the channel measurement engine, which gives stable, high-resolution frequency readings on stable signals without the jitter that software counters can exhibit on the lower-density end of the rate range. Useful for verifying oscillator frequencies, clock-recovery loops, and PWM duty cycles where a stable frequency number matters more than time-domain detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eMultiple Trigger Types\u003c\/h3\u003e\n\u003cp\u003eBeyond standard edge triggering, the scope offers pulse width, video, slope, runt, over-amplitude, delay, timeout, duration, setup\/hold, Nth edge, and pattern triggers. Runt and over-amplitude triggers isolate signal-integrity violations that an edge-only trigger would never catch; setup\/hold and Nth edge triggers isolate specific cycles in long protocol captures. The full set is standard, with no trigger-package upgrades to license.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e36 Automated Measurements with Cursor-Area Scoping\u003c\/h3\u003e\n\u003cp\u003eThirty-six automated measurement parameters cover time, voltage, frequency, and statistical categories: rise\/fall time, pulse width, duty cycle, frequency, period, amplitude, RMS, peak-peak, mean, standard deviation, and others. Each measurement supports cursor-area scoping — the measurement runs only within the cursor window rather than across the full record — useful for measuring a specific burst within a long capture without rezooming. Statistics (min, max, mean, std-dev) accumulate over time for characterization of measurement drift.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UPO1000_cursor_area.png\" alt=\"UNI-T UPO1104 Cursor-Area Measurement Mode\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UPO1104 Cursor-Area Measurement Mode\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/UNI-T\/image\/upload\/UPO1000_cursor_area.png\" alt=\"UNI-T UPO1104 Cursor-Area Measurement Mode\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UPO1104 Cursor-Area Measurement Mode\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eWeb Remote Control and SCPI Automation\u003c\/h3\u003e\n\u003cp\u003eConnect the UPO1104 to the LAN and access the full instrument from any web browser — PC, Mac, or mobile — with no driver installation, no host application, no setup. Capture screenshots, change settings, transfer waveform data, and run SCPI commands from any device on the network. Useful for shared lab instruments, rack-mounted teaching benches with cable runs across the room, and Python or LabVIEW automation scripts that drive the scope through standard SCPI over LAN.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eConnectivity (USB, LAN, AUX)\u003c\/h3\u003e\n\u003cp\u003eStandard interfaces include USB-Host (front and rear) for thumb-drive screenshot capture and firmware updates, USB-Device (rear) for SCPI over USB to a PC, Gigabit LAN for SCPI and web remote, and AUX output for triggered signal handoff. RS-232 is not present on this platform; SCPI runs over USB and LAN. The LAN connection supports both DHCP and static IP configuration for fixed-IP rack deployments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eTeaching Lab and Trade-School Curriculum (Education)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-station deployment at value-tier prices: a real 4 channels scope on every bench, with the same Ultra Phosphor 2.0 UI that students will see in industry on the UPO1000HD and MSO1000HD families.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory and 1 Mpts FFT cover the full spectrum-and-time-domain undergraduate curriculum without the memory-vs-sample-rate trade-offs that entry scopes normally impose.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics let students focus on circuit behavior rather than measurement methodology, while the cursor-area mode supports manual measurement teaching.\u003c\/li\u003e\n\u003cli\u003eWeb-based remote control mirrors the screen for classroom demonstration without USB capture cables or projector adapters; SCPI over LAN supports Python and LabVIEW lab exercises.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eEmbedded Systems Development (R\u0026amp;D)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThree serial bus decoders standard (RS-232\/UART, I²C, SPI) cover most low-speed embedded debug workflows without protocol-license fees.\u003c\/li\u003e\n\u003cli\u003e56 Mpts memory captures full firmware-boot and protocol sequences in a single trigger, with full-memory hardware decoding for sub-second decode of long captures.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module reads supply rails alongside scope traces — useful for verifying brownout, monitoring switching ripple, or validating reference-voltage stability during prototype bring-up.\u003c\/li\u003e\n\u003cli\u003eSCPI over LAN runs Python regression scripts on the same instrument that the bench engineer uses interactively — automation without a separate automation-class scope.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronics Service, Repair, and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBench-portable form factor: AC-line bench scope sized for the typical service workshop without the depth or weight of a flagship instrument.\u003c\/li\u003e\n\u003cli\u003eUltra Phosphor 2.0 with 256-level intensity grading reveals signal-integrity violations (runt pulses, glitches) that flat-color displays paint over — the difference between fixing the root cause and replacing the symptom.\u003c\/li\u003e\n\u003cli\u003eHardware frequency counter gives stable rate readings for verifying oscillator and clock-recovery behavior during board-level repair.\u003c\/li\u003e\n\u003cli\u003eAC\/DC True RMS DVM module replaces the bench multimeter for steady-state checks while keeping the scope trigger configuration intact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSwitching-Mode Power Supply Validation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBandwidth selection from 100 MHz matches the switching frequency range of most commercial switching-mode designs at 100 kHz to several MHz, with 56 Mpts memory for capturing long startup transients without losing sample rate.\u003c\/li\u003e\n\u003cli\u003e1 Mpts FFT characterizes ripple harmonics and switching-noise spectral content for EMI pre-compliance investigation alongside time-domain switching analysis.\u003c\/li\u003e\n\u003cli\u003eMultiple trigger types (runt, over-amplitude, pulse-width) isolate switching faults, current spikes during startup, and protection-circuit activations.\u003c\/li\u003e\n\u003cli\u003eIndependent DVM module monitors output-rail DC value while scope captures dynamic AC load-step behavior — both halves of the supply characterization on one instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Test and Quality Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSCPI over LAN supports rack-mounted production-line deployment with Python or LabVIEW test scripts; the web remote interface gives line operators a familiar browser-based view without driver installation on each test station.\u003c\/li\u003e\n\u003cli\u003e36 automated measurements with statistics support go\/no-go testing of board-level signal-integrity specs; the cursor-area mode isolates specific cycles for measurement without re-zooming the full capture.\u003c\/li\u003e\n\u003cli\u003eContinuous waveform recording into the memory depth supports historical archiving of production-line captures for later analysis when a batch shows yield-tail issues.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eEMI Pre-Compliance Investigation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Mpts FFT with five window functions, demodulation mode, and waterfall display supports time-correlated EMI investigation against the time-domain switching waveform — useful for tracking down which switching event produces which emission peak.\u003c\/li\u003e\n\u003cli\u003eMarker measurement on the FFT supports quick peak frequency and amplitude readout during emission-hunt work on a prototype board.\u003c\/li\u003e\n\u003cli\u003eCombined with a near-field probe set and a Faraday-cage cardboard tent, the FFT view supports pre-compliance investigation that catches the obvious failures before the expensive compliance-lab booking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPO1104 digital storage oscilloscope\u003c\/li\u003e\n\u003cli\u003ePower cord (national standard)\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 data cable\u003c\/li\u003e\n\u003cli\u003e4 × passive probes — UT-P04 (100 MHz, one per channel)\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003cli\u003eFactory calibration certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-bandwidth passive probes\u003c\/strong\u003e — UT-P07A (500 MHz) for buyers anticipating a step-up scope in the future.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-voltage passive probes\u003c\/strong\u003e — UT-P20 (100:1, 250 MHz), UT-V23 (100:1), UT-P21 (1000:1, DC 10 kV \/ AC 7 kVrms) for line-voltage and HV switching work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential probes\u003c\/strong\u003e — UT-P30, UT-P31, UT-P32, UT-P33, UT-P35, UT-P36 for floating measurements where ground reference can't be tied to scope chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent probes\u003c\/strong\u003e — UT-P40, UT-P41, UT-P42, UT-P43, UT-P44; UT-P4150 for high-current AC\/DC measurement on switching and motor-drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation transformer\u003c\/strong\u003e — UT-ISOT for line-powered DUTs that require galvanic isolation between scope ground and DUT ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO1054 — 50 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPO1104\u003c\/strong\u003e — 100 MHz, 4 channels, 2 GSa\/s \u003cem\u003e(this product)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003e\nUPO1204 — 200 MHz, 4 channels, 2 GSa\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStep Up — UPO1000HD (4-channel, 12-Bit Vertical)\u003c\/h3\u003e\n\u003cp\u003eIf your application needs higher vertical resolution or deeper memory than the UPO1104 provides, the UPO1000HD family offers 12-bit vertical resolution and the same Ultra Phosphor 2.0 display engine in the same cabinet footprint.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nUPO1084HD — 80 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003cli\u003e\nUPO1154HD — 150 MHz, 4 channels, 12-bit vertical resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich serial bus protocols are decoded as standard, and which require a license?\u003c\/p\u003e\n\u003cp\u003eThe UPO1104 decodes \u003cstrong\u003eRS-232\/UART, I²C, and SPI\u003c\/strong\u003e as standard — trigger and decode functions for all three are included with the scope, with no license fees and no protocol-option purchase required. \u003cstrong\u003eNo optional protocol decoders are available on this platform.\u003c\/strong\u003e CAN, CAN-FD, LIN, and FlexRay are not supported on the UPO1000 platform. If your application requires automotive bus decoding, the UPO1000HD or MSO\/UPO2000 series support those protocols as paid options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is Fast Acquire mode, and when should I use it?\u003c\/p\u003e\n\u003cp\u003eFast Acquire is a UPO1000-series acquisition mode that boosts waveform capture rate from 150,000 wfms\/s (standard) to \u003cstrong\u003e500,000 wfms\/s\u003c\/strong\u003e. The trade-off is that some screen-update detail is sacrificed for raw capture throughput. Use Fast Acquire when hunting intermittent signal-integrity events (glitches, runt pulses, rare protocol violations) that depend on capturing many waveforms quickly. Use standard mode for everyday time-domain measurement work where the display refresh rate matters more than raw capture density.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the DVM module share input channels with the scope, or is it truly independent?\u003c\/p\u003e\n\u003cp\u003eThe DVM is \u003cstrong\u003etruly independent\u003c\/strong\u003e: it has its own 4-bit measurement input and operates in parallel with the four (or two) scope channels. You can run a continuous AC\/DC True RMS reading on a supply rail while the scope captures dynamic switching behavior on another channel, without any time-sharing between the two functions. The DVM readout appears on a dedicated portion of the screen and persists across scope-channel configuration changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does the web remote control look like in practice, and how does SCPI automation work?\u003c\/p\u003e\n\u003cp\u003eConnect the UPO1104 to your LAN, point any browser at the scope's IP, and you get a full-screen replica of the front panel that you can drive from your desk or a mobile device — no driver installation, no host application. Useful for shared lab instruments and projection during teaching demos. For automation, the scope responds to \u003cstrong\u003eSCPI commands over LAN\u003c\/strong\u003e (Standard Commands for Programmable Instruments), which means Python (pyvisa), MATLAB Instrument Control Toolbox, LabVIEW, and any other VISA-aware tool can drive the scope through scripts. SCPI also runs over USB-Device for PC-tethered automation when LAN isn't available.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Sample Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Rate per Channel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GSa\/s on a single channel; 1 GSa\/s on two; 500 MSa\/s on all four\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalculated Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 3.5 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 Mpts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical Scale (1 MΩ)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 µV\/div to 20 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V (DC + AC Vpk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Capture Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 wfms\/s (Fast Acquire mode); 150,000 wfms\/s normal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Frame Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120,000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFFT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Mpts enhanced FFT (5 window functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDVM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent module — 4-bit, AC\/DC True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-digit hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomated Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36 parameters with statistics and cursor-area scoping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEdge, Pulse Width, Video, Slope, Runt, Over-Amplitude, Delay, Timeout, Duration, Setup\/Hold, Nth Edge, Pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Bus Decoding (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232\/UART, I²C, SPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Protocol Decoders\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone available on this platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-inch WVGA TFT LCD, 256-level intensity grading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Host (front + rear), USB-Device (rear), LAN (1 GbE), AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeb browser (no driver), SCPI over LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e306 × 138 × 107 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=75\"\u003eUPO1104 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531339003,"sku":"181100200076X","price":407.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UPO1104_Probes.jpg?v=1790709347"},{"product_id":"ut-p36-100-mhz-200-1-2000-1-differential-oscilloscope-probe","title":"UT-P36 100 MHz 200:1\/2000:1 Differential Oscilloscope Probe","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003e100 MHz differential oscilloscope probe (200:1\/2000:1 attenuation) for safely measuring floating voltages across motor drives, power converters, and bridge circuits. Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100MHz Bandwidth\u003c\/strong\u003e — Captures signal content up to 100MHz for accurate waveform measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200:1\/2000:1 Attenuation\u003c\/strong\u003e — Attenuation ratio suited to the probe measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e560VDC+PeakAC \/ 5600VDC+Peak AC, Accuracy: 2% Maximum Input Voltage\u003c\/strong\u003e — Rated input voltage for safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard BNC Connection\u003c\/strong\u003e — Compatible with UNI-T oscilloscopes and most oscilloscopes with BNC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCAT Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT I 2800 V \/ CAT II 1400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200:1, 2000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Max Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30cm input \/ 90cm output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 1.5mVrms (1\/200); ≤ 1mVrms (1\/2000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDifferential Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5600Vpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2800Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dB DC, ≥ 60 dB 100 Hz, ≥ 50 dB 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/storage.googleapis.com\/uni-tdocuments\/UT-P35_UT-P36_User_Manual.pdf\"\u003eUT-P36 User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531371771,"sku":"190500100122X","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UT-P36_1_sq.jpg?v=1790709347"},{"product_id":"udp3303c-3ch-195w-30v-3a-programmable-linear-dc-power-supply","title":"UDP3303C 3Ch 195W 30V\/3A Programmable Linear DC Power Supply","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UDP3303C is the SCPI-programmable counterpart to the UDP3303A — same 195W three-channel linear hardware, same CH3 logic-rail selector cycling 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A, same ≤1 mVrms ripple — with a back-panel USB-Device port and RS-232 added for full SCPI control. CH1 and CH2 deliver 0–30V at 0–3A; series and parallel modes extend that to 60V or 6A.\u003c\/p\u003e\n  \u003cp\u003eProgramming accuracy holds inside ≤0.1% + 30 mV on voltage and ≤0.5% + 2 mA on current — fine enough for sleep-mode current characterization on IoT prototypes, battery-charge cut-off testing, and any automated sweep that needs the setpoint to land exactly where you asked it. Five preset storage groups (M1–M5), shutdown memory, OVP \/ OCP \/ OTP per channel, and a Digital I\/O hardware ON\/OFF pin pair round out a programmable supply built for benches that have to behave the same way every time. For 5A per adjustable channel, see the UDP3305C; for the knob-only manual variant, see the UDP3303A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Channels, 195W Total — SCPI Programmable\u003c\/strong\u003e — CH1 and CH2: 0–30V \/ 0–3A adjustable. CH3: switchable 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A. SCPI control over USB-Device or RS-232.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Device + RS-232 with SCPI\u003c\/strong\u003e — Back-panel data interfaces for PC connection. Standard accessories include both a USB cable (UT-D14) and RS-232 communication line — pick the bus your test rig already uses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming Accuracy ≤0.1% + 30 mV\u003c\/strong\u003e — Voltage programming accuracy ≤0.1% + 30 mV; current programming accuracy ≤0.5% + 2 mA. Set value matches output value across the full range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH3 Logic-Rail Selector\u003c\/strong\u003e — Single front-panel button cycles CH3 through 1.8V \/ 2.5V \/ 3.3V \/ 5V at 3.2A. CMOS, microcontroller cores, legacy TTL, USB-class — covered without sacrificing CH1\/CH2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Topology, ≤1 mVrms Ripple\u003c\/strong\u003e — Clean DC output for low-noise analog work. Load regulation ≤0.01% + 3 mV in CV mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 mV \/ 1 mA Resolution\u003c\/strong\u003e — Four-digit voltage and current display per channel on EBTN LCD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries, Parallel, and Tracking Modes\u003c\/strong\u003e — Combine CH1+CH2 for up to 60V series or 6A parallel from the front panel. SCPI exposes the same modes for automated test integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOVP \/ OCP \/ OTP Protection\u003c\/strong\u003e — Configurable per-channel thresholds, plus over-temperature shutdown and keypad lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFive Preset Storage Groups\u003c\/strong\u003e — M1–M5 store full instrument states for fast bench setup. Shutdown memory restores last settings on power-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-Panel 5V\/2A USB Charging Port (CH4)\u003c\/strong\u003e — Independent 5V\/2A USB-A charging output. Charging output only — the data interfaces are USB-Device and RS-232 on the back panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Output Disable via Digital I\/O\u003c\/strong\u003e — Two-pin Digital I\/O terminal for emergency cutoff and external interlock circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eCH3 Logic-Rail Selector — One Button, Four Voltages\u003c\/h3\u003e\n\u003cp\u003eMost three-channel bench supplies give you two adjustable channels and a fixed 5V rail you'll resent the moment you need 3.3V. The UDP3303C's CH3 cycles between 1.8V, 2.5V, 3.3V, and 5V at 3.2A — covering CMOS logic, modern microcontroller cores, legacy TTL, and USB-class devices — at a single front-panel button press. CH1 and CH2 stay free for the analog work the linear topology is genuinely good at — op-amp rails, sensor bias, charge-pump references, audio circuits — while CH3 handles whatever digital subsystem the project also needs powered. One supply, two adjustable analog rails, one switchable digital rail, all labeled, all protected, all SCPI-controllable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000-buttons.jpg\" alt=\"UNI-T UDP3303C — ch3 logic-rail selector\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UDP3303C — ch3 logic-rail selector\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000-buttons.jpg\" alt=\"UNI-T UDP3303C — ch3 logic-rail selector\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UDP3303C — ch3 logic-rail selector\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000_save_recall.jpg\" alt=\"UNI-T UDP3303C — scpi programmable for repeatable bench work\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUNI-T UDP3303C — scpi programmable for repeatable bench work\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eSCPI Programmable for Repeatable Bench Work\u003c\/h3\u003e\n\u003cp\u003eThe UDP3303C is the programmable counterpart to the UDP3303A — same hardware, same protection, same CH3 logic-rail selector — with a back-panel USB-Device port and RS-232 added for SCPI control. Script the rails over USB or RS-232, capture readbacks, document the run, and repeat it tomorrow morning the same way. Programming accuracy holds inside ≤0.1% + 30 mV on voltage and ≤0.5% + 2 mA on current — fine enough for IoT sleep-mode current characterization, battery-charge cut-off testing, and any sweep that needs the setpoint to land where you asked it to. Five preset storage groups (M1–M5) and a Digital I\/O hardware ON\/OFF pin pair round out a programmable supply built for benches that have to behave the same way every time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/udp3000_save_recall.jpg\" alt=\"UNI-T UDP3303C — scpi programmable for repeatable bench work\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUNI-T UDP3303C — scpi programmable for repeatable bench work\u003c\/span\u003e\n\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-app-grid\"\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eR\u0026amp;D Bench \u0026amp; Prototyping\u003c\/h3\u003e\n\u003cp\u003eThree rails (two adjustable, one switchable digital) with SCPI control script the bench setup directly from your test framework. Linear topology and ≤1 mVrms ripple keep supply noise out of measurement on op-amp characterization, ADC reference rails, and sensor-bridge excitation work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eAutomated Test Lab Integration\u003c\/h3\u003e\n\u003cp\u003eSCPI over USB-Device or RS-232 integrates with LabVIEW, Python-VISA, and shell-driven test frameworks. Five preset storage groups keep frequently used test setups one command away. Programming accuracy ≤0.1% + 30 mV keeps automated sweeps repeatable across runs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eTeaching Labs \u0026amp; Automated Lab Exercises\u003c\/h3\u003e\n\u003cp\u003eFor curricula that introduce instrument automation alongside instrument operation, the UDP3303C lets a class go from manual front-panel work to scripted SCPI control without changing the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-app-card\"\u003e\n\u003ch3\u003eMixed-Signal Development\u003c\/h3\u003e\n\u003cp\u003eCH1 and CH2 power analog rails at low ripple; CH3 cycles through digital-side voltages without retuning. SCPI lets the test script raise or lower the digital rail while CH1\/CH2 hold the analog supplies steady — useful for power-sequencing and sleep-mode characterization on mixed-signal prototypes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UDP3303A and the UDP3303C?\u003c\/p\u003e\n\u003cp\u003eThe UDP3303C adds SCPI programmability over USB-Device and RS-232. Hardware (channels, voltage, current, power, CH3 logic-rail selector, protection, display, dimensions) is otherwise identical. Choose the UDP3303A if your bench is knob-only; choose the UDP3303C if you need automated test integration. For 5A per adjustable channel instead of 3A, step up to the UDP3305C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UDP3303C have LAN?\u003c\/p\u003e\n\u003cp\u003eNo. The UDP3303C's data interfaces are USB-Device (back-panel SCPI port for PC connection) and RS-232. If your workflow needs LAN with LXI\/web interface, the UDP3000S series adds it on the same linear-PSU platform. The Digital I\/O pin pair on the back panel handles hardware ON\/OFF — useful for external interlocks but not for data communication.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the front-panel USB port for?\u003c\/p\u003e\n\u003cp\u003eIt's a 5V\/2A USB-A charging output (CH4) — for charging a phone or powering a USB-powered demo board. It is explicitly not a data interface. The SCPI data ports are on the back panel: USB-Device and RS-232.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan the UDP3303C run automated voltage\/current sweeps?\u003c\/p\u003e\n\u003cp\u003eYes — SCPI control over USB-Device or RS-232 supports remote voltage and current setpoint commands plus readbacks, and the five preset storage groups (M1–M5) keep frequently used configurations available for fast recall. For complex programmable waveform output (list\/delayer functions), the UDP3000S series adds those capabilities on the same linear platform.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhy a linear supply instead of switching for SCPI work?\u003c\/p\u003e\n\u003cp\u003eLinear topology produces fundamentally cleaner output — no switching frequency, no harmonic spurs, ripple under 1 mVrms. SCPI control gives you automation; linear regulation keeps the output clean enough for the precision measurements that automated test usually exists to take in the first place. The trade-off is lower efficiency and more heat, which at 195W bench-supply scale is not a meaningful constraint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's included with the UDP3303C?\u003c\/p\u003e\n\u003cp\u003eThe UDP3303C ships with the instrument, power cord, USB communication cable (UT-D14), RS-232 communication line, alligator clip test leads, English user manual Ships from authorized US dealer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDP3303C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 programmable (CH1, CH2 adjustable; CH3 selectable) + CH4 USB charging output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1, CH2 Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1, CH2 Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH3 Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8V \/ 2.5V \/ 3.3V \/ 5V (±3%, fine-tunable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH3 Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH4 USB Charging Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V \/ 2A (front-panel USB charging output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CV)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.01% + 3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Regulation (CC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.2% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Accuracy (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.1% + 30 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgramming Accuracy (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.5% + 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (Voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1 mVrms (20Hz–20MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple \u0026amp; Noise (Current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤3 mArms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤300 ppm\/°C (V\/I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Mode (CH1+CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 60V (CH1+CH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Mode (CH1+CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 6A (CH1+CH2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEBTN LCD, 4-digit voltage + current per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — SCPI over USB-Device or RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-Device, RS-232, Digital I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 preset storage groups (M1–M5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOVP, OCP (per-channel, configurable), OTP, keypad lock, shutdown memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 \/ 120 \/ 220 \/ 230V ±10%, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 × 168 × 347 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=34\"\u003eUDP3303C Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":67601531404539,"sku":"181730080304X","price":365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UDP3303C_Cables.jpg?v=1790709350"},{"product_id":"ute323-3-ch-high-precision-digital-power-meter","title":"UTE323 3-Ch High-Precision Digital Power Meter","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTE323 Series\u003c\/strong\u003e is a three-channel high-precision digital power meter for three-phase and multi-rail power measurement. Three synchronized measurement channels capture a full three-phase system — or three independent DC\/AC rails — in one instrument, with per-channel and total power, power factor, frequency, energy and harmonics.\u003c\/p\u003e\n\u003cp\u003eIt samples at 300 kSa\/s across a DC to 300 kHz bandwidth and supports every standard wiring configuration (1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A). The UTE323 communicates over RS-232; the UTE323G substitutes GPIB for instrument-bus racks. Measurement firmware and accuracy are identical.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTE323 Series\u003c\/h2\u003e\n\u003cp\u003eTwo models, one platform. They differ only by communication interface — channel count, accuracy, 300 kSa\/s sampling, wiring modes and harmonic analysis are identical:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:20%\"\u003e\n\u003ccol style=\"width:14%\"\u003e\n\u003ccol style=\"width:40%\"\u003e\n\u003ccol style=\"width:26%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003cth\u003eWiring Modes\u003c\/th\u003e\n\u003cth\u003eCommunication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTE323G\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ \u003cstrong\u003eGPIB\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eChoose by the interface your test bench uses.\u003c\/p\u003e\n\u003cp\u003eNeed single-phase high-voltage measurement, or a compact panel meter? See the single-channel UTE310 Series (600 V \/ 1000 V single-phase) or the UTE9800+ Series compact power meters — distinct instrument lines for different measurement needs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"product-key-features\"\u003e\n\u003cli\u003eThree synchronized measurement channels — full three-phase or three independent rails\u003c\/li\u003e\n\u003cli\u003eWiring modes: 1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/li\u003e\n\u003cli\u003e300 kSa\/s synchronous sampling on all channels\u003c\/li\u003e\n\u003cli\u003eDC to 300 kHz measurement bandwidth\u003c\/li\u003e\n\u003cli\u003ePer-channel and total power, PF, frequency and energy\u003c\/li\u003e\n\u003cli\u003eHarmonic analysis to the 50th order, per channel\u003c\/li\u003e\n\u003cli\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/li\u003e\n\u003cli\u003e5-inch TFT-LCD with simultaneous waveform display\u003c\/li\u003e\n\u003cli\u003eD\/A analog output for external recording\u003c\/li\u003e\n\u003cli\u003eRS-232 standard; GPIB on UTE323G in its place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTE323 Series Details\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eUTE323 multi-parameter measurement display\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eThree-Phase \u0026amp; Multi-Rail Wiring Modes\u003c\/h3\u003e\n\u003cp\u003eThe UTE323 supports every standard configuration — single-phase two\/three-wire, three-phase three\/four-wire and the 3V3A method. One instrument measures a complete three-phase inverter output, a three-rail DC bus or three independent converters without re-cabling between standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Display_sq.jpg?v=1770232639\" alt=\"UTE323 multi-parameter measurement display\"\u003e\u003cspan class=\"lightbox-caption\"\u003eUTE323 multi-parameter measurement display\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSynchronous 300 kSa\/s Multi-Channel Sampling\u003c\/h3\u003e\n\u003cp\u003eAll three channels sample synchronously at 300 kSa\/s, so phase relationships and per-phase power are measured against a common time base — essential for true three-phase power and imbalance measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_Sample_rate_sq.jpg?v=1770232639\" alt=\"300 kSa\/s synchronous sampling on all channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003e300 kSa\/s synchronous sampling on all channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eDC to 300 kHz Wide-Bandwidth Measurement\u003c\/h3\u003e\n\u003cp\u003eThe wide DC–300 kHz bandwidth keeps switching content and harmonics in the per-phase power calculation, so three-phase inverter and drive measurements reflect the real waveform rather than the fundamental alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_wide_bandwidth_sq.jpg?v=1770232639\" alt=\"DC to 300 kHz wide-bandwidth measurement\"\u003e\u003cspan class=\"lightbox-caption\"\u003eDC to 300 kHz wide-bandwidth measurement\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003ePer-Channel Harmonic Analysis\u003c\/h3\u003e\n\u003cp\u003eHarmonic analysis to the 50th order runs on each channel independently, quantifying per-phase distortion on three-phase rectifier and drive front ends.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_harmonics_sq.jpg?v=1770232639\" alt=\"Harmonic analysis to the 50th order, per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eHarmonic analysis to the 50th order, per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003ePer-Channel Energy Integration\u003c\/h3\u003e\n\u003cp\u003eWatt-hour and amp-hour integration accumulate per channel for three-phase efficiency runs and long-duration multi-rail energy profiling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_integral_sq.jpg?v=1770232639\" alt=\"Energy integration (Wh \/ Ah) per channel\"\u003e\u003cspan class=\"lightbox-caption\"\u003eEnergy integration (Wh \/ Ah) per channel\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSimultaneous Waveform Display\u003c\/h3\u003e\n\u003cp\u003eThe 5-inch display shows all channel waveforms together, confirming phase rotation and wiring before the measurement is trusted.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eSimultaneous waveform display across channels\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_display_wave_sq.jpg?v=1770232639\" alt=\"Simultaneous waveform display across channels\"\u003e\u003cspan class=\"lightbox-caption\"\u003eSimultaneous waveform display across channels\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\u003cimg class=\"product-image-thumb\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\" loading=\"lazy\"\u003e\u003cfigcaption class=\"product-figcaption\"\u003eD\/A analog output for external recording\u003c\/figcaption\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eD\/A Output\u003c\/h3\u003e\n\u003cp\u003eA D\/A analog output drives a chart recorder or DAQ for long-term trend logging of any measured channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTE323_da_sq.jpg?v=1770232639\" alt=\"D\/A analog output for external recording\"\u003e\u003cspan class=\"lightbox-caption\"\u003eD\/A analog output for external recording\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eGPIB in Place of RS-232 — UTE323G\u003c\/h3\u003e\n\u003cp\u003eThe UTE323G substitutes a GPIB (IEEE-488) port for RS-232 — it does not add GPIB alongside it. USB and LAN are present on both models, so if you automate over LAN the base UTE323 already covers you; the UTE323G is for racks built on a GPIB instrument bus.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eThree-Phase Inverter \u0026amp; Motor-Drive Efficiency\u003c\/h3\u003e\n\u003cp\u003eMeasure three-phase output power and per-phase imbalance on inverter and motor-drive designs in a single instrument, with synchronous sampling that holds phase relationships true.\u003c\/p\u003e\n\u003ch3\u003eMulti-Rail \u0026amp; Multi-Converter Test\u003c\/h3\u003e\n\u003cp\u003eThree independent channels measure three DC\/AC rails or three converters at once — one instrument instead of three single-channel meters on a multi-output power-electronics bench.\u003c\/p\u003e\n\u003ch3\u003eProduction \u0026amp; QA Test Bench\u003c\/h3\u003e\n\u003cp\u003ePer-channel limits, energy integration and a single RS-232\/GPIB or LAN connection make the UTE323 a compact end-of-line and QA power-test station for small test labs and consultancies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003cp\u003eUTE-series test cables support safe three-phase connection. Pair the UTE323 with UNI-T programmable sources and electronic loads for a complete three-phase power-characterization bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eCan the UTE323 measure a full three-phase system at once?\u003c\/h3\u003e\n\u003cp\u003eYes. Three synchronized channels and the 3P3W \/ 3P4W \/ 3V3A wiring modes measure a complete three-phase system in one instrument.\u003c\/p\u003e\n\u003ch3\u003eCan the three channels measure independent rails instead of one three-phase system?\u003c\/h3\u003e\n\u003cp\u003eYes. The three channels can measure three independent DC\/AC rails or converters simultaneously.\u003c\/p\u003e\n\u003ch3\u003eDoes the UTE323G add GPIB on top of RS-232?\u003c\/h3\u003e\n\u003cp\u003eNo — it substitutes GPIB for RS-232. USB and LAN are on both models; the UTE323G is for GPIB-bus racks.\u003c\/p\u003e\n\u003ch3\u003eDoes each channel measure harmonics?\u003c\/h3\u003e\n\u003cp\u003eYes — per-channel harmonic analysis to the 50th order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTE323 \/ UTE323G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (synchronous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75mV – 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5mA – 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5W – 12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300kSa\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC, 0.1Hz – 300kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P2W \/ 1P3W \/ 3P3W \/ 3P4W \/ 3V3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1st – 50th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-inch TFT-LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface (UTE323G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB \/ LAN \/ GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=116\"\u003eUTE323 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BB x3\u003c\/li\u003e\n  \u003cli\u003eUT-L0110-BU x3\u003c\/li\u003e\n  \u003cli\u003eRed\/Black termals x6\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368464445691,"sku":"182700300017X","price":3699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTE323-1.png?v=1792619151"},{"product_id":"usg3045v-p-4-5-ghz-vector-rf-signal-generator-with-mechanical-attenuator","title":"USG3045V-P 4.5 GHz Vector RF Signal Generator with Mechanical Attenuator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe USG3045V-P is a 4.5 GHz vector signal generator covering 9 kHz to 4.5 GHz with 0.001 Hz frequency resolution and a level range of −135 dBm to +25 dBm. Single-sideband phase noise typically \u0026lt; −122 dBc\/Hz at 1 GHz \/ 20 kHz offset, amplitude accuracy ≤0.7 dB (Typ.), and frequency switching ≤40 ms make it suitable for both bench R\u0026amp;D and automated test workflows. The USG3045V-P supports full vector modulation with a 150 MHz real-time baseband bandwidth.\u003c\/p\u003e\n\u003cp\u003eAs a vector signal generator, the USG3045V-P adds a full real-time digital modulation engine to the analog signal-source foundation. With 150 MHz of baseband bandwidth, real-time QAM\/PSK\/FSK\/ASK generation, ARB waveform-file playback, multi-carrier and multi-tone modes, and AWGN noise injection for receiver testing, the USG3045V-P addresses protocol-aware wireless R\u0026amp;D and commercial production test for 5G NR, WLAN, LTE, Bluetooth, ZigBee, and Z-Wave devices. Typical QPSK EVM is 0.4% at a 1 GHz carrier; 5G NR ACPR is typically \u0026lt; −55 dBc at a 3.8 GHz carrier. The USG3045V-P is suited to wireless-device R\u0026amp;D, calibration labs running spec verification, and commercial production-test stations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 4.5 GHz CW Frequency Range\u003c\/strong\u003e — \u0026gt;5 MHz to 4.5 GHz in I\/Q mode; 0.001 Hz resolution across the full band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−135 dBm to +25 dBm Level Range\u003c\/strong\u003e — 160 dB dynamic range with 0.01 dB resolution and ≤0.7 dB amplitude accuracy typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Noise \u0026lt; −122 dBc\/Hz at 1 GHz\u003c\/strong\u003e — single-sideband phase noise typical at 20 kHz offset for sensitive vector measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Step Attenuator Standard\u003c\/strong\u003e — 0 to 110 dB range with 10 dB steps; mechanical attenuator delivers maximum absolute output power across all bands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% at 1 GHz typical; 5G NR ACPR \u0026lt; −55 dBc at 3.8 GHz typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 MHz Real-Time Baseband Bandwidth\u003c\/strong\u003e — internal vector engine covers wideband modulation envelopes including Wi-Fi 6\/7 channel widths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Modulation\u003c\/strong\u003e — QAM, PSK, FSK, ASK with custom filter shapes (RRC, Gaussian, user-defined) and filling settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/strong\u003e — user-defined waveform replay with carrier-aggregated and multi-tone test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time AWGN Injection\u003c\/strong\u003e — precise SNR control for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave IoT Generation\u003c\/strong\u003e — protocol-aware signal generation for IoT module test and incoming inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile-Comm Protocol Simulation\u003c\/strong\u003e — 5G NR, WLAN, LTE, Bluetooth, IoT waveform support with UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAM, FM, and ΦM Analog Modulation\u003c\/strong\u003e — internal, external, or internal + external sources alongside the digital engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO High-Stability Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging, ≤±10 ppb temperature effects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 50 MHz Function\/Arbitrary Waveform Generator\u003c\/strong\u003e — standard waveforms, sweep, and modulation from a separate LF output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-Inch Touch Screen with Signal-Flow Interface\u003c\/strong\u003e — full touch control with intuitive signal-flow-diagram interaction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, USB Host, USB Device, I\/Q Baseband I\/O Standard\u003c\/strong\u003e — full SCPI automation via LabVIEW, Python, MATLAB, Excel; GPIB available as a factory-installed hardware option (must be ordered with the instrument).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Control + Device Manager\u003c\/strong\u003e — browser-based remote access plus free PC management software (V2.5.0+).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Pulse Modulation\u003c\/strong\u003e — 80 dB on-off ratio with customizable pulse trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Narrow-Pulse Generator\u003c\/strong\u003e — 40 ns minimum width with 10 ns resolution for radar component test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional USB Power Sensor Support (USG3000-PK)\u003c\/strong\u003e — license-activated readback and flatness correction with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE | cETLus | RoHS Compliant\u003c\/strong\u003e — meets common North American and European safety and environmental standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eHigh Spectral Purity for Sensitive Receiver and Component Test\u003c\/h3\u003e\n\u003cp\u003eSingle-sideband phase noise typically below −122 dBc\/Hz at 1 GHz with a 20 kHz offset is the headline spectral-purity figure that determines whether a generator can stimulate the device under test without contaminating the measurement. Low close-in phase noise matters for adjacent-channel rejection testing on receivers, image-rejection on mixers, and any narrowband filter characterization where the stimulus must be cleaner than the device's own passband behavior.\u003c\/p\u003e\n\u003cp\u003eThe clock-source architecture supports ≤±0.2 ppm\/year aging rate, ≤±10 ppb temperature effects, and ≤±10 ppb line-voltage sensitivity — frequency reference stable enough for calibration-cycle use without external 10 MHz lock, though both 10 MHz reference input and 10 MHz output are available on the rear panel for multi-instrument synchronization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG3000-series RF generator\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG3000-series RF generator\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-vector_modulation.gif\" alt=\"USG3000V vector modulation display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-vector_modulation.gif\" alt=\"USG3000V vector modulation display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eReal-Time Vector Modulation with 150 MHz Baseband Bandwidth\u003c\/h3\u003e\n\u003cp\u003eThe internal vector engine provides 150 MHz of real-time baseband bandwidth and generates real-time QAM, PSK, FSK, and ASK modulation with user-configurable filter shapes (RRC, Gaussian, custom). User-defined custom modulation types with adjustable filling settings extend coverage across all critical communication formats. With QPSK at a 1 GHz carrier, measured EVM is 0.4% typical — calibration-grade. For 5G NR at 3.8 GHz, ACPR is \u0026lt; −55 dBc typical, so the instrument's own spectral regrowth doesn't dominate measurements on 5G receiver and transmitter validation work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V_2.png\" alt=\"USG3000V front panel showing level control\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e160 dB output range with three ALC modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V_2.png\" alt=\"USG3000V front panel showing level control\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e160 dB output range with three ALC modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide Output Range — +25 dBm Maximum, −135 dBm Minimum\u003c\/h3\u003e\n\u003cp\u003eOutput settable range is −135 dBm to +25 dBm with 0.01 dB resolution. Maximum output power varies by frequency band and attenuator type: in the 250 MHz to 1.2 GHz band, the electronic attenuator delivers +20 dBm typical, while the mechanical attenuator option reaches +24 dBm. Above 1.2 GHz and through 3.6 GHz, electronic output is +18 dBm; mechanical-attenuator output is +22 dBm.\u003c\/p\u003e\n\u003cp\u003eThree ALC (Automatic Level Control) modes are available: ALC Auto selects the optimum mode for the current operating state; ALC On runs closed-loop level control for CW, FM, and ΦM operation; ALC S\u0026amp;H (Off) freezes the closed-loop value on frequency or amplitude transitions, useful for AM and pulse modulation work where ALC interaction with the modulation envelope is undesirable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-scanning_methods.gif\" alt=\"USG3000V ARB and multi-carrier mode displays\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-scanning_methods.gif\" alt=\"USG3000V ARB and multi-carrier mode displays\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/h3\u003e\n\u003cp\u003eARB playback mode plays back user-defined arbitrary waveform data at variable sampling rates, with baseband preview that displays the waveform in both time and frequency domains before transmission. ARB multi-carrier mode splits wideband signals into multiple narrowband subcarriers, each independently modulated — simplifying construction of carrier-aggregated LTE\/5G NR signals and multi-channel interference environments without external signal combiners. Multi-tone mode generates multiple frequency components simultaneously for intermodulation distortion testing, multi-channel receiver characterization, and spectrum-density emulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eReal-Time AWGN Injection for Receiver Sensitivity Testing\u003c\/h3\u003e\n\u003cp\u003eThe instrument provides both pure-noise output and real-time additive white Gaussian noise injection, with precise signal-to-noise power control — no separate noise measurement step required before each test. For receiver sensitivity verification, blocking and selectivity testing, and dynamic-range characterization, AWGN injection is the workhorse stimulus. Controlling SNR digitally inside the same instrument that generates the modulated signal removes a measurement-uncertainty drift source on long-running production sequences.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-AWGN_white_guassian_noise.gif\" alt=\"USG3000V AWGN spectrum display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-AWGN_white_guassian_noise.gif\" alt=\"USG3000V AWGN spectrum display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-signal_studio_support.gif\" alt=\"USG3000V SignalStudio software upper-computer interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-signal_studio_support.gif\" alt=\"USG3000V SignalStudio software upper-computer interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eIoT and Mobile Communication Protocol Generation\u003c\/h3\u003e\n\u003cp\u003eNative ZigBee and Z-Wave signal generation is built into the instrument's vector engine with flexible modulation parameter settings per protocol — eliminating third-party IoT signal source dependencies for incoming inspection, R\u0026amp;D prototyping, and production-line stimulus. For 5G NR, WLAN, LTE, and Bluetooth waveforms, the instrument pairs with UNI-T's SignalStudio software (sold separately) for protocol-compliant signal simulation across commercial wireless-device R\u0026amp;D and compliance pre-screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOptional Pulse and Narrow-Pulse Generation\u003c\/h3\u003e\n\u003cp\u003eThe optional pulse modulation package adds an on-off ratio of up to 80 dB with customizable pulse-train definitions, enabling single-instrument pulsed RF for radar component test, time-gated stimulus, and EMC pulsed-emission work. The narrow-pulse generator option extends capability to a 40 ns minimum width with 10 ns resolution, addressing test requirements of millimeter-wave radar components used in commercial automotive ADAS suppliers and short-range industrial radar systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG3000V pulse modulation output waveform\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG3000V pulse modulation output waveform\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUSB Power Sensor Support — Flatness Correction at the DUT Plane (Option USG3000-PK)\u003c\/h3\u003e\n\u003cp\u003eThe optional \u003cstrong\u003eUSG3000-PK\u003c\/strong\u003e software license enables the instrument to read and display power measurements from a user-supplied USB power sensor connected to the front-panel USB Host port. The license is delivered as a file that installs from a USB stick via the instrument's Option Install menu, following the same activation workflow as the Pulse Modulation and GPIB options. A USB power sensor is not included; the user supplies a compatible sensor.\u003c\/p\u003e\n\u003cp\u003eOnce activated, the Power Sensor menu provides measurement frequency entry, frequency coupling to the current RF carrier (with multiplier and offset for harmonic and IF-shifted measurements), measurement averaging, and amplitude offset entry — the standard tools for flatness correction and cable-loss compensation at the DUT plane. The amplitude offset entry is particularly useful when the signal path between the generator and the device under test includes cables, attenuators, or amplifiers: the displayed power reflects what the DUT actually sees, not what leaves the generator's output connector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-power_de-embedding.jpg\" alt=\"USG3000V USB power sensor measurement and path-loss compensation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-power_de-embedding.jpg\" alt=\"USG3000V USB power sensor measurement and path-loss compensation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5-Inch Touch UI with Signal-Flow Interface\u003c\/h3\u003e\n\u003cp\u003eA 5.0-inch high-resolution touch screen provides full touch control over every function except the power switch. The interface is built around a signal-flow diagram — the user sees modulation source, modulation type, sweep mode, and RF carrier as a connected chain rather than as scattered menu items. For an instrument with this much configurable surface area (multiple modulation paths, multiple sweep modes, multiple digital protocols, ARB and multi-carrier work, optional pulse and power-meter kits), the signal-flow paradigm meaningfully cuts setup time on R\u0026amp;D benches where the test configuration changes hour-to-hour.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-flat_interface.gif\" alt=\"USG3000V touch UI with flat signal-flow interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-flat_interface.gif\" alt=\"USG3000V touch UI with flat signal-flow interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-computer_interface.gif\" alt=\"USG3000V computer interface and automation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000V-computer_interface.gif\" alt=\"USG3000V computer interface and automation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFull Automation — SCPI, Web Control, Device Manager\u003c\/h3\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option and must be ordered with the instrument. All ports speak the standard SCPI command set, enabling remote operation from any automation-capable host. Test engineers commonly drive the instrument from LabVIEW, Python, MATLAB, or even Excel macros for batch command execution.\u003c\/p\u003e\n\u003cp\u003eWeb Control provides browser-based remote access — point a PC or mobile browser at the instrument's IP address and the full front-panel UI is available remotely, with no client install. Device Manager (UNI-T's free PC software, V2.5.0 and higher) manages the instrument via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB, and handles batch instrument inventories on a multi-station test floor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (CW mode)\u003c\/th\u003e\n\u003ctd\u003e9 kHz to 4.5 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (I\/Q mode)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 4.5 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase offset step\u003c\/th\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency switching speed\u003c\/th\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel settable range\u003c\/th\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplitude accuracy (Typ.)\u003c\/th\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAttenuator type\u003c\/th\u003e\n\u003ctd\u003eMechanical step attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise (Typ.)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOscillator aging rate\u003c\/th\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature effects\u003c\/th\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial calibration accuracy\u003c\/th\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog modulation\u003c\/th\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital modulation\u003c\/th\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBaseband bandwidth\u003c\/th\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVector modulation EVM (Typ.)\u003c\/th\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e5G NR ACPR (Typ.)\u003c\/th\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eARB modes\u003c\/th\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise injection\u003c\/th\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIoT protocols (native)\u003c\/th\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile-comm protocol simulation\u003c\/th\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse modulation (option)\u003c\/th\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNarrow pulse (option)\u003c\/th\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB power sensor (option USG3000-PK)\u003c\/th\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSweep modes\u003c\/th\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStep sweep points\u003c\/th\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList sweep points\u003c\/th\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDwell time\u003c\/th\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilt-in AWG\u003c\/th\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference (10 MHz)\u003c\/th\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard interfaces\u003c\/th\u003e\n\u003ctd\u003eLAN, USB Host, USB Device, I\/Q baseband I\/O (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote control\u003c\/th\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRoHS\u003c\/th\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice. \"Typ.\" values represent typical performance and are not warranted.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eProtocol-Aware Wireless Device Development\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-Power Wireless R\u0026amp;D\u003c\/strong\u003e — Mechanical attenuator delivers +24 dBm absolute output at 1.2 GHz for amplifier saturation and high-side wireless front-end characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQAM, PSK, FSK, ASK Real-Time Digital Modulation\u003c\/strong\u003e — Custom filter shapes (RRC, Gaussian, user-defined) for protocol-specific test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Multi-Carrier Mode\u003c\/strong\u003e — Carrier-aggregated LTE \/ 5G NR test signals without external combiners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAWGN Injection\u003c\/strong\u003e — Real-time noise injection for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial Production Test and Calibration Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-Power Vector Modulation Test\u003c\/strong\u003e — Mechanical attenuator delivers calibrated +24 dBm at 1.2 GHz for wireless front-end compression and 1 dB-CP verification under vector modulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration-Grade Vector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% typical at 1 GHz supports commercial cal-lab spec verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Power Sensor Integration\u003c\/strong\u003e — Optional USG3000-PK license activates flatness correction at the DUT plane with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging suits calibration-cycle scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIoT Device R\u0026amp;D and Compliance Pre-Screen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher-Power IoT Receiver-Side Stimulus\u003c\/strong\u003e — Mechanical attenuator headroom covers IoT module compression-test points and gateway-side receiver validation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave Generation\u003c\/strong\u003e — Flexible modulation parameter control (modulation count, modulation method) per protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio Protocol Simulation\u003c\/strong\u003e — 5G NR \/ WLAN \/ LTE \/ Bluetooth waveform support via UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Tone Mode\u003c\/strong\u003e — IoT mesh-network coexistence and interference testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSG3045V-P RF signal generator\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB data cable\u003c\/li\u003e\n\u003cli\u003eQuick start guide and certificate of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PM\u003c\/strong\u003e — Pulse modulation option (license-activated; 80 dB on-off ratio, customizable pulse trains).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PG\u003c\/strong\u003e — Narrow-pulse generator option (license-activated; 40 ns minimum width, 10 ns resolution).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-PK\u003c\/strong\u003e — USB power sensor support option (license-activated; user supplies a compatible USB power sensor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG3000-GPIB\u003c\/strong\u003e — GPIB interface hardware option; adds a factory-installed IEEE 488 port for legacy automation systems. Must be ordered with the instrument — cannot be added after purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio + waveform licenses\u003c\/strong\u003e — UNI-T SignalStudio software (sold separately) with optional waveform-playback license packages: BT (Bluetooth), OFDM (custom OFDM), DM (custom digital modulation), VIOT (extended IoT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSMA cables and adapters\u003c\/strong\u003e — UT-W01-6GHz NJ-NJ DC-6 GHz cable, UT-W02-6GHz SMAJ-NJ DC-6 GHz cable, UT-C01-6GHz SMA-N adapter, UT-C02-4GHz N-BNC adapter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUSG3045M — 4.5 GHz analog, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3045M-P — 4.5 GHz analog, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065M — 6.5 GHz analog, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065M-P — 6.5 GHz analog, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3045V — 4.5 GHz vector, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065V — 6.5 GHz vector, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG3065V-P — 6.5 GHz vector, mechanical attenuator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the V-series and the M-series?\u003c\/p\u003e\n\u003cp\u003eThe M-series is an analog RF signal generator (AM, FM, ΦM with optional pulse and narrow-pulse modulation) suited to amplifier and filter R\u0026amp;D, receiver calibration, and pulsed-RF component test. The V-series adds a full real-time digital modulation engine on the same analog foundation: 150 MHz baseband bandwidth, QAM\/PSK\/FSK\/ASK, ARB playback with multi-carrier, AWGN injection, and native ZigBee\/Z-Wave IoT generation. SignalStudio software (sold separately) extends V-series coverage to 5G NR\/WLAN\/LTE\/Bluetooth. M addresses component-level stimulus; V addresses protocol-aware wireless device development.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the USG3045V-P and the non-−P variant?\u003c\/p\u003e\n\u003cp\u003eThe USG3045V-P ships with an mechanical step attenuator as standard; the non-−P variant substitutes an electronic step attenuator. Both provide 0–110 dB range with 10 dB steps. Mechanical attenuators deliver higher absolute output power (~+4 dB above electronic at the 250 MHz–3.6 GHz bands); electronic attenuators switch faster and have longer service life. Choose mechanical for maximum output headroom, electronic for high-cycle automation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat automation interfaces are standard?\u003c\/p\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option (must be ordered with the instrument). All ports support the standard SCPI command set, so the instrument drops into any existing automated test station (LabVIEW, Python, MATLAB, Excel) without protocol translation. Web Control provides browser-based remote access via the instrument's IP address — no client install required, works from PC and mobile. UNI-T's free Device Manager PC software (V2.5.0 and higher) handles batch instrument inventories via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does the USG3000-PK power sensor option provide?\u003c\/p\u003e\n\u003cp\u003eUSG3000-PK is a software license that activates USB power sensor support in the instrument. The user connects a compatible USB-TMC power sensor (sold separately) to the front-panel USB Host port; the instrument displays the power measurement on its own screen with menu controls for measurement frequency, frequency coupling (multiplier + offset), amplitude offset for path-loss compensation, and averaging. The primary use case is flatness correction and cable-loss compensation at the DUT plane — the amplitude offset entry compensates for cables and adapters between the generator and the device under test. License is activated via UNI-T's standard option-install workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (CW mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 4.5 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (I\/Q mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 4.5 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase offset step\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency switching speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel settable range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuator type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical step attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillator aging rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature effects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial calibration accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseband bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVector modulation EVM (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5G NR ACPR (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARB modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIoT protocols (native)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile-comm protocol simulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse modulation (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNarrow pulse (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB power sensor (option USG3000-PK)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDwell time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference (10 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLAN, USB Host, USB Device, I\/Q baseband I\/O (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=121\"\u003eUSG3045V-P Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUSG3000-GPIB — GPIB Adapter Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PG — Narrow Pulse Generator Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PK — Power Meter Option\u003c\/li\u003e\n  \u003cli\u003eUSG3000-PM — Pulse Modulation Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368464838907,"sku":"181300200037X","price":18999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/USG3000V_1_sq.jpg?v=1792619165"},{"product_id":"utg9504t-500-mhz-4ch-elite-series-arbitrary-waveform-generator","title":"UTG9504T+ 500 MHz 4Ch Elite-Series Arbitrary Waveform Generator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTG9504T+\u003c\/strong\u003e is a four-channel arbitrary waveform generator with a maximum sine output of 500 MHz, built around a 16-bit DAC and a 2.5 GSa\/s sample rate (2× interpolation). All four channels deliver equal performance with full 20 Vpp output (high-Z), and an 8 pts to 128 Mpts per-channel arbitrary memory supports long-form custom stimulus. A 10.1-inch capacitive touch display replaces menu-driven navigation with direct parameter manipulation.\u003c\/p\u003e\n\u003cp\u003e170 MHz square and 120 MHz pulse output, 1 µHz frequency resolution across the full 500 MHz range, harmonic distortion below 0.07% (DC to 20 kHz), and an 800 MHz hardware frequency counter. Fifteen analog and digital modulation types — including 3FSK, 4FSK, QAM, and the full BPSK \/ QPSK \/ OSK set. Linear, logarithmic, list, and step sweep. Three burst modes. Advanced Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression functions. Over 200 built-in arbitrary waveforms with SPI \/ I²C \/ UART digital-protocol output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e500 MHz sine \/ 170 MHz square \/ 120 MHz pulse\u003c\/strong\u003e — four-channel output with 1 µHz frequency resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour equal-performance channels, 20 Vpp\u003c\/strong\u003e — every channel delivers the full output envelope; independent or combined operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s sample rate, 16-bit DAC\u003c\/strong\u003e — with 2× interpolation; 8 pts to 128 Mpts per-channel arbitrary memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic distortion below 0.07%\u003c\/strong\u003e — low distortion with −80 dBc spurious-free dynamic range and high SNR on large DC offsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 modulation types\u003c\/strong\u003e — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM — analog and digital in one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e — Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression-based waveform generation built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-dynamic pulse, fast edges\u003c\/strong\u003e — 100 ps edge-time adjustment, 3 ns minimum pulse width, per-pulse edge control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRBS PN3 to PN33\u003c\/strong\u003e — 1 µbps to 300 Mbps with adjustable edge time for serial-link and jitter-tolerance test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800 MHz hardware frequency counter\u003c\/strong\u003e — 100 mHz to 800 MHz, 8-digit, AC \/ DC \/ HF-reject coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 200 built-in arbitrary waveforms\u003c\/strong\u003e — plus SPI, I²C, and UART digital-protocol output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touch display\u003c\/strong\u003e — 1280 × 800; direct parameter manipulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTG9504T+ Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFour Equal-Performance Channels, 20 Vpp\u003c\/h3\u003e\n\u003cp\u003eFour independent channels in the standard configuration, every one delivering identical performance — there is no derated second bank. Each channel produces the full output envelope to 20 Vpp (high-Z) and can run fully independently, so clock, data, trigger, and stimulus can all originate from one instrument at full specification on every channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9504T+ four equal-performance channels, 20 vpp\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour equivalent-performance channels with full 20 Vpp output on every channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9504T+ channel coupling and merging\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFrequency, amplitude, and phase coupling across channels; outputs merge into composite signals.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eChannel Coupling and Merging\u003c\/h3\u003e\n\u003cp\u003eChannels can be freely coupled with configurable frequency, amplitude, and phase relationships (coupling ratio 0.0001 to 10,000), so a parameter change on one channel propagates to its coupled partners by a defined ratio and offset. Outputs can also be merged into arbitrary combinations — for example CH1 = CH1 + CH2 + CH3 + CH4 — producing summed and composite signals from a single instrument without external combiners.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLow-Distortion Output and High SNR\u003c\/h3\u003e\n\u003cp\u003eDigital sampling produces sine, square, ramp, pulse, arbitrary, harmonic, noise, DC, and PRBS waveforms with low distortion and low jitter. Total harmonic distortion stays below 0.07% from DC to 20 kHz, with a spurious-free dynamic range to −80 dBc. A small signal superimposed on a large DC offset retains a high signal-to-noise ratio — useful when the stimulus must be quieter than the device under test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9504T+ low-distortion output and high snr\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTHD below 0.07% (DC to 20 kHz) with −80 dBc spurious-free dynamic range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9504T+ wide-dynamic pulse with fast, independently adjustable edges\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEdge time adjustable in 100 ps steps; 3 ns minimum pulse width; per-pulse edge control.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide-Dynamic Pulse with Fast, Independently Adjustable Edges\u003c\/h3\u003e\n\u003cp\u003eThe pulse generator offers high-precision adjustable edge times with increments as fine as 100 ps and a minimum pulse width of 3 ns (Typ.), generating high harmonic content comparable to a dedicated pulse generator. Edge time can be set independently for each pulse, down to a 2 ns minimum, and pulse jitter stays at 200 ps across the operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Modulation Types in One Instrument\u003c\/h3\u003e\n\u003cp\u003eFifteen analog and digital modulation schemes are built in: AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, and PWM. Each channel supports independent or simultaneous internal\/external modulation and internal\/external\/manual triggering, alongside Linear\/Logarithmic\/List\/Step frequency sweep and N-cycle\/gate\/pulse-train burst.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9504T+ 15 modulation types in one instrument\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFifteen modulation types covering analog and digital schemes, plus sweep and burst.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9504T+ multi-pulse and multi-tone generation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-Pulse: 2–30 pulses with per-pulse edge control. Multi-Tone: 2–8 components.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eMulti-Pulse and Multi-Tone Generation\u003c\/h3\u003e\n\u003cp\u003eMulti-Pulse produces pulse trains of 2 to 30 pulses with independently adjustable edge times and high\/gap times for rapid, precise multi-pulse testing without custom code. Multi-Tone synthesizes 2 to 8 simultaneous frequency components, reproducing real-world multi-frequency signals for nonlinear-distortion analysis, wideband frequency-response work, and communication-system verification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSequence, Pattern, I\/Q, and Expression Functions\u003c\/h3\u003e\n\u003cp\u003eSequence chains up to 1,024 waveforms totalling 128 Mpts per channel with internal, external, manual, and timer start events for one-time loading of multiple test cases. Pattern outputs customizable code (NRZ\/RZ\/Manchester) at TTL, CMOS, ECL, and PECL logic standards. I\/Q generation delivers baseband output at any symbol rate to 1.25 GSa\/s. Expression builds complex waveforms directly from mathematical formulas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9504T+ sequence, pattern, i\/q, and expression functions\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSequence, Pattern, I\/Q, and Expression — advanced waveform generation built in.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9504T+ built-in arbitrary editor, digital bus, and 800 mhz counter\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in arbitrary editor with PC-side editing; SPI\/I²C\/UART output; 800 MHz counter.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Arbitrary Editor, Digital Bus, and 800 MHz Counter\u003c\/h3\u003e\n\u003cp\u003eThe integrated arbitrary-waveform editor supports manual drawing, line drawing, and expression-based generation, and also runs on a PC over USB or LAN. Point-by-point output spans 8 pts to 128 Mpts with 16-bit vertical resolution. SPI, I²C, and UART digital-protocol output is built in, and a high-precision hardware frequency counter measures 100 mHz to 800 MHz with 8-digit resolution and selectable AC \/ DC \/ HF-reject coupling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UTG9504T+ envelope — four equal-performance channels, 2.5 GSa\/s, 128 Mpts per channel, THD \u0026lt; 0.07%, 15-type modulation, the full advanced-function set, and a capacitive touch UI — targets benchtop work that needs genuine multi-channel stimulus, deep arbitrary support, or wide modulation coverage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-channel embedded development\u003c\/strong\u003e — four matched channels drive clock, data, trigger, and stimulus simultaneously from one instrument, conserving bench space while keeping every channel at full performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRF and communications stimulus\u003c\/strong\u003e — 3FSK, 4FSK, BPSK, QPSK, OSK, QAM digital modulation and SUM \/ DSB-AM analog modulation drive component characterization and protocol development across the full output range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed digital and serial-link test\u003c\/strong\u003e — fast adjustable edges with 100 ps steps, PRBS PN3 to PN33, and SPI \/ I²C \/ UART protocol output for interface and jitter-tolerance work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and instrumentation testing\u003c\/strong\u003e — THD below 0.07% from DC to 20 kHz when characterizing op-amp distortion, ADC noise floors, and audio-band response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-form arbitrary playback\u003c\/strong\u003e — up to 128 Mpts per channel holds extended protocol streams, sensor-emulation traces, and complex composite waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/Q and modulated-carrier work\u003c\/strong\u003e — baseband I\/Q at any symbol rate to 1.25 GSa\/s for communication-system verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated test (ATE)\u003c\/strong\u003e — LAN\/USB remote control and instrument-manager software for synchronized multi-instrument benches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord conforming to destination country standard\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003eBNC-to-BNC cable × 4 (UT-L45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does “2.5 GSa\/s with 2× interpolation” mean in practice?\u003c\/p\u003e\n\u003cp\u003eThe DAC runs at a native rate, and a digital interpolation filter inserts estimated samples to produce a 2.5 GSa\/s effective output stream. The reconstruction filter then sees a higher-rate stream and passes more high-frequency signal content with less alias distortion, giving finer detail in the upper portion of the output range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDo all four channels run at full performance simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes. The four channels are equal-performance — each delivers the full output envelope to 20 Vpp (high-Z) independently, with no derating when multiple channels are active. Channels can also be coupled by frequency \/ amplitude \/ phase ratio or merged into composite outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat modulation, sweep, and burst envelope does the UTG9504T+ cover?\u003c\/p\u003e\n\u003cp\u003eModulation: 15 types — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM. Sweep: Linear, Logarithmic, List, Step with internal \/ external \/ manual triggers. Burst: N-cycle (1 to 1,000,000 cycles), gate, and pulse-train.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat advanced waveform functions are included?\u003c\/p\u003e\n\u003cp\u003eMulti-Pulse (2 to 30 pulses, per-pulse edge \/ high \/ gap times), Multi-Tone (2 to 8 components), Sequence (up to 1,024 waveforms, 128 Mpts per channel), Pattern (NRZ \/ RZ \/ Manchester at TTL, CMOS, ECL, PECL levels), I\/Q (baseband to 1.25 GSa\/s), and Expression (formula-defined waveforms) are all standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat digital-protocol outputs are supported?\u003c\/p\u003e\n\u003cp\u003eSPI, I²C, and UART are built in. SPI and I²C run a 1 Hz to 50 MHz clock with up to 2,048-byte data depth; UART supports custom baud rates from 1 to 1,000,000 with configurable data, stop, and parity bits — useful for driving and emulating embedded serial buses directly from the generator.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9504T+ four equal-performance channels, 20 vpp\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour independent equal-performance channels, 20 Vpp on every channel\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9504T+ channel coupling and merging\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eChannel coupling and merging — ratio-linked parameters and combined outputs\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9504T+ low-distortion output and high snr\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLow-distortion continuous-wave output with high SNR on large DC offsets\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9504T+ wide-dynamic pulse with fast, independently adjustable edges\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eWide-dynamic pulse output with fine, independently adjustable edge times\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9504T+ 15 modulation types in one instrument\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFifteen modulation types — analog and digital — with sweep and burst\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9504T+ multi-pulse and multi-tone generation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-Pulse and Multi-Tone generation for complex timing and spectral test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9504T+ sequence, pattern, i\/q, and expression functions\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAdvanced functions: Sequence, Pattern, I\/Q, and Expression-based waveforms\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9504T+ built-in arbitrary editor, digital bus, and 800 mhz counter\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in arbitrary editor, digital-bus output, and 100 mHz–800 MHz hardware counter\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax sine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax square frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, independent and equal-performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (2× interpolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit (including sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary waveform length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 pts to 128 Mpts\/CH (expandable to 256 Mpts\/CH with PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in arbitrary waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 200, non-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary file storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 GB internal for arbitrary-waveform files (.bsv\/.csv)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine, Square, Ramp, Pulse, Harmonic, Noise, PRBS, DC, Arbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM frequency offset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 μHz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 μHz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic distortion (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC to 10 MHz ≤ −65 dBc; 10–100 MHz ≤ −60 dBc; 100–150 MHz ≤ −50 dBc; 150–200 MHz ≤ −40 dBc; 200–400 MHz ≤ −30 dBc; 400–500 MHz ≤ −28 dBc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-tone frequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kHz to 400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/Q center frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mHz to 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz to 20 MHz, symmetry 0.00% to 100.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear, Logarithmic, List, Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-cycle, Gate, Pulse-train\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, Expression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital-protocol output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPI, I²C, UART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mHz to 800 MHz hardware frequency counter, AC \/ DC \/ HF-reject coupling, 8-digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mVpp to 10 Vpp (50 Ω, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (high-Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mVpp to 20 Vpp (high-Z, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.07% (0 dBm, DC to 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpurious-free dynamic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−80 dBc spurious-free dynamic range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ −130 dBc\/Hz @ 10 kHz offset (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 ps (1 Vpp, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSquare rise\/fall time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 ns (Typ., square)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum pulse width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ns (Typ.); edge step to 100 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePN3 to PN33, 1 µbps to 300 Mbps; edge 2 ns to 1 ks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 MHz ±0.1 dB; ≤ 60 MHz ±0.2 dB; ≤ 80 MHz ±0.4 dB; ≤ 500 MHz ±0.8 dB (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz, ±0.5 ppm initial accuracy (25°C); ±1 ppm aging (first year)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touch, 1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host, USB Device, LAN; 10 MHz reference in\/out; external trigger in\/out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection; overload auto-disables waveform output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VACrms (±10%), 50\/60 Hz; \u0026lt; 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 90% RH below +35°C; ≤ 60% RH +35°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361 mm × 209 mm × 106 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus; EN 61010-1, EN 61326-1 EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=124\"\u003eUTG9504T+ Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368465035515,"sku":"181300100152X","price":6999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTG9000T_-1.png?v=1792619180"},{"product_id":"usg5022v-p-22-ghz-vector-rf-signal-generator-with-mechanical-attenuator","title":"USG5022V-P 22 GHz Vector RF Signal Generator with Mechanical Attenuator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe USG5022V-P is a 22 GHz vector signal generator covering 9 kHz to 22 GHz with 0.001 Hz frequency resolution and a level range of −135 dBm to +25 dBm. Single-sideband phase noise typically \u0026lt; −122 dBc\/Hz at 1 GHz \/ 20 kHz offset, amplitude accuracy ≤0.7 dB (Typ.), and frequency switching ≤40 ms make it suitable for both bench R\u0026amp;D and automated test workflows. The USG5022V-P supports full vector modulation with a 150 MHz real-time baseband bandwidth.\u003c\/p\u003e\n\u003cp\u003eAs a vector signal generator, the USG5022V-P adds a full real-time digital modulation engine to the analog signal-source foundation. With 150 MHz of baseband bandwidth, real-time QAM\/PSK\/FSK\/ASK generation, ARB waveform-file playback, multi-carrier and multi-tone modes, and AWGN noise injection for receiver testing, the USG5022V-P addresses protocol-aware wireless R\u0026amp;D and commercial production test for 5G NR, WLAN, LTE, Bluetooth, ZigBee, and Z-Wave devices. Typical QPSK EVM is 0.4% at a 1 GHz carrier; 5G NR ACPR is typically \u0026lt; −55 dBc at a 3.8 GHz carrier. With the 22 GHz CW carrier ceiling, the USG5022V-P reaches commercial 5G NR FR2 IF stages, Wi-Fi 7 6 GHz unlicensed band test, and commercial automotive ADAS radar IF-chain stimulus.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 22 GHz CW Frequency Range\u003c\/strong\u003e — \u0026gt;5 MHz to 6 GHz in I\/Q mode; 0.001 Hz resolution across the full band.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e−135 dBm to +25 dBm Level Range\u003c\/strong\u003e — 160 dB dynamic range with 0.01 dB resolution and ≤0.7 dB amplitude accuracy typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Noise \u0026lt; −122 dBc\/Hz at 1 GHz\u003c\/strong\u003e — single-sideband phase noise typical at 20 kHz offset for sensitive vector measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Step Attenuator Standard\u003c\/strong\u003e — 0 to 110 dB range with 10 dB steps; mechanical attenuator delivers maximum absolute output power across all bands.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% at 1 GHz typical; 5G NR ACPR \u0026lt; −55 dBc at 3.8 GHz typical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150 MHz Real-Time Baseband Bandwidth\u003c\/strong\u003e — internal vector engine covers wideband modulation envelopes including Wi-Fi 6\/7 channel widths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Digital Modulation\u003c\/strong\u003e — QAM, PSK, FSK, ASK with custom filter shapes (RRC, Gaussian, user-defined) and filling settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/strong\u003e — user-defined waveform replay with carrier-aggregated and multi-tone test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time AWGN Injection\u003c\/strong\u003e — precise SNR control for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave IoT Generation\u003c\/strong\u003e — protocol-aware signal generation for IoT module test and incoming inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile-Comm Protocol Simulation\u003c\/strong\u003e — 5G NR, WLAN, LTE, Bluetooth, IoT waveform support with UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAM, FM, and ΦM Analog Modulation\u003c\/strong\u003e — internal, external, or internal + external sources alongside the digital engine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO High-Stability Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging, ≤±10 ppb temperature effects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 50 MHz Function\/Arbitrary Waveform Generator\u003c\/strong\u003e — standard waveforms, sweep, and modulation from a separate LF output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNMD 2.92 mm RF Output Connector\u003c\/strong\u003e — 50 Ω 40 GHz-capable connector for full-band cable compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-Inch Touch Screen with Signal-Flow Interface\u003c\/strong\u003e — full touch control with intuitive signal-flow-diagram interaction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLAN, USB Host, USB Device Standard\u003c\/strong\u003e — full SCPI automation via LabVIEW, Python, MATLAB, Excel; GPIB available as a factory-installed hardware option (must be ordered with the instrument).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeb Control + Device Manager\u003c\/strong\u003e — browser-based remote access plus free PC management software (V2.5.0+).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Pulse Modulation\u003c\/strong\u003e — 80 dB on-off ratio with customizable pulse trains.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Narrow-Pulse Generator\u003c\/strong\u003e — 40 ns minimum width with 10 ns resolution for radar component test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional USB Power Sensor Support (USG5000-PK)\u003c\/strong\u003e — license-activated readback and flatness correction with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE | cETLus | RoHS Compliant\u003c\/strong\u003e — meets common North American and European safety and environmental standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Features\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eHigh Spectral Purity for Sensitive Receiver and Component Test\u003c\/h3\u003e\n\u003cp\u003eSingle-sideband phase noise typically below −122 dBc\/Hz at 1 GHz with a 20 kHz offset is the headline spectral-purity figure that determines whether a generator can stimulate the device under test without contaminating the measurement. Low close-in phase noise matters for adjacent-channel rejection testing on receivers, image-rejection on mixers, and narrowband filter characterization where the stimulus must be cleaner than the device's own passband behavior. Phase noise degrades with the band multiplier (N) architecture: typically −102 dBc\/Hz at 10 GHz and −98 dBc\/Hz at 22 GHz.\u003c\/p\u003e\n\u003cp\u003eThe clock-source architecture supports ≤±0.2 ppm\/year aging rate and ≤±10 ppb temperature effects — stable enough for calibration-cycle use without external 10 MHz lock. Rear-panel 10 MHz reference input and output are available for multi-instrument synchronization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG5000-series RF generator\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-phase_noise.jpg\" alt=\"Phase noise measurement plot for USG5000-series RF generator\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eSingle-sideband phase noise typical \u0026lt; -122 dBc\/Hz at 1 GHz\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-vector_modulation.gif\" alt=\"USG5000V vector modulation display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-vector_modulation.gif\" alt=\"USG5000V vector modulation display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eQPSK EVM 0.4% at 1 GHz, 5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz (Typ.)\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eReal-Time Vector Modulation with 150 MHz Baseband Bandwidth\u003c\/h3\u003e\n\u003cp\u003eThe internal vector engine provides 150 MHz of real-time baseband bandwidth and generates real-time QAM, PSK, FSK, and ASK modulation with configurable filter shapes (RRC, Gaussian, custom) and user-defined custom modulation types with adjustable filling settings. With QPSK at a 1 GHz carrier, measured EVM is 0.4% typical — calibration-grade. For 5G NR at 3.8 GHz, ACPR is \u0026lt; −55 dBc typical, so the instrument's own spectral regrowth doesn't dominate measurements on 5G receiver and transmitter validation work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V_2.png\" alt=\"USG5000V front panel showing level control\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e160 dB output range with three ALC modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V_2.png\" alt=\"USG5000V front panel showing level control\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e160 dB output range with three ALC modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide Output Range — +25 dBm Maximum, −135 dBm Minimum\u003c\/h3\u003e\n\u003cp\u003eOutput settable range is −135 dBm to +25 dBm with 0.01 dB resolution. Maximum output power varies by frequency band and attenuator type; the mechanical attenuator on this variant covers 0 to 110 dB in 10 dB steps.\u003c\/p\u003e\n\u003cp\u003eThree ALC (Automatic Level Control) modes are available: ALC Auto selects the optimum mode for the current operating state; ALC On runs closed-loop level control for CW, FM, and ΦM operation; ALC S\u0026amp;H (Off) freezes the closed-loop value on frequency or amplitude transitions, useful for AM and pulse modulation work where ALC interaction with the modulation envelope is undesirable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-scanning_methods.gif\" alt=\"USG5000V ARB and multi-carrier mode displays\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-scanning_methods.gif\" alt=\"USG5000V ARB and multi-carrier mode displays\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eARB playback with multi-carrier and multi-tone modes\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eARB Playback, Multi-Carrier, and Multi-Tone Modes\u003c\/h3\u003e\n\u003cp\u003eARB playback mode plays back user-defined arbitrary waveform data at variable sampling rates with baseband preview in both time and frequency domains. ARB multi-carrier mode splits wideband signals into multiple narrowband subcarriers, each independently modulated — simplifying carrier-aggregated LTE\/5G NR signals and multi-channel interference environments without external combiners. Multi-tone mode generates multiple frequency components simultaneously for intermodulation distortion testing and multi-channel receiver characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eReal-Time AWGN Injection for Receiver Sensitivity Testing\u003c\/h3\u003e\n\u003cp\u003eThe instrument provides pure-noise output and real-time additive white Gaussian noise injection with precise signal-to-noise power control — no separate noise measurement step required before each test. For receiver sensitivity verification, blocking and selectivity testing, and dynamic-range characterization, AWGN injection is the workhorse stimulus. Controlling SNR digitally inside the same instrument that generates the modulated signal removes a measurement-uncertainty drift source on long-running production sequences.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-AWGN_white_guassian_noise.gif\" alt=\"USG5000V AWGN spectrum display\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-AWGN_white_guassian_noise.gif\" alt=\"USG5000V AWGN spectrum display\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eReal-time AWGN injection with precise SNR control\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-signal_studio_support.gif\" alt=\"USG5000V SignalStudio software upper-computer interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-signal_studio_support.gif\" alt=\"USG5000V SignalStudio software upper-computer interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNative ZigBee, Z-Wave + 5G NR\/WLAN\/LTE\/Bluetooth via SignalStudio\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eIoT and Mobile Communication Protocol Generation\u003c\/h3\u003e\n\u003cp\u003eNative ZigBee and Z-Wave signal generation is built into the instrument's vector engine with flexible modulation parameter settings per protocol — eliminating third-party IoT signal source dependencies for incoming inspection, R\u0026amp;D prototyping, and production-line stimulus. For 5G NR, WLAN, LTE, and Bluetooth waveforms, the instrument pairs with UNI-T's SignalStudio software (sold separately) for protocol-compliant signal simulation across commercial wireless-device R\u0026amp;D and compliance pre-screen.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eOptional Pulse and Narrow-Pulse Generation\u003c\/h3\u003e\n\u003cp\u003eThe optional pulse modulation package adds an on-off ratio of up to 80 dB with customizable pulse-train definitions, enabling single-instrument pulsed RF for radar component test, time-gated stimulus, and EMC pulsed-emission work. The narrow-pulse generator option extends capability to a 40 ns minimum width with 10 ns resolution, addressing test requirements of millimeter-wave radar components used in commercial automotive ADAS suppliers and short-range industrial radar systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG5000V pulse modulation output waveform\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG3000M-USG5000M_pulse.png\" alt=\"USG5000V pulse modulation output waveform\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003ePulse modulation with 80 dB on-off ratio and narrow-pulse generation\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eUSB Power Sensor Support — Flatness Correction at the DUT Plane (Option USG5000-PK)\u003c\/h3\u003e\n\u003cp\u003eThe optional \u003cstrong\u003eUSG5000-PK\u003c\/strong\u003e software license enables the instrument to read and display power measurements from a user-supplied USB power sensor connected to the front-panel USB Host port. The license is delivered as a file that installs from a USB stick via the instrument's Option Install menu, following the same activation workflow as the Pulse Modulation and GPIB options. A USB power sensor is not included; the user supplies a compatible sensor.\u003c\/p\u003e\n\u003cp\u003eOnce activated, the Power Sensor menu provides measurement frequency entry, frequency coupling to the current RF carrier (with multiplier and offset for harmonic and IF-shifted measurements), measurement averaging, and amplitude offset entry — the standard tools for flatness correction and cable-loss compensation at the DUT plane. The amplitude offset entry is particularly useful when the signal path between the generator and the device under test includes cables, attenuators, or amplifiers: the displayed power reflects what the DUT actually sees, not what leaves the generator's output connector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-power_de-embedding.jpg\" alt=\"USG5000V USB power sensor measurement and path-loss compensation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-power_de-embedding.jpg\" alt=\"USG5000V USB power sensor measurement and path-loss compensation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLicense-activated USB power sensor support — user supplies sensor\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e5-Inch Touch UI with Signal-Flow Interface\u003c\/h3\u003e\n\u003cp\u003eA 5.0-inch high-resolution touch screen provides full touch control over every function except the power switch. The interface is built around a signal-flow diagram — the user sees modulation source, modulation type, sweep mode, and RF carrier as a connected chain rather than as scattered menu items. For an instrument with this much configurable surface area (multiple modulation paths, multiple sweep modes, multiple digital protocols, ARB and multi-carrier work, optional pulse and power-sensor options), the signal-flow paradigm meaningfully cuts setup time on R\u0026amp;D benches where the test configuration changes hour-to-hour.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-flat_interface.gif\" alt=\"USG5000V touch UI with flat signal-flow interface\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-flat_interface.gif\" alt=\"USG5000V touch UI with flat signal-flow interface\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e5-inch touch screen with signal-flow-guided interface\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-computer_interface.gif\" alt=\"USG5000V computer interface and automation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/USG5000V-computer_interface.gif\" alt=\"USG5000V computer interface and automation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLAN, USB, GPIB (factory option) with SCPI, Web Control, and Device Manager\u003c\/span\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eFull Automation — SCPI, Web Control, Device Manager\u003c\/h3\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option and must be ordered with the instrument. All ports speak the standard SCPI command set, enabling remote operation from any automation-capable host. Test engineers commonly drive the instrument from LabVIEW, Python, MATLAB, or even Excel macros for batch command execution.\u003c\/p\u003e\n\u003cp\u003eWeb Control provides browser-based remote access — point a PC or mobile browser at the instrument's IP address and the full front-panel UI is available remotely, with no client install. Device Manager (UNI-T's free PC software, V2.5.0 and higher) manages the instrument via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB, and handles batch instrument inventories on a multi-station test floor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"product-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (CW mode)\u003c\/th\u003e\n\u003ctd\u003e9 kHz to 22 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency range (I\/Q mode)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 6 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase offset step\u003c\/th\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency switching speed\u003c\/th\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel settable range\u003c\/th\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLevel resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmplitude accuracy (Typ.)\u003c\/th\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAttenuator type\u003c\/th\u003e\n\u003ctd\u003eMechanical step attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase noise (Typ., 20 kHz offset)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOscillator aging rate\u003c\/th\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature effects\u003c\/th\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInitial calibration accuracy\u003c\/th\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog modulation\u003c\/th\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital modulation\u003c\/th\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBaseband bandwidth\u003c\/th\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVector modulation EVM (Typ.)\u003c\/th\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e5G NR ACPR (Typ.)\u003c\/th\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eARB modes\u003c\/th\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise injection\u003c\/th\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIoT protocols (native)\u003c\/th\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMobile-comm protocol simulation\u003c\/th\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse modulation (option)\u003c\/th\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNarrow pulse (option)\u003c\/th\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB power sensor (option USG5000-PK)\u003c\/th\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSweep modes\u003c\/th\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStep sweep points\u003c\/th\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eList sweep points\u003c\/th\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDwell time\u003c\/th\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuilt-in AWG\u003c\/th\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReference (10 MHz)\u003c\/th\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRF output connector\u003c\/th\u003e\n\u003ctd\u003eNMD 2.92 (50 Ω) — supports DC to 40 GHz with 2.92 mm-compatible cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard interfaces\u003c\/th\u003e\n\u003ctd\u003eLAN, USB Host, USB Device (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemote control\u003c\/th\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRoHS\u003c\/th\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice. \"Typ.\" values represent typical performance and are not warranted.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eProtocol-Aware Wireless Device Development\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlagship 22 GHz Wireless and IF-Stage R\u0026amp;D\u003c\/strong\u003e — 22 GHz CW coverage with full vector modulation in the I\/Q band (\u0026gt;5 MHz to 6 GHz) — addresses 5G NR FR2 IF stages, Wi-Fi 7 6 GHz unlicensed band, and commercial automotive radar IF chains with mechanical-attenuator output headroom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQAM, PSK, FSK, ASK Real-Time Digital Modulation\u003c\/strong\u003e — Custom filter shapes (RRC, Gaussian, user-defined) for protocol-specific test signal generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eARB Multi-Carrier Mode\u003c\/strong\u003e — Carrier-aggregated LTE \/ 5G NR test signals without external combiners.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAWGN Injection\u003c\/strong\u003e — Real-time noise injection for receiver sensitivity and dynamic-range characterization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial Production Test and Calibration Labs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e22 GHz Cal Lab and Spec Verification\u003c\/strong\u003e — Mechanical attenuator and 22 GHz CW range with full vector modulation in the baseband band — covers vector signal analyzer and signal generator commercial calibration work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration-Grade Vector Modulation Accuracy\u003c\/strong\u003e — QPSK EVM 0.4% typical at 1 GHz supports commercial cal-lab spec verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Power Sensor Integration\u003c\/strong\u003e — Optional USG5000-PK license activates flatness correction at the DUT plane with a user-supplied USB power sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOCXO Clock Source Standard\u003c\/strong\u003e — ≤±0.2 ppm\/year aging suits calibration-cycle scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIoT Device R\u0026amp;D and Compliance Pre-Screen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlagship IoT and Industrial Wireless Test\u003c\/strong\u003e — 22 GHz coverage with mechanical attenuator, vector modulation, AWGN injection, and built-in IoT protocol generation in one chassis — suited to next-generation industrial wireless and commercial compliance pre-screen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative ZigBee and Z-Wave Generation\u003c\/strong\u003e — Flexible modulation parameter control (modulation count, modulation method) per protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio Protocol Simulation\u003c\/strong\u003e — 5G NR \/ WLAN \/ LTE \/ Bluetooth waveform support via UNI-T SignalStudio software (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Tone Mode\u003c\/strong\u003e — IoT mesh-network coexistence and interference testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5022V-P RF signal generator\u003c\/li\u003e\n\u003cli\u003eAC power cord (region-specific)\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003eQuick start guide and certificate of conformity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG5000-PM\u003c\/strong\u003e — Pulse modulation option (license-activated; 80 dB on-off ratio, customizable pulse trains).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG5000-PG\u003c\/strong\u003e — Narrow-pulse generator option (license-activated; 40 ns minimum width, 10 ns resolution).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG5000-PK\u003c\/strong\u003e — USB power sensor support option (license-activated; user supplies a compatible USB power sensor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSG5000-GPIB\u003c\/strong\u003e — GPIB interface hardware option; adds a factory-installed IEEE 488 port for legacy automation systems. Must be ordered with the instrument — cannot be added after purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignalStudio + waveform licenses\u003c\/strong\u003e — UNI-T SignalStudio software (sold separately) with optional waveform-playback license packages: BT (Bluetooth), OFDM (custom OFDM), DM (custom digital modulation), VIOT (extended IoT).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.92 mm cables and adapters\u003c\/strong\u003e — UT-W03-40GHz-2.92J RF cable, UT-C04-40GHz 2.92-KKG connector, UT-CK02 (2 × UT-C04-40GHz 2.92-KKG connectors), UT-C03-18GHz RF adapter SMA-N.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\nUSG5014M — 14 GHz analog, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG5014M-P — 14 GHz analog, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG5022M-P — 22 GHz analog flagship, mechanical attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG5014V — 14 GHz vector, electronic attenuator.\u003c\/li\u003e\n\u003cli\u003e\nUSG5014V-P — 14 GHz vector, mechanical attenuator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the V-series and the M-series?\u003c\/p\u003e\n\u003cp\u003eThe M-series is an analog RF signal generator (AM, FM, ΦM with optional pulse and narrow-pulse modulation) suited to amplifier and filter R\u0026amp;D, receiver calibration, and pulsed-RF component test. The V-series adds a full real-time digital modulation engine on the same analog foundation: 150 MHz baseband bandwidth, QAM\/PSK\/FSK\/ASK, ARB playback with multi-carrier, AWGN injection, and native ZigBee\/Z-Wave IoT generation. SignalStudio software (sold separately) extends V-series coverage to 5G NR\/WLAN\/LTE\/Bluetooth. M addresses component-level stimulus; V addresses protocol-aware wireless device development.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs there a non-−P 22 GHz variant of the USG5022V-P?\u003c\/p\u003e\n\u003cp\u003eNo. At 22 GHz the USG5022V-P is offered only with the mechanical step attenuator standard — UNI-T does not produce an electronic-attenuator 22 GHz variant. The mechanical attenuator delivers maximum absolute output power across the full 22 GHz band, the typical requirement for Ku-band and K-band component and receiver test. For high-cycle automation at lower bands, the 14 GHz USG5014V with electronic attenuator standard or the USG5014V-P with mechanical attenuator are the options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat automation interfaces are standard?\u003c\/p\u003e\n\u003cp\u003eLAN, USB Host, and USB Device are standard rear-panel interfaces. GPIB is available as a factory-installed hardware option (must be ordered with the instrument). All ports support the standard SCPI command set, so the instrument drops into any existing automated test station (LabVIEW, Python, MATLAB, Excel) without protocol translation. Web Control provides browser-based remote access via the instrument's IP address — no client install required, works from PC and mobile. UNI-T's free Device Manager PC software (V2.5.0 and higher) handles batch instrument inventories via LAN (VXI-11, Socket), USB Device (USB-TMC), or GPIB.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does the USG5000-PK power sensor option provide?\u003c\/p\u003e\n\u003cp\u003eUSG5000-PK is a software license that activates USB power sensor support. The user connects a compatible USB-TMC power sensor (sold separately) to the front-panel USB Host port; the instrument displays power measurements on its own screen with menu controls for measurement frequency, frequency coupling (multiplier + offset), amplitude offset for path-loss compensation, and averaging. The primary use case is flatness correction and cable-loss compensation at the DUT plane. License is activated via UNI-T's standard option-install workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (CW mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 22 GHz (CW mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range (I\/Q mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 6 GHz (I\/Q mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase offset step\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency switching speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤40 ms (SCPI \/ list \/ step sweep)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel settable range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +25 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLevel resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤0.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuator type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMechanical step attenuator standard (0 to 110 dB, 10 dB steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (Typ., 20 kHz offset)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOscillator aging rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.2 ppm\/year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature effects\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±10 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial calibration accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ ±40 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (internal \/ external \/ internal+external)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital modulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQAM, PSK, FSK, ASK (real-time digital standard formats; custom modulation supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseband bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 MHz real-time baseband bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVector modulation EVM (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQPSK EVM 0.4% at 1 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5G NR ACPR (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR ACPR \u0026lt;-55 dBc at 3.8 GHz carrier (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARB modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eARB playback, ARB multi-carrier, multi-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWGN (additive white Gaussian noise) for receiver testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIoT protocols (native)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZigBee, Z-Wave (IoT signal generation and playback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile-comm protocol simulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5G NR, WLAN, LTE, Bluetooth, IoT (with SignalStudio software, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse modulation (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB on-off ratio, customizable pulse trains\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNarrow pulse (option)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin width \/ resolution: 40 ns \/ 10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB power sensor (option USG5000-PK)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLicense-activated; flatness correction with user-supplied USB power sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStep sweep, list sweep (frequency, amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStep sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 65535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList sweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDwell time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 μs to 100 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MHz function \/ arbitrary waveform generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference (10 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz (in\/out, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRF output connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 (50 Ω) — supports DC to 40 GHz with 2.92 mm-compatible cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0-inch touch screen, signal-flow-guided interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLAN, USB Host, USB Device (GPIB optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCPI, Web Control (browser), Device Manager (PC software, V2.5.0+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE | cETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=120\"\u003eUSG5022V-P Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUSG5000-GPIB — GPIB Adapter Option\u003c\/li\u003e\n  \u003cli\u003eUSG5000-PG — Narrow Pulse Generator Option\u003c\/li\u003e\n  \u003cli\u003eUSG5000-PK — Power Meter Option\u003c\/li\u003e\n  \u003cli\u003eUSG5000-PM — Pulse Modulation Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368465363195,"sku":"181300200035X","price":29999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/USG5000V_1_sq.jpg?v=1792619197"},{"product_id":"utg4254x-250-mhz-4ch-performance-series-arbitrary-waveform-generator","title":"UTG4254X 250 MHz 4Ch Performance-Series Arbitrary Waveform Generator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTG4254X\u003c\/strong\u003e is a four-channel arbitrary waveform generator with a maximum sine output of 250 MHz, built around a 16-bit DAC and a 2.5 GSa\/s sample rate (2× interpolation). All four channels deliver equal performance with full 20 Vpp output (high-Z), and an 8 pts to 128 Mpts per-channel arbitrary memory supports long-form custom stimulus. A 10.1-inch capacitive touch display replaces menu-driven navigation with direct parameter manipulation.\u003c\/p\u003e\n\u003cp\u003e100 MHz square \/ pulse output, 1 µHz frequency resolution across the full 250 MHz range, harmonic distortion below 0.07% (DC to 20 kHz), and an 800 MHz hardware frequency counter. Fifteen analog and digital modulation types — including 3FSK, 4FSK, QAM, and the full BPSK \/ QPSK \/ OSK set. Linear, logarithmic, list, and step sweep. Three burst modes (N-cycle, gate, infinite). Advanced Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression functions. Over 200 built-in arbitrary waveforms with SPI \/ I²C \/ UART digital-protocol output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eChoosing Your Model — UTG4000X Performance-Series\u003c\/h2\u003e\n\u003cp\u003eThree four-channel models share one chassis, the same 2.5 GSa\/s sample rate, 16-bit DAC, 128 Mpts per-channel memory, full 15-type modulation set, every advanced function, and the same interface and display. They differ in one axis only: maximum output frequency.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTG4104X\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz sine \/ 50 MHz square \u0026amp; pulse — the choice for general embedded, instrumentation, and teaching-lab work within a 100 MHz envelope.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTG4164X\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 MHz sine \/ 80 MHz square \u0026amp; pulse — added headroom for higher-frequency stimulus and wider modulation carriers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUTG4254X\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz sine \/ 100 MHz square \u0026amp; pulse — the widest output envelope in the series for the most demanding signal-frequency requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eThis page describes the \u003cstrong\u003eUTG4254X\u003c\/strong\u003e. Channel architecture, modulation, advanced functions, interfaces, and protection below apply to all three models; the Specifications table lists this model's frequency figures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 MHz sine \/ 100 MHz square \u0026amp; pulse\u003c\/strong\u003e — four-channel output with 1 µHz frequency resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour equal-performance channels, 20 Vpp\u003c\/strong\u003e — every channel delivers the full output envelope; independent or combined operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s sample rate, 16-bit DAC\u003c\/strong\u003e — with 2× interpolation; 8 pts to 128 Mpts per-channel arbitrary memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic distortion below 0.07%\u003c\/strong\u003e — low distortion with −80 dBc spurious-free dynamic range and high SNR on large DC offsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 modulation types\u003c\/strong\u003e — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM — analog and digital in one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e — Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression-based waveform generation built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-dynamic pulse, fast edges\u003c\/strong\u003e — 100 ps edge-time adjustment, 2.4 ns minimum pulse width, per-pulse edge control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800 MHz hardware frequency counter\u003c\/strong\u003e — 100 mHz to 800 MHz, 8-digit, AC \/ DC \/ HF-reject coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 200 built-in arbitrary waveforms\u003c\/strong\u003e — plus SPI, I²C, and UART digital-protocol output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touch display\u003c\/strong\u003e — 1280 × 800; direct parameter manipulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Host\/Device, LAN, HDMI\u003c\/strong\u003e — with 10 MHz reference in\/out and external trigger; full remote-control integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTG4254X Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFour Equal-Performance Channels, 20 Vpp\u003c\/h3\u003e\n\u003cp\u003eFour independent channels, every one delivering identical performance — there is no reduced second-bank or derated upper channels. Each channel produces the full output envelope to 20 Vpp (high-Z), and channels can be configured independently or combined: CH2 can mirror CH1, or CH1 = CH1 + CH2 + CH3 + CH4. Four matched channels drive clock, data, trigger, and stimulus simultaneously from a single instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_four-channel_output.png\" alt=\"UTG4254X four equal-performance channels, 20 vpp\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour equivalent-performance channels with full 20 Vpp output — no derating on any channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_channel_coupling_merge.png\" alt=\"UTG4254X channel coupling and merging\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFrequency, amplitude, and phase coupling across channels; outputs merge into composite signals.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eChannel Coupling and Merging\u003c\/h3\u003e\n\u003cp\u003eChannels can be freely coupled with configurable frequency, amplitude, and phase relationships (coupling ratio 0.0001 to 10,000), so a parameter change on one channel propagates to its coupled partners by a defined ratio and offset. Outputs can also be merged into arbitrary combinations, producing summed, differential, and composite signals from a single instrument without external combiners.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLow-Distortion Output and High SNR\u003c\/h3\u003e\n\u003cp\u003eDigital sampling produces sine, square, ramp, pulse, arbitrary, harmonic, noise, DC, and PRBS waveforms with low distortion and low jitter. Total harmonic distortion is below 0.07% from DC to 20 kHz, with a spurious-free dynamic range to −80 dBc. A small signal superimposed on a large DC offset retains a high signal-to-noise ratio, which matters when the stimulus must be quieter than the device under test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_low_distortion_output.png\" alt=\"UTG4254X low-distortion output and high snr\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTHD below 0.07% (DC to 20 kHz) with −80 dBc spurious-free dynamic range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_pulse_wave.png\" alt=\"UTG4254X wide-dynamic pulse with fast, independently adjustable edges\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEdge time adjustable in 100 ps steps; 2.4 ns minimum pulse width; per-pulse edge control.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide-Dynamic Pulse with Fast, Independently Adjustable Edges\u003c\/h3\u003e\n\u003cp\u003eThe pulse generator offers high-precision adjustable edge times with increments as fine as 100 ps and a minimum pulse width of 2.4 ns (Typ.), generating high harmonic content comparable to a dedicated pulse generator. Edge time can be set independently for each pulse, down to a minimum of 2 ns. Square and pulse jitter stays low across the operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Modulation Types in One Instrument\u003c\/h3\u003e\n\u003cp\u003eFifteen analog and digital modulation schemes are built in: AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, and PWM. QAM supports constellations from QAM4 to QAM256. Each channel supports independent or simultaneous internal\/external modulation and internal\/external\/manual triggering, alongside Linear\/Logarithmic\/List\/Step frequency sweep and N-cycle\/gate\/infinite burst.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_modulation_types.png\" alt=\"UTG4254X 15 modulation types in one instrument\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFifteen modulation types covering analog and digital schemes, plus sweep and burst.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_multi_pulse.png\" alt=\"UTG4254X multi-pulse and multi-tone generation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-Pulse: 2–30 pulses with per-pulse edge\/width control. Multi-Tone: 2–8 components.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eMulti-Pulse and Multi-Tone Generation\u003c\/h3\u003e\n\u003cp\u003eMulti-Pulse produces pulse trains of 2 to 30 pulses with independently adjustable edge times and pulse widths for rapid, precise multi-pulse testing without custom code. Multi-Tone synthesizes 2 to 8 simultaneous frequency components across the full output range, reproducing real-world multi-frequency signals for nonlinear-distortion analysis, wideband frequency-response work, and communication-system verification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSequence, Pattern, I\/Q, and Expression Functions\u003c\/h3\u003e\n\u003cp\u003eSequence chains up to 1,024 waveforms totalling 128 Mpts with continuous, cyclic, and gated modes for one-time loading of multiple test cases. Pattern outputs customizable code (NRZ\/RZ\/Manchester) at multiple logic standards. I\/Q generation with the SignalStudio PC software delivers high-EVM baseband output at any symbol rate. Expression builds complex waveforms directly from mathematical formulas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_sequence_dynamic_testing_008a8d1a-34bb-438f-871a-00cb640288f0.png\" alt=\"UTG4254X sequence, pattern, i\/q, and expression functions\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSequence, Pattern, I\/Q, and Expression — advanced waveform generation built in.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_edit_arb_1.png\" alt=\"UTG4254X built-in arbitrary editor and 800 mhz frequency counter\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in arbitrary editor with PC-side editing; 800 MHz hardware frequency counter.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Arbitrary Editor and 800 MHz Frequency Counter\u003c\/h3\u003e\n\u003cp\u003eThe integrated arbitrary-waveform editor supports manual drawing, line drawing, and expression-based generation with real-time playback, and also runs on a PC over USB or LAN. Point-by-point output spans 8 pts to 128 Mpts with 16-bit vertical resolution. A high-precision hardware frequency counter measures 100 mHz to 800 MHz with 8-digit resolution and selectable AC \/ DC \/ high-frequency-reject coupling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe Performance-Series envelope — four equal-performance channels, 2.5 GSa\/s, 128 Mpts per channel, THD \u0026lt; 0.07%, 15-type modulation, the full advanced-function set, and a capacitive touch UI — targets benchtop work that needs genuine multi-channel stimulus, deep arbitrary support, or wide modulation coverage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-channel embedded development\u003c\/strong\u003e — four matched channels drive clock, data, trigger, and stimulus simultaneously from one instrument, conserving bench space and keeping every channel at full performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunications-stimulus development\u003c\/strong\u003e — 3FSK, 4FSK, BPSK, QPSK, OSK, QAM digital modulation; SUM and DSB-AM analog modulation; configurable hop rate and depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and instrumentation testing\u003c\/strong\u003e — THD below 0.07% from DC to 20 kHz when characterizing op-amp distortion, ADC noise floors, and audio-band response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed digital input stimulus\u003c\/strong\u003e — fast adjustable edges, 100 ps edge steps, and 2.4 ns minimum pulse width for edge-rate-sensitivity characterization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-form arbitrary playback\u003c\/strong\u003e — up to 128 Mpts per channel holds extended protocol streams, sensor-emulation traces, and complex composite waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/Q and modulated-carrier work\u003c\/strong\u003e — SignalStudio-driven I\/Q baseband with high EVM at any symbol rate for communication-system verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated test (ATE)\u003c\/strong\u003e — LAN\/USB remote control and instrument-manager software for synchronized multi-instrument benches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories and Family Options\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord conforming to destination country standard\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003eBNC-to-BNC cable × 4 (UT-L45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFamily Members\u003c\/h3\u003e\n\u003cp\u003eThe UTG4000X Performance-Series consists of three four-channel SKUs sharing the same chassis, sample rate, DAC, modulation set, advanced functions, and arbitrary-waveform memory depth:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG4104X\u003c\/strong\u003e — 100 MHz sine \/ 50 MHz square\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG4164X\u003c\/strong\u003e — 160 MHz sine \/ 80 MHz square\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTG4254X\u003c\/strong\u003e — 250 MHz sine \/ 100 MHz square (this product)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does “2.5 GSa\/s with 2× interpolation” mean in practice?\u003c\/p\u003e\n\u003cp\u003eThe DAC runs at a native rate, and a digital interpolation filter inserts estimated samples to produce a 2.5 GSa\/s effective output stream. The reconstruction filter then sees a higher-rate stream and passes more high-frequency signal content with less alias distortion, giving finer detail in the upper portion of the output range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat is the difference between the UTG4254X and the other UTG4000X models?\u003c\/p\u003e\n\u003cp\u003eAll three UTG4000X models are the same four-channel instrument with the same sample rate, DAC, memory, modulation set, advanced functions, interfaces, and chassis. They differ only in maximum output frequency: 100 MHz (UTG4104X), 160 MHz (UTG4164X), and 250 MHz (UTG4254X) sine, with correspondingly scaled square\/pulse and modulation ranges. Choose by the highest output frequency your work requires.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDo all four channels run at full performance simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes. The four channels are equal-performance — each delivers the full output envelope to 20 Vpp (high-Z) independently, with no derating when multiple channels are active. Channels can also be coupled by frequency\/amplitude\/phase ratio or merged into composite outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat modulation, sweep, and burst envelope does the UTG4000X cover?\u003c\/p\u003e\n\u003cp\u003eModulation: 15 types — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM, with QAM4 through QAM256 constellations. Sweep: Linear, Logarithmic, List, Step with internal\/external\/manual triggers. Burst: N-cycle (1 to 1,000,000 cycles), gate, and infinite.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat advanced waveform functions are included?\u003c\/p\u003e\n\u003cp\u003eMulti-Pulse (2 to 30 pulses, per-pulse edge\/width), Multi-Tone (2 to 8 components), Sequence (up to 1,024 waveforms, 128 Mpts total), Pattern (NRZ\/RZ\/Manchester at multiple logic standards), I\/Q (SignalStudio baseband), and Expression (formula-defined waveforms) are all standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_four-channel_output.png\" alt=\"UTG4254X four equal-performance channels, 20 vpp\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour independent equal-performance channels, 20 Vpp on every channel\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_channel_coupling_merge.png\" alt=\"UTG4254X channel coupling and merging\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eChannel coupling and merging — ratio-linked parameters and combined outputs\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_low_distortion_output.png\" alt=\"UTG4254X low-distortion output and high snr\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLow-distortion continuous-wave output with high SNR on large DC offsets\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_pulse_wave.png\" alt=\"UTG4254X wide-dynamic pulse with fast, independently adjustable edges\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eWide-dynamic pulse output with fine, independently adjustable edge times\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_modulation_types.png\" alt=\"UTG4254X 15 modulation types in one instrument\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFifteen modulation types — analog and digital — with sweep and burst\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_multi_pulse.png\" alt=\"UTG4254X multi-pulse and multi-tone generation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-Pulse and Multi-Tone generation for complex timing and spectral test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_sequence_dynamic_testing_008a8d1a-34bb-438f-871a-00cb640288f0.png\" alt=\"UTG4254X sequence, pattern, i\/q, and expression functions\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAdvanced functions: Sequence, Pattern, I\/Q, and Expression-based waveforms\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG4000X_edit_arb_1.png\" alt=\"UTG4254X built-in arbitrary editor and 800 mhz frequency counter\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in arbitrary-waveform editor and 100 mHz–800 MHz hardware counter\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax sine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax square \/ pulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, independent and equal-performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (2× interpolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit (including sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary waveform length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 pts to 128 Mpts\/CH (expandable to 256 Mpts\/CH with PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in arbitrary waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 200, non-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary file storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 GB internal for arbitrary-waveform files (.bsv\/.csv)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine, Square, Ramp, Pulse, Harmonic, Noise, PRBS, DC, Arbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM frequency offset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 μHz to 125 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 μHz to 125 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-tone frequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kHz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/Q center frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear, Logarithmic, List, Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-cycle, Gate, Infinite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, Expression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital-protocol output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPI, I²C, UART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mHz to 800 MHz hardware frequency counter, AC \/ DC \/ HF-reject coupling, 8-digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mVpp to 10 Vpp (50 Ω, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (high-Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mVpp to 20 Vpp (high-Z, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.07% (0 dBm, DC to 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ −130 dBc\/Hz @ 10 kHz offset (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse\/arb jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ps (1 Vpp, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise\/fall time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 ns (Typ., square\/pulse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum pulse width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 ns (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePN3 to PN33, 1 µbps to 300 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 MHz ±0.1 dB; ≤ 60 MHz ±0.2 dB; ≤ 80 MHz ±0.4 dB; ≤ 250 MHz ±0.8 dB (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touch, 1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host, USB Device, LAN, HDMI; 10 MHz reference in\/out; external trigger in\/out; external modulation input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection; overload auto-disables waveform output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VACrms (±10%), 50\/60 Hz; \u0026lt; 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361 mm × 209 mm × 106 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=125\"\u003eUTG4254X Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368465527035,"sku":"181300100150X","price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTG4000X-1.png?v=1792619211"},{"product_id":"uts5000a-vsa-digital-demodulation-analysis-option","title":"UTS5000A-VSA Digital Demodulation Analysis Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UTS5000A-VSA adds digital modulation analysis — EVM, constellation diagrams, and quality metrics for wireless and communications testing. The option is enabled by a software license keyed to the spectrum analyzer's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Demodulation\u003c\/strong\u003e — ASK, FSK, PSK, QAM, OFDM with EVM and quality measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstellation Diagram\u003c\/strong\u003e — Visual assessment of modulation quality and impairments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEVM Measurement\u003c\/strong\u003e — Error Vector Magnitude — the standard modulation quality metric.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Transmitter\u003c\/strong\u003e — Measure EVM and constellation for modulation quality verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Quality\u003c\/strong\u003e — Evaluate modulation quality of custom digital communication signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all UTS5000A Series spectrum analyzers. The same capability is offered on other UNI-T spectrum analyzer families: UTS3000A, UTS7000A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the spectrum analyzer's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the spectrum analyzer from a USB drive through the option-install menu. Refer to the spectrum analyzer's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368466673915,"sku":"191500400003","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS5000A-VSA_d81cdf2b-634a-4377-8b89-5c0481aadd8c.png?v=1792619300"},{"product_id":"uts5000a-i-q-i-q-analyzer-option","title":"UTS5000A-I\/Q I\/Q Analyzer Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UTS5000A-I\/Q adds I\/Q signal analysis for modulated signals — capture, visualize, and export I\/Q data. The option is enabled by a software license keyed to the spectrum analyzer's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/Q Capture\u003c\/strong\u003e — Raw I\/Q data capture and processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Domain\u003c\/strong\u003e — Time and frequency views simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport\u003c\/strong\u003e — Export I\/Q data for external analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustom Analysis\u003c\/strong\u003e — Capture I\/Q from proprietary signals for external demod.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Recording\u003c\/strong\u003e — Record I\/Q for playback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all UTS5000A Series spectrum analyzers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the spectrum analyzer's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the spectrum analyzer from a USB drive through the option-install menu. Refer to the spectrum analyzer's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368466641147,"sku":"191503100001","price":1199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS5000A-IQ_856bc070-772b-4e47-9a04-7c8b32da84b6.png?v=1792619300"},{"product_id":"utg9354t-350-mhz-4ch-elite-series-arbitrary-waveform-generator","title":"UTG9354T+ 350 MHz 4Ch Elite-Series Arbitrary Waveform Generator","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTG9354T+\u003c\/strong\u003e is a four-channel arbitrary waveform generator with a maximum sine output of 350 MHz, built around a 16-bit DAC and a 2.5 GSa\/s sample rate (2× interpolation). All four channels deliver equal performance with full 20 Vpp output (high-Z), and an 8 pts to 128 Mpts per-channel arbitrary memory supports long-form custom stimulus. A 10.1-inch capacitive touch display replaces menu-driven navigation with direct parameter manipulation.\u003c\/p\u003e\n\u003cp\u003e120 MHz square and 120 MHz pulse output, 1 µHz frequency resolution across the full 350 MHz range, harmonic distortion below 0.07% (DC to 20 kHz), and an 800 MHz hardware frequency counter. Fifteen analog and digital modulation types — including 3FSK, 4FSK, QAM, and the full BPSK \/ QPSK \/ OSK set. Linear, logarithmic, list, and step sweep. Three burst modes. Advanced Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression functions. Over 200 built-in arbitrary waveforms with SPI \/ I²C \/ UART digital-protocol output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e350 MHz sine \/ 120 MHz square \/ 120 MHz pulse\u003c\/strong\u003e — four-channel output with 1 µHz frequency resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour equal-performance channels, 20 Vpp\u003c\/strong\u003e — every channel delivers the full output envelope; independent or combined operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 GSa\/s sample rate, 16-bit DAC\u003c\/strong\u003e — with 2× interpolation; 8 pts to 128 Mpts per-channel arbitrary memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonic distortion below 0.07%\u003c\/strong\u003e — low distortion with −80 dBc spurious-free dynamic range and high SNR on large DC offsets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15 modulation types\u003c\/strong\u003e — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM — analog and digital in one instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e — Multi-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, and Expression-based waveform generation built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide-dynamic pulse, fast edges\u003c\/strong\u003e — 100 ps edge-time adjustment, 3 ns minimum pulse width, per-pulse edge control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRBS PN3 to PN33\u003c\/strong\u003e — 1 µbps to 300 Mbps with adjustable edge time for serial-link and jitter-tolerance test.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e800 MHz hardware frequency counter\u003c\/strong\u003e — 100 mHz to 800 MHz, 8-digit, AC \/ DC \/ HF-reject coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver 200 built-in arbitrary waveforms\u003c\/strong\u003e — plus SPI, I²C, and UART digital-protocol output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10.1-inch capacitive touch display\u003c\/strong\u003e — 1280 × 800; direct parameter manipulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTG9354T+ Details\u003c\/h2\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eFour Equal-Performance Channels, 20 Vpp\u003c\/h3\u003e\n\u003cp\u003eFour independent channels in the standard configuration, every one delivering identical performance — there is no derated second bank. Each channel produces the full output envelope to 20 Vpp (high-Z) and can run fully independently, so clock, data, trigger, and stimulus can all originate from one instrument at full specification on every channel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9354T+ four equal-performance channels, 20 vpp\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFour equivalent-performance channels with full 20 Vpp output on every channel.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9354T+ channel coupling and merging\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFrequency, amplitude, and phase coupling across channels; outputs merge into composite signals.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eChannel Coupling and Merging\u003c\/h3\u003e\n\u003cp\u003eChannels can be freely coupled with configurable frequency, amplitude, and phase relationships (coupling ratio 0.0001 to 10,000), so a parameter change on one channel propagates to its coupled partners by a defined ratio and offset. Outputs can also be merged into arbitrary combinations — for example CH1 = CH1 + CH2 + CH3 + CH4 — producing summed and composite signals from a single instrument without external combiners.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eLow-Distortion Output and High SNR\u003c\/h3\u003e\n\u003cp\u003eDigital sampling produces sine, square, ramp, pulse, arbitrary, harmonic, noise, DC, and PRBS waveforms with low distortion and low jitter. Total harmonic distortion stays below 0.07% from DC to 20 kHz, with a spurious-free dynamic range to −80 dBc. A small signal superimposed on a large DC offset retains a high signal-to-noise ratio — useful when the stimulus must be quieter than the device under test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9354T+ low-distortion output and high snr\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTHD below 0.07% (DC to 20 kHz) with −80 dBc spurious-free dynamic range.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9354T+ wide-dynamic pulse with fast, independently adjustable edges\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEdge time adjustable in 100 ps steps; 3 ns minimum pulse width; per-pulse edge control.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eWide-Dynamic Pulse with Fast, Independently Adjustable Edges\u003c\/h3\u003e\n\u003cp\u003eThe pulse generator offers high-precision adjustable edge times with increments as fine as 100 ps and a minimum pulse width of 3 ns (Typ.), generating high harmonic content comparable to a dedicated pulse generator. Edge time can be set independently for each pulse, down to a 2 ns minimum, and pulse jitter stays at 200 ps across the operating range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003e15 Modulation Types in One Instrument\u003c\/h3\u003e\n\u003cp\u003eFifteen analog and digital modulation schemes are built in: AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, and PWM. Each channel supports independent or simultaneous internal\/external modulation and internal\/external\/manual triggering, alongside Linear\/Logarithmic\/List\/Step frequency sweep and N-cycle\/gate\/pulse-train burst.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9354T+ 15 modulation types in one instrument\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eFifteen modulation types covering analog and digital schemes, plus sweep and burst.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9354T+ multi-pulse and multi-tone generation\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eMulti-Pulse: 2–30 pulses with per-pulse edge control. Multi-Tone: 2–8 components.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eMulti-Pulse and Multi-Tone Generation\u003c\/h3\u003e\n\u003cp\u003eMulti-Pulse produces pulse trains of 2 to 30 pulses with independently adjustable edge times and high\/gap times for rapid, precise multi-pulse testing without custom code. Multi-Tone synthesizes 2 to 8 simultaneous frequency components, reproducing real-world multi-frequency signals for nonlinear-distortion analysis, wideband frequency-response work, and communication-system verification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003ch3\u003eSequence, Pattern, I\/Q, and Expression Functions\u003c\/h3\u003e\n\u003cp\u003eSequence chains up to 1,024 waveforms totalling 128 Mpts per channel with internal, external, manual, and timer start events for one-time loading of multiple test cases. Pattern outputs customizable code (NRZ\/RZ\/Manchester) at TTL, CMOS, ECL, and PECL logic standards. I\/Q generation delivers baseband output at any symbol rate to 1.25 GSa\/s. Expression builds complex waveforms directly from mathematical formulas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9354T+ sequence, pattern, i\/q, and expression functions\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eSequence, Pattern, I\/Q, and Expression — advanced waveform generation built in.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9354T+ built-in arbitrary editor, digital bus, and 800 mhz counter\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eBuilt-in arbitrary editor with PC-side editing; SPI\/I²C\/UART output; 800 MHz counter.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003ch3\u003eBuilt-In Arbitrary Editor, Digital Bus, and 800 MHz Counter\u003c\/h3\u003e\n\u003cp\u003eThe integrated arbitrary-waveform editor supports manual drawing, line drawing, and expression-based generation, and also runs on a PC over USB or LAN. Point-by-point output spans 8 pts to 128 Mpts with 16-bit vertical resolution. SPI, I²C, and UART digital-protocol output is built in, and a high-precision hardware frequency counter measures 100 mHz to 800 MHz with 8-digit resolution and selectable AC \/ DC \/ HF-reject coupling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe UTG9354T+ envelope — four equal-performance channels, 2.5 GSa\/s, 128 Mpts per channel, THD \u0026lt; 0.07%, 15-type modulation, the full advanced-function set, and a capacitive touch UI — targets benchtop work that needs genuine multi-channel stimulus, deep arbitrary support, or wide modulation coverage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-channel embedded development\u003c\/strong\u003e — four matched channels drive clock, data, trigger, and stimulus simultaneously from one instrument, conserving bench space while keeping every channel at full performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRF and communications stimulus\u003c\/strong\u003e — 3FSK, 4FSK, BPSK, QPSK, OSK, QAM digital modulation and SUM \/ DSB-AM analog modulation drive component characterization and protocol development across the full output range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed digital and serial-link test\u003c\/strong\u003e — fast adjustable edges with 100 ps steps, PRBS PN3 to PN33, and SPI \/ I²C \/ UART protocol output for interface and jitter-tolerance work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio and instrumentation testing\u003c\/strong\u003e — THD below 0.07% from DC to 20 kHz when characterizing op-amp distortion, ADC noise floors, and audio-band response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-form arbitrary playback\u003c\/strong\u003e — up to 128 Mpts per channel holds extended protocol streams, sensor-emulation traces, and complex composite waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/Q and modulated-carrier work\u003c\/strong\u003e — baseband I\/Q at any symbol rate to 1.25 GSa\/s for communication-system verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated test (ATE)\u003c\/strong\u003e — LAN\/USB remote control and instrument-manager software for synchronized multi-instrument benches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003ch3\u003eIncluded with Every Unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord conforming to destination country standard\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003eBNC-to-BNC cable × 4 (UT-L45)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat does “2.5 GSa\/s with 2× interpolation” mean in practice?\u003c\/p\u003e\n\u003cp\u003eThe DAC runs at a native rate, and a digital interpolation filter inserts estimated samples to produce a 2.5 GSa\/s effective output stream. The reconstruction filter then sees a higher-rate stream and passes more high-frequency signal content with less alias distortion, giving finer detail in the upper portion of the output range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDo all four channels run at full performance simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes. The four channels are equal-performance — each delivers the full output envelope to 20 Vpp (high-Z) independently, with no derating when multiple channels are active. Channels can also be coupled by frequency \/ amplitude \/ phase ratio or merged into composite outputs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat modulation, sweep, and burst envelope does the UTG9354T+ cover?\u003c\/p\u003e\n\u003cp\u003eModulation: 15 types — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM. Sweep: Linear, Logarithmic, List, Step with internal \/ external \/ manual triggers. Burst: N-cycle (1 to 1,000,000 cycles), gate, and pulse-train.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat advanced waveform functions are included?\u003c\/p\u003e\n\u003cp\u003eMulti-Pulse (2 to 30 pulses, per-pulse edge \/ high \/ gap times), Multi-Tone (2 to 8 components), Sequence (up to 1,024 waveforms, 128 Mpts per channel), Pattern (NRZ \/ RZ \/ Manchester at TTL, CMOS, ECL, PECL levels), I\/Q (baseband to 1.25 GSa\/s), and Expression (formula-defined waveforms) are all standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat digital-protocol outputs are supported?\u003c\/p\u003e\n\u003cp\u003eSPI, I²C, and UART are built in. SPI and I²C run a 1 Hz to 50 MHz clock with up to 2,048-byte data depth; UART supports custom baud rates from 1 to 1,000,000 with configurable data, stop, and parity bits — useful for driving and emulating embedded serial buses directly from the generator.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_four-channel_output.png\" alt=\"UTG9354T+ four equal-performance channels, 20 vpp\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFour independent equal-performance channels, 20 Vpp on every channel\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_channel_coupling_merge.png\" alt=\"UTG9354T+ channel coupling and merging\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eChannel coupling and merging — ratio-linked parameters and combined outputs\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_low_distortion_output.png\" alt=\"UTG9354T+ low-distortion output and high snr\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eLow-distortion continuous-wave output with high SNR on large DC offsets\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_pulse_wave.png\" alt=\"UTG9354T+ wide-dynamic pulse with fast, independently adjustable edges\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eWide-dynamic pulse output with fine, independently adjustable edge times\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_modulation_types.png\" alt=\"UTG9354T+ 15 modulation types in one instrument\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eFifteen modulation types — analog and digital — with sweep and burst\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_multi_pulse.png\" alt=\"UTG9354T+ multi-pulse and multi-tone generation\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eMulti-Pulse and Multi-Tone generation for complex timing and spectral test\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_sequence_dynamic_testing_c274c9bd-1488-4a0c-9e5e-ead5a55261fe.png\" alt=\"UTG9354T+ sequence, pattern, i\/q, and expression functions\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eAdvanced functions: Sequence, Pattern, I\/Q, and Expression-based waveforms\u003c\/span\u003e\n\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/UTG9000T_plus_edit_arb_1.png\" alt=\"UTG9354T+ built-in arbitrary editor, digital bus, and 800 mhz counter\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eBuilt-in arbitrary editor, digital-bus output, and 100 mHz–800 MHz hardware counter\u003c\/span\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax sine frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax square frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pulse frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, independent and equal-performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 GSa\/s (2× interpolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVertical resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit (including sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary waveform length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 pts to 128 Mpts\/CH (expandable to 256 Mpts\/CH with PC software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-in arbitrary waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver 200, non-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary file storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 GB internal for arbitrary-waveform files (.bsv\/.csv)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard waveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine, Square, Ramp, Pulse, Harmonic, Noise, PRBS, DC, Arbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModulation types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 — AM, FM, PM, DSB-AM, ASK, FSK, PSK, 3FSK, 4FSK, BPSK, QPSK, OSK, SUM, QAM, PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFM frequency offset\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 μHz to 175 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 μHz to 175 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic distortion (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC to 10 MHz ≤ −65 dBc; 10–100 MHz ≤ −60 dBc; 100–150 MHz ≤ −50 dBc; 150–200 MHz ≤ −40 dBc; 200–350 MHz ≤ −30 dBc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-tone frequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kHz to 350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/Q center frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise bandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mHz to 350 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRamp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µHz to 20 MHz, symmetry 0.00% to 100.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear, Logarithmic, List, Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurst modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-cycle, Gate, Pulse-train\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdvanced functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Pulse, Multi-Tone, Sequence, Pattern, I\/Q, Expression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital-protocol output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPI, I²C, UART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency counter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mHz to 800 MHz hardware frequency counter, AC \/ DC \/ HF-reject coupling, 8-digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (50 Ω)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mVpp to 10 Vpp (50 Ω, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput amplitude (high-Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mVpp to 20 Vpp (high-Z, ≤ 40 MHz band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal harmonic distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.07% (0 dBm, DC to 20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpurious-free dynamic range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−80 dBc spurious-free dynamic range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ −130 dBc\/Hz @ 10 kHz offset (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 ps (1 Vpp, 50 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArbitrary jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSquare rise\/fall time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 ns (Typ., square)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum pulse width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 ns (Typ.); edge step to 100 ps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePRBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePN3 to PN33, 1 µbps to 300 Mbps; edge 2 ns to 1 ks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude flatness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 10 MHz ±0.1 dB; ≤ 60 MHz ±0.2 dB; ≤ 80 MHz ±0.4 dB (Typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz, ±0.5 ppm initial accuracy (25°C); ±1 ppm aging (first year)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.1-inch capacitive touch, 1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Host, USB Device, LAN; 10 MHz reference in\/out; external trigger in\/out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-circuit protection; overload auto-disables waveform output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VACrms (±10%), 50\/60 Hz; \u0026lt; 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤ 90% RH below +35°C; ≤ 60% RH +35°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361 mm × 209 mm × 106 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus; EN 61010-1, EN 61326-1 EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=124\"\u003eUTG9354T+ Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368466706683,"sku":"181300100145X","price":4999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTG9000T_-1_27b82cb6-1739-4cd6-9275-aad04656d4dc.png?v=1792619300"},{"product_id":"uts7000a-p40-40-ghz-preamplifier-option-for-uts7040a","title":"UTS7000A-P40 40 GHz Preamplifier Option for UTS7040A","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS7000A-P40\u003c\/strong\u003e is the 40 GHz preamplifier option for the UTS7040A and UTS7040A–NB signal analyzer chassis. The option engages a low-noise front-end amplifier ahead of the input mixer, lowering displayed average noise level (DANL) by roughly 13 to 17 dB across the chassis frequency range and improving sensitivity for weak-signal measurement.\u003c\/p\u003e\n\u003cp\u003eThe preamplifier is activated by software license against the chassis serial number. Once installed, Preamp On\/Off is toggled from the chassis menu — no separate hardware is shipped, no chassis disassembly is required, and no service call is needed. The license is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDANL improvement of ≈13 to 17 dB\u003c\/strong\u003e — Across the chassis frequency range, with the largest gains in the mid-band where the chassis noise floor is highest\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreamp On\/Off menu toggle\u003c\/strong\u003e — Engagement is software-controlled from the front panel; switch in for weak-signal measurement, switch out for higher-power measurements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable frequency range\u003c\/strong\u003e — 100 kHz to 40 GHz (chassis-capped); the option spec covers 100 kHz to 40 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePer-band noise figure characterization\u003c\/strong\u003e — Datasheet-published DANL with Preamp On at every chassis-relevant band\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhat the Preamplifier Adds\u003c\/h2\u003e\n\u003cp\u003eThe preamplifier option lowers the chassis noise floor for weak-signal measurement. Values below are taken from the UTS7000A Series datasheet.\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:42%\"\u003e\n\u003ccol style=\"width:58%\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable frequency range\u003c\/td\u003e\n\u003ctd\u003e100 kHz to 40 GHz (chassis-capped from option spec of 100 kHz to 40 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivation mechanic\u003c\/td\u003e\n\u003ctd\u003eSoftware license against chassis serial; installed via chassis Option Install menu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngagement\u003c\/td\u003e\n\u003ctd\u003ePreamp On \/ Preamp Off toggle from chassis menu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" class=\"cohort-label\"\u003e\u003cstrong\u003eDisplayed Average Noise Level (DANL) — Preamp On vs Off (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency band\u003c\/th\u003e\n\u003cth\u003ePreamp Off → Preamp On\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MHz to 20 MHz\u003c\/td\u003e\n\u003ctd\u003e−145 dBm → −160 dBm (≈15 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 MHz to 1.5 GHz\u003c\/td\u003e\n\u003ctd\u003e−145 dBm → −162 dBm (≈17 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5 GHz to 3 GHz\u003c\/td\u003e\n\u003ctd\u003e−143 dBm → −158 dBm (≈15 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.5 GHz to 7.5 GHz\u003c\/td\u003e\n\u003ctd\u003e−139 dBm → −152 dBm (≈13 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9.5 GHz to 12.3 GHz\u003c\/td\u003e\n\u003ctd\u003e−136 dBm → −152 dBm (≈16 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15.5 GHz to 19.3 GHz\u003c\/td\u003e\n\u003ctd\u003e−134 dBm → −150 dBm (≈16 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22.8 GHz to 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003e−133 dBm → −148 dBm (≈15 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e26.5 GHz to 32 GHz\u003c\/td\u003e\n\u003ctd\u003e−128 dBm → −144 dBm (≈16 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e32 GHz to 40 GHz\u003c\/td\u003e\n\u003ctd\u003e−124 dBm → −140 dBm (≈16 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" class=\"cohort-label\"\u003e\u003cstrong\u003e1 dB Gain Compression Point — Preamp On (input mixer)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency band\u003c\/th\u003e\n\u003cth\u003eCompression point\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 MHz to 7.5 GHz\u003c\/td\u003e\n\u003ctd\u003e−15 dBm (Nom.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7.5 GHz to 26.5 GHz\u003c\/td\u003e\n\u003ctd\u003e−19 dBm (Nom.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e26.5 GHz to 40 GHz\u003c\/td\u003e\n\u003ctd\u003e−32 dBm (Nom.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe preamplifier earns its place in the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeak-signal capture near the chassis noise floor\u003c\/strong\u003e — Signals at or below the Preamp Off DANL become visible and measurable once the front-end gain is engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI pre-compliance and emissions survey\u003c\/strong\u003e — Low ambient emissions across the 40 GHz range become measurable above the noise floor for source-of-emission troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase-noise and spectral-purity measurement of low-power oscillators\u003c\/strong\u003e — Improved SNR at the carrier and offset frequencies tightens phase-noise floor measurements on weak sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAntenna pattern and gain testing\u003c\/strong\u003e — Far-field power measurements and sidelobe characterization where the received signal sits well below the unamplified noise floor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable-loss and link-budget characterization\u003c\/strong\u003e — Measuring small signals at the far end of long cable runs without external amplification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor high-power measurement (signals above approximately −15 dBm at the input mixer), toggle Preamp Off; the front-end amplifier compresses earlier than the chassis input mixer alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThe 40 GHz preamplifier license is bandwidth-matched to the UTS7040A chassis tier. Compatibility:\u003c\/p\u003e\n\u003ctable class=\"product-spec-table\" style=\"table-layout:fixed;width:100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width:55%\"\u003e\n\u003ccol style=\"width:45%\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eChassis variant\u003c\/th\u003e\n\u003cth\u003eOption install\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" class=\"cohort-label\"\u003e\u003cstrong\u003e40 GHz chassis tier\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7040A — 2 Hz to 40 GHz, Wide-Band (40 MHz analysis)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\nUTS7040A–NB — 2 Hz to 40 GHz, Narrow-Band (20 MHz analysis)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEach preamplifier license is keyed to its chassis frequency tier and is not interchangeable across tiers. Customers needing preamplification at a different bandwidth tier should select the corresponding model: P13 (13.6 GHz), P26 (26.5 GHz), P32 (32 GHz), or P40 (40 GHz).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eIs the UTS7000A-P40 a software license or a hardware option?\u003c\/h3\u003e\n\u003cp\u003eThe preamplifier is activated by software license. The amplifier hardware is present in the chassis; the license enables its use. Installation is via the chassis Option Install menu against the chassis serial number — no hardware is shipped separately and no service call is required.\u003c\/p\u003e\n\u003ch3\u003eHow is the license installed?\u003c\/h3\u003e\n\u003cp\u003eThe license is purchased against the chassis serial number, registered on the UNI-T website to obtain the license file, and installed via the chassis Option Install menu using a USB storage device. Refer to the UTS7040A User Manual for the full step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eCan the preamplifier be added to an existing UTS7040A or UTS7040A–NB in the field?\u003c\/h3\u003e\n\u003cp\u003eYes. Because activation is by software license, the option can be added at any time after the chassis is in the field. There is no hardware retrofit, no chassis disassembly, and no service call. The chassis must be the matching frequency tier (40 GHz).\u003c\/p\u003e\n\u003ch3\u003eCan the UTS7000A-P40 license be moved to a different chassis?\u003c\/h3\u003e\n\u003cp\u003eNo. The license is keyed to the chassis serial number it is registered against. It cannot be transferred to a different chassis. If a second chassis needs preamplification, a second license must be purchased.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that remains active for the life of the instrument. There are no subscription fees, no annual renewals, and no expiration date.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=117\"\u003eUTS7000A-P40 Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368466772219,"sku":"191502400032","price":3299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS7000A-P40.png?v=1792619299"},{"product_id":"uts5000a-pnm-phase-noise-measurement-option","title":"UTS5000A-PNM Phase Noise Measurement Option","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe UTS5000A-PNM adds dedicated phase noise measurement for oscillators, synthesizers, and clock sources — phase noise vs. offset frequency with high sensitivity. The option is enabled by a software license keyed to the spectrum analyzer's serial number and is permanent for the life of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"product-key-features\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Noise vs. Offset\u003c\/strong\u003e — Single-sideband phase noise from Hz to MHz offsets in one sweep.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto Carrier Detection\u003c\/strong\u003e — Automatically identifies the carrier frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Phase Noise\u003c\/strong\u003e — Calculates jitter over a specified offset range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpur Identification\u003c\/strong\u003e — Identifies discrete spurious signals in the phase noise spectrum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime License Activation\u003c\/strong\u003e — activate once, owned for the life of the instrument. No subscriptions, no renewals, no maintenance fees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eWhen You Need This Option\u003c\/h2\u003e\n\u003cp\u003eThe option fits the following workflows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOscillator Characterization\u003c\/strong\u003e — Measure TCXO\/OCXO phase noise for PLL and data converter requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynthesizer Validation\u003c\/strong\u003e — Verify synthesizer phase noise profile at critical offsets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003eThis option is compatible with all UTS5000A Series spectrum analyzers. The same capability is offered on other UNI-T spectrum analyzer families: UTS3000A, UTS7000A.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eHow is this option activated?\u003c\/h3\u003e\n\u003cp\u003eThe option is enabled by a software license keyed to the spectrum analyzer's serial number. After purchase, the license is registered on the UNI-T website to generate the license file, which is then loaded onto the spectrum analyzer from a USB drive through the option-install menu. Refer to the spectrum analyzer's user manual for the step-by-step procedure.\u003c\/p\u003e\n\u003ch3\u003eIs the license permanent, or does it require renewal?\u003c\/h3\u003e\n\u003cp\u003eThe license is permanent — a one-time purchase that stays active for the life of the instrument. No subscriptions, no annual renewals, and no expiration.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":68368466739451,"sku":"191501700003","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/files\/UTS5000A-PNM_236e4217-7a03-4b2a-892d-9bc9565681c1.png?v=1792619299"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/6622\/collections\/UTG2000X-1_ca8c02a5-1a54-4146-b147-b2c7b5a74641.png?v=1792619598","url":"https:\/\/anatekinstruments.com\/collections\/unitrend-instruments.oembed","provider":"Alltronics LLC","version":"1.0","type":"link"}